Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Riederer, S. J.
Right arrow Articles by Djang, W. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Riederer, S. J.
Right arrow Articles by Djang, W. T.

Radiology, Vol 146, 349-354, Copyright © 1983 by Radiological Society of North America


ARTICLES

The application of matched filtering to x-ray exposure reduction in digital subtraction angiography: clinical results

SJ Riederer, DR Enzmann, AL Hall, NJ Pelc and WT Djang

This new digital fluorography processing method of matched filtering generates a set of images that have been acquired at continuous video- frame rates (30 per second) over the temporal extent of the bolus (10 seconds), and it combines them to produce the equivalent of a single digital subtraction angiography (DSA) image. Because of the extensive temporal averaging used, the method can provide substantial x-ray exposure reduction per run as compared with conventional techniques for an equivalent signal-to-noise ratio in the final image. The matched filtering technique was compared with conventional pulsed (one per second) DSA images of both extracranial and intracranial arteries, and the results are presented. Matched filtered images provided image quality that was equivalent to that of conventional DSA images at about one-fourth the patient exposure per run for both carotid artery and cerebral vessel studies. Despite long integration times, patient motion irretrievably corrupted image quality in only two of five carotid artery studies and in none of three intracranial studies. Compensation for patient motion is demonstrated, and additional applications and limitations of the technique are discussed.