Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kuhns, L. R.
Right arrow Articles by Borlaza, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kuhns, L. R.
Right arrow Articles by Borlaza, G.

Radiology, Vol 135, 763-764, Copyright © 1980 by Radiological Society of North America


ARTICLES

The "twinkling star" sign: an aid in differentiating pulmonary vessels from pulmonary nodules on computed tomograms

LR Kuhns and G Borlaza

Radial linear artifacts are visualized on computed tomographic (CT) images of pulmonary vessels, whereas pulmonary nodules are usually not associated with these artifacts. In vitro evidence indicates that pulsation of an object of relatively high density compared to surrounding structures enhances production of these artifacts.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
H. I. Ha, H. W. Goo, J. B. Seo, J.-W. Song, and J. S. Lee
Effects of high-resolution CT of the lung using partial versus full reconstruction on motion artifacts and image noise.
Am. J. Roentgenol., September 1, 2006; 187(3): 618 - 622.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. K. Hofmann, K. H. Zou, P. Costello, and U. J. Schoepf
Electrocardiographically Gated 16-Section CT of the Thorax: Cardiac Motion Suppression
Radiology, December 1, 2004; 233(3): 927 - 933.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Boehm, J. K. Willmann, P. R. Hilfiker, D. Weishaupt, B. Seifert, D. W. Crook, B. Marincek, and S. Wildermuth
Thin-Section CT of the Lung: Does Electrocardiographic Triggering Influence Diagnosis?
Radiology, November 1, 2003; 229(2): 483 - 491.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
U. J. Schoepf, C. R. Becker, R. D. Bruening, T. Helmberger, A. Staebler, P. Leimeister, and M. F. Reiser
Electrocardiographically Gated Thin-Section CT of the Lung
Radiology, September 1, 1999; 212(3): 649 - 654.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1980 by the Radiological Society of North America.