Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vlasbloem, H.
Right arrow Articles by Kool, L. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vlasbloem, H.
Right arrow Articles by Kool, L. J.

Radiology, Vol 169, 29-34, Copyright © 1988 by Radiological Society of North America


ARTICLES

AMBER: a scanning multiple-beam equalization system for chest radiography

H Vlasbloem and LJ Kool
Optical Industries Oldelft Delft, The Netherlands.

Conventional chest radiography is limited by the small useful exposure range of radiographic film. The wide variation in absorption thickness of different parts of the chest results in areas of under- and over- exposure. An advanced multiple-beam equalization system, AMBER, controls local exposure delivered to the film. The system has a row of 20 modulators in front of the x-ray tube, each able to change the height of the local slit beam during scanning. Changes are made in response to measurements from a linear detector array in front of the film cassette. This array consists of 20 individually functioning detectors coupled through electronic feedback loops to the 20 modulators. A scan is obtained in 0.8 second with a local exposure time of approximately 50 msec. AMBER results in radiographs with significantly improved exposure of the mediastinum without overexposure of the lungs.


This article has been cited by other articles:


Home page
RadiologyHome page
W. J. H. Veldkamp, L. J. M. Kroft, B. J. A. Mertens, and J. Geleijns
Digital Slot-Scan Charge-coupled Device Radiography versus AMBER and Bucky Screen-Film Radiography: Comparison of Image Quality in a Phantom Study
Radiology, June 1, 2005; 235(3): 857 - 866.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. J. M. Kroft, J. Geleijns, B. J. A. Mertens, W. J. H. Veldkamp, H. M. Zonderland, and A. de Roos
Digital Slot-Scan Charge-coupled Device Radiography versus AMBER and Bucky Screen-Film Radiography for Detection of Simulated Nodules and Interstitial Disease in a Chest Phantom
Radiology, April 1, 2004; 231(1): 156 - 163.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. R. Heitzman
Thoracic Radiology: The Past 50 Years
Radiology, February 1, 2000; 214(2): 309 - 313.
[Abstract] [Full Text]


Home page
RadiologyHome page
S. Molloi, A. Van Drie, and F. Wang
X-ray Beam Equalization: Feasibility and Performance of an Automated Prototype System in a Phantom and Swine
Radiology, December 1, 2001; 221(3): 668 - 675.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1988 by the Radiological Society of North America.