Radiology, Vol 181, 393-397, Copyright © 1991 by Radiological Society of North America
ARTICLES |
EC Wong, A Jesmanowicz and JS Hyde
Department of Radiology, Medical College of Wisconsin, Milwaukee 53226.
The many fibrous tissues of the wrist and hand have short T2s, and, because of the small size of the tissues, their magnetic resonance (MR) imaging necessitates use of the high spatial resolution obtainable with fields of view as small as 2 cm x 2 cm x 1 mm. The authors demonstrate that the use of a local xyz gradient coil, positioned off-center in a clinical MR imager to facilitate patient positioning, permits acquisition of high-resolution images in spin-echo (SE) and gradient- recalled-echo (GRE) sequences with echo time (TE) as short as 6 msec (SE) or 3 msec (GRE). The authors compare this method for obtaining high-resolution images with the alternative method of using normal gradient strengths and increased pulse duration. The effects on image quality of TE, bandwidth, gradient strength, and chemical shift artifacts are presented. Images obtained with the local gradient coil of the carpal tunnel, carpal bones, and proximal interphalangeal joint in healthy volunteers are shown.
This article has been cited by other articles:
![]() |
I. Eshed, M. Bollow, D. G McGonagle, A. L. Tan, C. E Althoff, P. Asbach, and K.-G. A Hermann MRI of enthesitis of the appendicular skeleton in spondyloarthritis Ann Rheum Dis, December 1, 2007; 66(12): 1553 - 1559. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Saupe, K. P. Prussmann, R. Luechinger, P. Bosiger, B. Marincek, and D. Weishaupt MR Imaging of the Wrist: Comparison between 1.5- and 3-T MR Imaging--Preliminary Experience Radiology, January 1, 2005; 234(1): 256 - 264. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kocharian, M. C. Adkins, K. K. Amrami, K. P. McGee, P. A. Rouleau, D. E. Wenger, R. L. Ehman, and J. P. Felmlee Wrist: Improved MR Imaging with Optimized Transmit-Receive Coil Design Radiology, June 1, 2002; 223(3): 870 - 876. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Muhle, L. R. Frank, T. Rand, L. Yeh, E. C. Wong, A. Skaf, R. W. M. Dantas, P. Haghighi, D. Trudell, and D. Resnick Collateral Ligaments of the Ankle: High-Resolution MR Imaging with a Local Gradient Coil and Anatomic Correlation in Cadavers RadioGraphics, May 1, 1999; 19(3): 673 - 683. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. R. Frank, E. C. Wong, W.-M. Luh, J. M. Ahn, and D. Resnick Articular Cartilage in the Knee: Mapping of the Physiologic Parameters at MR Imaging with a Local Gradient Coil—Preliminary Results Radiology, January 1, 1999; 210(1): 241 - 246. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |