Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Teitelbaum, G. P.
Right arrow Articles by Bradley, W. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Teitelbaum, G. P.
Right arrow Articles by Bradley, W. G., Jr

Radiology, Vol 168, 713-719, Copyright © 1988 by Radiological Society of North America


ARTICLES

Low-artifact intravascular devices: MR imaging evaluation

GP Teitelbaum, HV Ortega, S Vinitski, H Stern, JS Tsuruda, DG Mitchell, MD Rifkin and WG Bradley Jr
Huntington Medical Research Institute, Pasadena, Calif.

Flow-phantom magnetic resonance (MR) imaging, with use of both spin- echo (SE) and gradient-echo (GRE) techniques at 1.5 T, was performed on the percutaneous Greenfield (beta-III titanium alloy [TMA wire]), Amplatz (MP32-N alloy), and Simon nitinol filters and TMA wire facsimiles of the bird's nest, Gunther, new retrievable, and Amplatz vena caval filters. SE imaging allowed detection of thrombi as small as 5 X 5 mm trapped within the percutaneous Greenfield, Simon nitinol, and TMA-wire facsimile filters; with the MP32-N Amplatz filter, a larger volume of thrombus (10 X 20-mm clots) was necessary for clot detection. GRE imaging allowed detection of intraluminal tilting of the percutaneous Greenfield and facsimile Amplatz (TMA-wire) filters. GRE imaging was useful for demonstrating postfilter turbulence due to clots, which was greatest for the Amplatz filter. Imaging of facsimile vascular devices made of tantalum or TMA wire did not cause the severe "black-hole" MR artifacts typical of the stainless-steel devices. SE and GRE imaging were very useful for determining caval patency in two patients with previously placed Mobin-Uddin filters. Noninvasive MR evaluation of blood vessels in the presence of a variety of low- artifact intravascular devices appears feasible.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
I. Saatci, H. S. Cekirge, E. F. M. Ciceri, M. E. Mawad, A. G. Pamuk, and A. Besim
CT and MR Imaging Findings and Their Implications in the Follow-up of Patients with Intracranial Aneurysms Treated with Endosaccular Occlusion with Onyx
AJNR Am. J. Neuroradiol., April 1, 2003; 24(4): 567 - 578.
[Abstract] [Full Text] [PDF]


Home page
J Intensive Care MedHome page
M. B. Streiff
Vena Caval Filters: A Review for Intensive Care Specialists
J Intensive Care Med, March 1, 2003; 18(2): 59 - 79.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1988 by the Radiological Society of North America.