Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hopper, K. D.
Right arrow Articles by Shirk, S. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hopper, K. D.
Right arrow Articles by Shirk, S. J.

Radiology, Vol 187, 653-660, Copyright © 1993 by Radiological Society of North America


ARTICLES

Automated biopsy devices: a blinded evaluation

KD Hopper, CS Abendroth, KW Sturtz, YL Matthews, LA Stevens and SJ Shirk
Department of Radiology, Penn State University, Hershey 17033.

To evaluate 20 different automated biopsy devices with respect to the quality of tissue obtained for histopathologic analysis, a total of 1,470 18-gauge biopsy specimens were obtained from 10 fresh autopsy cases, including 30 liver, 20 kidney, 10 pancreas, and 10 psoas muscle biopsy specimens per device and per biopsy depth. There was no statistical difference in the performance of the long-throw Biopty, ASAP 18, 1.9-cm UltraCut, long-throw Monopty, and 2.5-cm ABS biopsy guns. All obtained a large amount of tissue with minimal fragmentation or crush artifact. Most of the short-throw biopsy guns (depth of biopsy < or = 1.1 cm) did not perform as well. Although the other guns performed adequately, less than optimal results were obtained with the Temno, Bio-Gun, Roth, Klear Kut, ABC, and Urocut biopsy guns. Most 18- gauge automated biopsy devices with a biopsy excursion of at least 2.0 cm provide a high-quality, diagnostically adequate specimen for histopathologic analysis.


This article has been cited by other articles:


Home page
Eur Respir JHome page
M. Hayot, A. Michaud, C. Koechlin, M-A. Caron, P. LeBlanc, C. Prefaut, and F. Maltais
Skeletal muscle microbiopsy: a validation study of a minimally invasive technique
Eur. Respir. J., March 1, 2005; 25(3): 431 - 440.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
T. Yamagami, S. Iida, T. Kato, O. Tanaka, S. Toda, D. Kato, and T. Nishimura
Usefulness of New Automated Cutting Needle for Tissue-Core Biopsy of Lung Nodules Under CT Fluoroscopic Guidance
Chest, July 1, 2003; 124(1): 147 - 154.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. D. Hopper, K. Singapuri, and A. Finkel
Body CT and Oncologic Imaging
Radiology, April 1, 2000; 215(1): 27 - 40.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1993 by the Radiological Society of North America.