Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stark, D. D.
Right arrow Articles by Ferrucci, J. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stark, D. D.
Right arrow Articles by Ferrucci, J. T., Jr

Radiology, Vol 159, 365-370, Copyright © 1986 by Radiological Society of North America


ARTICLES

Detection of hepatic metastases: analysis of pulse sequence performance in MR imaging

DD Stark, J Wittenberg, RR Edelman, MS Middleton, S Saini, RJ Butch, TJ Brady and JT Ferrucci Jr

Forty-three patients with liver metastases were imaged using 14 different pulse sequences (average, 7.5 sequences per patient) to allow direct comparison of their performance. "T2-weighted" spin-echo (SE) images, "T1-weighted" inversion recovery (IR) images, and "T1-weighted" SE images were obtained using a wide range of timing parameters. Pulse sequence performance was quantitated by measuring liver signal-to-noise (S/N) ratios and cancer-liver signal difference-to-noise (SD/N) ratios. Data were standardized to reflect a constant imaging time of 9 minutes for all pulse sequences. The SE 2,000/120 (TR [repetition time]/TE [echo time]) sequence resulted in the greatest SD/N ratio of the T2- weighted SE sequences but also yielded the low S/N ratios, poor anatomic resolution, and motion artifacts common to all T2-weighted SE images. IR sequence images were also sensitive to motion artifacts because of the use of a long TR (1,500 msec). Short TR/TE T1-weighted SE sequences (SE 260/18) had the greatest SD/N ratio (P less than .05), S/N ratio, and anatomic resolution. Furthermore, extensive signal averaging appears to be a powerful solution to all types of motion artifacts in the abdomen.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
M. L. Lauzon, H. Mahallati, and R. Frayne
Time-efficient breath-hold abdominal MRI at 3.0 T.
Am. J. Roentgenol., September 1, 2006; 187(3): 649 - 657.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
W. P. Hosch, S. M. Schmidt, S. Plaza, C. Dechow, J. Schmidt, S. Ley, G. W. Kauffmann, and J. Hansmann
Comparison of CT during arterial portography and MR during arterial portography in the detection of liver metastases.
Am. J. Roentgenol., June 1, 2006; 186(6): 1502 - 1511.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1986 by the Radiological Society of North America.