|
|
||||||||
Radiology, Vol 178, 715-720, Copyright © 1991 by Radiological Society of North America
ARTICLES |
CJ Herold, JE Kuhlman and EA Zerhouni
Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Medical Institutions, Baltimore, MD.
To assess the signal characteristics of different types of pulmonary atelectasis on magnetic resonance (MR) images, the authors studied obstructive atelectasis (OA) in 17 patients and nonobstructive atelectasis (NOA) in 25 patients. All patients underwent electrocardiographically gated MR imaging studies of the thorax with standard spin-echo sequences. No signal differences were observed between either type of atelectasis on T1-weighted images. Conversely, OA and NOA appeared significantly different on spin-density-weighted images (P less than .001) and on T2-weighted studies (P less than .0001). On T2-weighted images, all 17 cases of OA appeared hyperintense, whereas 22 of 25 cases of NOA demonstrated a very low signal intensity. Differences in the pathophysiology of OA and NOA presumably account for this observation. In OA, alveolar air is totally resorbed and secretions accumulate in the obstructed lung. The resulting increase in free fluid prolongs the T2 relaxation times and leads to high signal intensity on T2-weighted images. In NOA, the short T2 relaxation time of lung tissue in the absence of secretions and potential magnetic susceptibility effects due to residual air are likely to be responsible for the low T2 signal pattern.
This article has been cited by other articles:
![]() |
R. Eibel, P. Herzog, O. Dietrich, C. T. Rieger, H. Ostermann, M. F. Reiser, and S. O. Schoenberg Pulmonary Abnormalities in Immunocompromised Patients: Comparative Detection with Parallel Acquisition MR Imaging and Thin-Section Helical CT Radiology, December 1, 2006; 241(3): 880 - 891. [Abstract] [Full Text] [PDF] |
||||
![]() |
N.L. Muller Computed tomography and magnetic resonance imaging: past, present and future Eur. Respir. J., February 1, 2002; 19(35_suppl): 3S - 12s. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. C. Leutner, J. Gieseke, G. Lutterbey, C. K. Kuhl, A. Glasmacher, E. Wardelmann, A. Theisen, and H. H. Schild MR Imaging of Pneumonia in Immunocompromised Patients: Comparison with Helical CT Am. J. Roentgenol., August 1, 2000; 175(2): 391 - 397. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |