Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Correction (v179,p881)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suleiman, O.
Right arrow Articles by Rosenstein, M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suleiman, O.
Right arrow Articles by Rosenstein, M

Radiology, Vol 178, 653-658, Copyright © 1991 by Radiological Society of North America


ARTICLES

Tissue doses in the upper gastrointestinal fluoroscopy examination [published erratum appears in Radiology 1991 Jun;179(3):881]

OH Suleiman, J Anderson, B Jones, GU Rao and M Rosenstein
Office of Training and Assistance, Food and Drug Administration, Rockville, Md. 20857.

A method was developed to estimate tissue doses from the upper gastrointestinal fluoroscopy examination. It involved measuring the technical parameters of the clinical examination, partitioning the dynamic examination into a set of discrete x-ray fields, and generating corresponding tissue does tables with an existing computer program. Knowledge of the radiation exposures associated with each of the fields enabled the calculation of tissue doses for the entire dynamic examination. In this limited sample (eight patients), fluoroscopy times ranged from 108 to 183 seconds. Radiation exposures ranged from 2.3 to 7.2 mC/kg (9.1-28 R), thyroid doses from 0.15 to 3.5 mGy (15-350 mrad), uterine doses from 0.16 to 1.0 mGy (16-100 mrad), lung doses from 0.90 to 4.2 mGy (90-420 mrad), and active bone marrow doses from 0.81 to 5.4 mGy (81-540 mrad).


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
T. A. Jaffe, A. M. Gaca, S. Delaney, T. T. Yoshizumi, G. Toncheva, G. Nguyen, and D. P. Frush
Radiation Doses from Small-Bowel Follow-Through and Abdominopelvic MDCT in Crohn's Disease
Am. J. Roentgenol., November 1, 2007; 189(5): 1015 - 1022.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E Yakoumakis, I A Tsalafoutas, D Nikolaou, I Nazos, E Koulentianos, and C. Proukakis
Differences in effective dose estimation from dose-area product and entrance surface dose measurements in intravenous urography
Br. J. Radiol., August 1, 2001; 74(884): 727 - 734.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1991 by the Radiological Society of North America.