Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schaefer, C. M.
Right arrow Articles by Rubens, J. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schaefer, C. M.
Right arrow Articles by Rubens, J. R.

Radiology, Vol 178, 169-173, Copyright © 1991 by Radiological Society of North America


ARTICLES

Mediastinal abnormalities: detection with storage phosphor digital radiography

CM Schaefer, R Greene, DA Hall, SR Lindemann, HJ Llewellyn, KA McCarthy, ER Pile- Spellman and JR Rubens
Department of Radiology I, Medizinische Hochschule Hannover, Federal Republic of Germany.

Conventional film radiography (FR) and six postprocessing algorithms of isodose storage phosphor digital radiography (SR) (0.2-mm X 10-bit pixel matrix) were compared in the evaluation of 40 mediastinal and 30 pulmonary lesions in 60 patients who underwent computed tomography of the chest. The six SR algorithms varied among each other in only one image parameter. One algorithm approximated conventional image characteristics. The other five algorithms were designed to optimize imaging of the mediastinum and tested the effects of gray-scale reversal, adjustment of optical density, a linear instead of a sigmoid gradation curve, and moderate edge enhancement of high and medium spatial frequencies. Performance was evaluated by calculating the average area under the receiver operating characteristic curve (Az) of 5,040 observations by six readers. Post-processing with high-frequency edge enhancement and density optimization for the mediastinum significantly improved performance of SR over FR in the detection of mediastinal lesions (Az = .80 +/- .02 vs .73 +/- .01, respectively). Gray-scale reversal significantly decreased performance (Az = .64 +/- .03). All SR algorithms that were postprocessed to optimize imaging of the mediastinum were significantly inferior to FR in the detection of pulmonary lesions.