Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zwiebel, W. J.
Right arrow Articles by Strother, C. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zwiebel, W. J.
Right arrow Articles by Strother, C. M.

Radiology, Vol 149, 523-532, Copyright © 1983 by Radiological Society of North America


ARTICLES

Correlation of high-resolution, B-mode and continuous-wave Doppler sonography with arteriography in the diagnosis of carotid stenosis

WJ Zwiebel, CW Austin, JF Sackett and CM Strother

One hundred thirty-one carotid bifurcations in 73 symptomatic patients were prospectively studied with high-resolution, B-mode sonography (HRS) and continuous-wave Doppler ultrasound (CWD). Twenty-three bifurcations were studied because of asymptomatic bruits, 30 for transient ischemic attacks, and 36 for focal or nonfocal symptoms or signs suggesting occlusive disease. The remaining 42 bifurcations were asymptomatic, with symptoms or signs confined to the contralateral bifurcation. Findings in the common, external, and internal carotid arteries (total, 393 vessels) were tabulated separately for plaque severity (HRS), ulceration (HRS), and degree of occlusion (HRS and CWD). HRS correctly estimated plaque severity in 67% of vessels, with 13% overestimated and 20% underestimated. HRS was only 44% sensitive for detection of 81 angiographically demonstrated ulcers. Among 187 occlusive lesions (ranges, less than 50%, greater than or equal to 50%, less than 70%, greater than or equal to 70% decrease in diameter or complete occlusion) HRS correctly estimated luminal narrowing in 62%, CWD in 30%, and HRS plus CWD in 70%. Among greater than 50% occlusive lesions, HRS was correct in 48%, CWD in 59%, and HRS plus CWD in 69%. These results suggest that (a) HRS is not accurate for diagnosis of ulceration, (b) Doppler and B-mode combined are more accurate than separate use of either procedure for evaluation of occlusive lesions, and (c) the level of accuracy in evaluating plaque and stenosis provides a general estimation of severity of disease but does not allow for precise diagnosis.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
G. M. Hathout, J. R. Fink, S. M. El-Saden, and E. G. Grant
Sonographic NASCET Index: A New Doppler Parameter for Assessment of Internal Carotid Artery Stenosis
AJNR Am. J. Neuroradiol., January 1, 2005; 26(1): 68 - 75.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. G. Grant, C. B. Benson, G. L. Moneta, A. V. Alexandrov, J. D. Baker, E. I. Bluth, B. A. Carroll, M. Eliasziw, J. Gocke, B. S. Hertzberg, et al.
Carotid Artery Stenosis: Gray-Scale and Doppler US Diagnosis--Society of Radiologists in Ultrasound Consensus Conference
Radiology, November 1, 2003; 229(2): 340 - 346.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
G. M Hathout, M. J. Duh, and S. M. El-Saden
Accuracy of Contrast-Enhanced MR Angiography in Predicting Angiographic Stenosis of the Internal Carotid Artery: Linear Regression Analysis
AJNR Am. J. Neuroradiol., October 1, 2003; 24(9): 1747 - 1756.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. G. Grant, A. J. Duerinckx, S. M. El Saden, M. L. Melany, G. M. Hathout, P. T. Zimmerman, A. K. Marumoto, S. N. Cohen, and J. D. Baker
Ability to Use Duplex US to Quantify Internal Carotid Arterial Stenoses: Fact or Fiction?1
Radiology, January 1, 2000; 214(1): 247 - 252.
[Abstract] [Full Text]


Home page
ANGIOLOGYHome page
L. Birincioglu, K. Arda, H. Bardakci, K. Ozberk, M. Bayazlt, T. Cumhur, O. Tasdemir, and K. Bayazit
Carotid Disease in Patients Scheduled for Coronary Artery Bypass: Analysis of 678 Patients
Angiology, January 1, 1999; 50(1): 9 - 19.
[Abstract] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
N. Labropoulos, A. Androulakis, R. Allan, A. D. Giannoukas, E. Touloupakis, T. Tegos, A. Al Kutoubi, and A. N. Nicolaides
Value of Color Flow Duplex Imaging in Detection of Subtotal and Total Internal Carotid Artery Occlusion
Vascular and Endovascular Surgery, November 1, 1997; 31(6): 775 - 779.
[Abstract] [PDF]


Home page
StrokeHome page
R. Kagawa, K. Moritake, T. Shima, and Y. Okada
Validity of B-Mode Ultrasonographic Findings in Patients Undergoing Carotid Endarterectomy in Comparison With Angiographic and Clinicopathologic Features
Stroke, April 1, 1996; 27(4): 700 - 705.
[Abstract] [Full Text]


Home page
StrokeHome page
E.B. Ringelstein
Skepticism Toward Carotid Ultrasonography : A Virtue, an Attitude, or Fanaticism?
Stroke, October 1, 1995; 26(10): 1743 - 1746.
[Full Text]


Home page
ANGIOLOGYHome page
C. R. Gomez
Mapping the Cerebral Blood Vessels With High-Field MRI: Technical and Anatomic Review
Angiology, May 1, 1989; 40(5): 436 - 442.
[Abstract] [PDF]


Home page
ANGIOLOGYHome page
U. Senin, L. Parnetti, M. Mercuri, G. Lupattelli, A. Susta, and G. Ciuffetti
Evolutionary Trends in Carotid Atherosclerotic Plaques: Results of a Two-Year Follow-up Study Using an Ultrasound Imaging System
Angiology, May 1, 1988; 39(5): 429 - 436.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1983 by the Radiological Society of North America.