Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Felmlee, J.
Right arrow Articles by Korin, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Felmlee, J.
Right arrow Articles by Korin, H.

Radiology, Vol 179, 139-142, Copyright © 1991 by Radiological Society of North America


ARTICLES

Adaptive motion compensation in MR imaging without use of navigator echoes

JP Felmlee, RL Ehman, SJ Riederer and HW Korin
MR Research Laboratory, Mayo Clinic and Foundation, Rochester, MN 55905.

Retrospective correction of magnetic resonance (MR) image data to eliminate the effects of patient motion is possible with use of adaptive correction techniques. These methods require an accurate record of the motion that occurs during imaging. The authors evaluated whether motion information suitable for adaptive correction could be obtained from phase-encoded image data alone rather than from separate navigator echoes. Once such displacements were estimated from the image data, motion correction proceeded with use of the same algorithm used for the navigator echoes. The results show that image data alone can be used to effectively measure view-to-view displacements in phantoms, but external markers are required for accurate measurement during axial head imaging of patients.


This article has been cited by other articles:


Home page
RadiologyHome page
M. Stuber, R. M. Botnar, P. G. Danias, K. V. Kissinger, and W. J. Manning
Submillimeter Three-dimensional Coronary MR Angiography with Real-time Navigator Correction: Comparison of Navigator Locations
Radiology, August 1, 1999; 212(2): 579 - 587.