Radiology, Vol 122, 731-737, Copyright © 1977 by Radiological Society of North America
ARTICLES |
SR Thomas, HR Maxon, JG Kereiakes and EL Saenger
A quantitative technique is described which allows the physician to predict more accurately whether a recurrent or metastatic well- differentiated thyroid carcinoma is amenable to radioiodine-131 therapy or is better treated by other means. A calibrated uptake probe and scaler system is used to obtain conjugate view (i.e., diametrically opposed) counting rates for both the whole body and for any areas of abnormal uptake (lesion) at 24,48 annd 72 hours following the administration of 2 mCi 131l. Quantitative calculations accounting for patient attenuation, lesion size and geometrical factors then provide a determination of the lesion uptake as well as the effective half-life of 131l in the lesion. The radiation dose which would be delivered to the lesion by a given therapeutic amount of 131l may then be calculated to help determine the desirability of 131l treatment. The results of patient studies indicate the potential benefit of such quantitative evaluation.
This article has been cited by other articles:
![]() |
C. S. Bal, A. Kumar, and G. S. Pant Radioiodine Dose for Remnant Ablation in Differentiated Thyroid Carcinoma: A Randomized Clinical Trial in 509 Patients J. Clin. Endocrinol. Metab., April 1, 2004; 89(4): 1666 - 1673. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Lassmann, M. Luster, H. Hanscheid, and C. Reiners Impact of 131I Diagnostic Activities on the Biokinetics of Thyroid Remnants J. Nucl. Med., April 1, 2004; 45(4): 619 - 625. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Sisson and J. E. Carey Thyroid Carcinoma with High Levels of Function: Treatment with 131I J. Nucl. Med., June 1, 2001; 42(6): 975 - 983. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. M. Kaptein, H. Levenson, M. E. Siegel, M. Gadallah, and M. Akmal Radioiodine Dosimetry in Patients with End-Stage Renal Disease Receiving Continuous Ambulatory Peritoneal Dialysis Therapy J. Clin. Endocrinol. Metab., September 1, 2000; 85(9): 3058 - 3064. [Abstract] [Full Text] |
||||
![]() |
M. C. Graham, H. I. Scher, G.-B. Liu, S. D-J. Yeh, T. Curley, F. Daghighian, S. J. Goldsmith, and S. M. Larson Rhenium-186-labeled Hydroxyethylidene Diphosphonate Dosimetry and Dosing Guidelines for the Palliation of Skeletal Metastases from Androgen-independent Prostate Cancer Clin. Cancer Res., June 1, 1999; 5(6): 1307 - 1318. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |