Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Karczmar, G.
Right arrow Articles by Weiner, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Karczmar, G.
Right arrow Articles by Weiner, M.

Radiology, Vol 179, 149-153, Copyright © 1991 by Radiological Society of North America


ARTICLES

P-31 spectroscopy study of response of superficial human tumors to therapy

GS Karczmar, DJ Meyerhoff, MD Boska, B Hubesch, J Poole, GB Matson, F Valone and MW Weiner
Magnetic Resonance Unit, Veterans Administration Medical Center, San Francisco.

Studies were performed to characterize phosphorus-31 magnetic resonance (MR) spectra obtained from 10 superficial human tumors outside the brain and to determine whether P-31 MR spectroscopy could allow detection of a response to therapy before a change in tumor size was measured. The ratio of phosphomonoester to adenosine triphosphate peak intensities (PME/ATP) was unusually large in all tumors studied. The average PME/ATP in lymphomas (1.8 +/- 0.5) was greater than in nonlymphoma cancers (1.1 +/- 0.15). The average PME/ATP for all tumors studied (1.4 +/- 0.5) was much greater than that of underlying skeletal muscle (0.23 +/- .09). Eight of the tumors were studied before and after therapy. Responders were distinguished from nonresponders on the basis of changes in tumor size. PME/ATP decreased during therapy in three lymphomas that responded to therapy. In an adenocarcinoma and Ewing sarcoma that did not respond to therapy, PME/ATP increased. PME/ATP remained constant in two squamous cell carcinomas that responded to therapy and decreased in one squamous cell carcinoma that decreased in size by 40% but was classified as a nonresponder. Changes in PME/ATP did not always parallel changes in tumor size during therapy. In two patients, a decrease in PME/ATP preceded a decrease in tumor size. In four patients, PME/ATP increased transiently during periods when tumor size remained constant.


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
E. Batista, H. J. Khoury, F. A. Melo, V. Barros, and E. F. da Silva Jr.
The performance of commercial photodiodes for dosimetry in mammography
Radiat Prot Dosimetry, December 20, 2005; 115(1-4): 391 - 393.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1991 by the Radiological Society of North America.