Radiology, Vol 122, 399-403, Copyright © 1977 by Radiological Society of North America
ARTICLES |
ML Goris, SG Daspit, JP Walter, J McRae and J Lamb
A method for the evaluation of regional lung ventilation using 81mKr eluted from a rubidium generator is described. The tracer distribution at equilibrium is a function of regional ventilation, not of volumes. The study can be performed on a wide range of patients, including unconscious and mechanically ventilated patients, and can be performed immediately following or concurrently with a perfusion study. Thus, precisely comparable ventilation and perfusion images can be obtained.
This article has been cited by other articles:
![]() |
S. R. Thomas MIRD Pamphlet No. 18: Administered Cumulated Activity for Ventilation Studies J. Nucl. Med., March 1, 2001; 42(3): 520 - 526. [Abstract] [Full Text] |
||||
![]() |
W. Seed Pulmonary embolism: Part 2 Diagnostic methods and management Vascular Medicine, September 1, 1991; 2(2): 121 - 136. [PDF] |
||||