Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Herold, C.
Right arrow Articles by Zerhouni, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Herold, C.
Right arrow Articles by Zerhouni, E.

Radiology, Vol 178, 715-720, Copyright © 1991 by Radiological Society of North America


ARTICLES

Pulmonary atelectasis: signal patterns with MR imaging

CJ Herold, JE Kuhlman and EA Zerhouni
Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Medical Institutions, Baltimore, MD.

To assess the signal characteristics of different types of pulmonary atelectasis on magnetic resonance (MR) images, the authors studied obstructive atelectasis (OA) in 17 patients and nonobstructive atelectasis (NOA) in 25 patients. All patients underwent electrocardiographically gated MR imaging studies of the thorax with standard spin-echo sequences. No signal differences were observed between either type of atelectasis on T1-weighted images. Conversely, OA and NOA appeared significantly different on spin-density-weighted images (P less than .001) and on T2-weighted studies (P less than .0001). On T2-weighted images, all 17 cases of OA appeared hyperintense, whereas 22 of 25 cases of NOA demonstrated a very low signal intensity. Differences in the pathophysiology of OA and NOA presumably account for this observation. In OA, alveolar air is totally resorbed and secretions accumulate in the obstructed lung. The resulting increase in free fluid prolongs the T2 relaxation times and leads to high signal intensity on T2-weighted images. In NOA, the short T2 relaxation time of lung tissue in the absence of secretions and potential magnetic susceptibility effects due to residual air are likely to be responsible for the low T2 signal pattern.


This article has been cited by other articles:


Home page
RadiologyHome page
R. Eibel, P. Herzog, O. Dietrich, C. T. Rieger, H. Ostermann, M. F. Reiser, and S. O. Schoenberg
Pulmonary Abnormalities in Immunocompromised Patients: Comparative Detection with Parallel Acquisition MR Imaging and Thin-Section Helical CT
Radiology, December 1, 2006; 241(3): 880 - 891.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
N.L. Muller
Computed tomography and magnetic resonance imaging: past, present and future
Eur. Respir. J., February 1, 2002; 19(35_suppl): 3S - 12s.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. C. Leutner, J. Gieseke, G. Lutterbey, C. K. Kuhl, A. Glasmacher, E. Wardelmann, A. Theisen, and H. H. Schild
MR Imaging of Pneumonia in Immunocompromised Patients: Comparison with Helical CT
Am. J. Roentgenol., August 1, 2000; 175(2): 391 - 397.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1991 by the Radiological Society of North America.