Radiology, Vol 187, 439-443, Copyright © 1993 by Radiological Society of North America
ARTICLES |
K Rosenkranz, W Zendel, R Langer, T Heim, P Schubeus, A Scholz, R Schlief, R Schurmann and R Felix
Department of Radiology, Rudolf Virchow University Clinics, Freie Universitat Berlin, Germany.
The purpose of this first patient study (phase II) was to evaluate the clinical usefulness of a new echo contrast agent at transcranial Doppler ultrasonography (US). Twenty patients were selected from a group of 242 patients undergoing conventional transcranial Doppler US who had low (n = 18) or absent (n = 2) Doppler signals from the middle cerebral artery (MCA). The extent and duration of Doppler signal increase was measured in 30 MCAs and in 14 basilar arteries following the intravenous injection of a transpulmonary galactose microparticle suspension (SH U 508 A) at three concentrations (200, 300, and 400 mg/mL). Doppler waveform analysis became possible in 93% (28 of 30) of the MCAs following injection. The maximal increase in average Doppler signal intensity (11 dB at 200 mg/mL, 15 dB at 300 mg/mL, and 17 dB at 400 mg/mL) and the increase in average duration of the signal enhancement (163 seconds at 200 mg/mL, 219 seconds at 300 mg/mL, and 240 seconds at 400 mg/mL) depended on contrast agent concentration. Doppler waveform analysis became possible in 79% (11 of 14) of the basilar arteries. The intravenous injection of this new echo contrast agent markedly increases Doppler signal intensity in patients with nondiagnostic results at conventional Doppler US.
This article has been cited by other articles:
![]() |
M. Engelhardt, W. Folkers, C. Brenke, M. Scholz, A. Harders, H. Fidorra, and K. Schmieder Neurosurgical operations with the patient in sitting position: analysis of risk factors using transcranial Doppler sonography Br. J. Anaesth., April 1, 2006; 96(4): 467 - 472. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Gerriets, T. Postert, M. Goertler, E. Stolz, F. Schlachetzki, U. Sliwka, G. Seidel, S. Weber, and M. Kaps DIAS I: Duplex-Sonographic Assessment of the Cerebrovascular Status in Acute Stroke : A Useful Tool for Future Stroke Trials Stroke, October 1, 2000; 31(10): 2342 - 2345. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. G. Khan, P. Gailloud, R. O. Bude, J.-B. Martin, K. T. Szopinski, C. Khaw, D. A. Rüfenacht, and K. J. Murphy The Effect of Contrast Material on Transcranial Doppler Evaluation of Normal Middle Cerebral Artery Peak Systolic Velocity AJNR Am. J. Neuroradiol., February 1, 2000; 21(2): 386 - 390. [Abstract] [Full Text] |
||||
![]() |
T. Gerriets, G. Seidel, I. Fiss, B. Modrau, and M. Kaps Contrast-enhanced transcranial color-coded duplex sonography: Efficiency and validity Neurology, April 1, 1999; 52(6): 1133 - 1133. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Frauscher, G. Janetschek, G. Helweg, H. Strasser, G. Bartsch, and D. z. Nedden Crossing Vessels at the Ureteropelvic Junction: Detection with Contrast-enhanced Color Doppler Imaging Radiology, March 1, 1999; 210(3): 727 - 731. [Abstract] [Full Text] |
||||
![]() |
R. W. Baumgartner, M. Arnold, F. Gonner, I. Staikow, C. Herrmann, A. Rivoir, and R. M. Muri Contrast-Enhanced Transcranial Color-Coded Duplex Sonography in Ischemic Cerebrovascular Disease Stroke, December 1, 1997; 28(12): 2473 - 2478. [Abstract] [Full Text] |
||||
![]() |
G. Seidel and M. Kaps Harmonic Imaging of the Vertebrobasilar System Stroke, August 1, 1997; 28(8): 1610 - 1613. [Abstract] [Full Text] |
||||
![]() |
R. W. Baumgartner, C. Schmid, and I. Baumgartner Comparative Study of Power-Based Versus Mean Frequency-Based Transcranial Color-Coded Duplex Sonography in Normal Adults Stroke, January 1, 1996; 27(1): 101 - 104. [Abstract] [Full Text] |
||||