Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wandtke, J. C.
Right arrow Articles by McFaul, J. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wandtke, J. C.
Right arrow Articles by McFaul, J. A.

Radiology, Vol 169, 23-27, Copyright © 1988 by Radiological Society of North America


ARTICLES

Improved pulmonary nodule detection with scanning equalization radiography

JC Wandtke, DB Plewes and JA McFaul
Department of Diagnostic Radiology, University of Rochester Medical Center, NY 14642.

The potential for improved pulmonary nodule detection with scanning equalization radiography (SER) was evaluated by means of observer performance testing during the interpretation of posteroanterior conventional radiographs and SER images of an anthropomorphic chest phantom with simulated nodules. A test set of 200 conventional and 200 SER radiographs of phantoms containing either one nodule or none was interpreted by four radiologists attempting to detect a nodule and indicate a confidence value. Their ability to detect nodules positioned over the lung was slightly improved with SER compared with conventional radiography (sensitivity, .56 vs .70); for nodules over the mediastinum or diaphragmatic areas, it was much improved (sensitivity, .29 vs .64). The results were also analyzed with receiver-operating characteristic methods, which revealed a significant improvement in lesion detect- ability over the thicker body parts with SER images. The capability of equalized chest radiographs to provide improved lesion detectability suggests that SER may set a new standard for film-based chest radiography and have a large clinical application.


This article has been cited by other articles:


Home page
RadiologyHome page
H. P. McAdams, E. Samei, J. Dobbins III, G. D. Tourassi, and C. E. Ravin
Recent Advances in Chest Radiography
Radiology, December 1, 2006; 241(3): 663 - 683.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1988 by the Radiological Society of North America.