|
|
||||||||
Radiology, Vol 188, 371-376, Copyright © 1993 by Radiological Society of North America
ARTICLES |
MC Dulce, GH Mostbeck, KK Friese, GR Caputo and CB Higgins
Department of Radiology, University of California, San Francisco 94143- 0628.
Acquisition and measurement of left ventricular (LV) volumes with a three-dimensional data set of cine magnetic resonance (MR) images from apex to base is a time-consuming process. Results of a study with 10 healthy volunteers and 10 patients with LV hypertrophy were prospectively evaluated. The heart was shown in the anatomic short- and horizontal long-axis planes with cine MR imaging. LV volumes were measured with various geometric models, and ejection fractions were calculated. In both groups, the values of LV stroke volume obtained with a modified Simpson rule and biplane ellipsoid models correlated well to the analysis of the three-dimensional data set of cine MR images. There were no significant differences for the calculated ejection fraction between values obtained with the modified Simpson rule or the biplane ellipsoid model versus the three-dimensional data set. A high inter-observer reproducibility of cine MR measurements with the two former models was found. Therefore, modified Simpson rule and biplane ellipsoid models, with their shorter acquisition and processing times, may increase the clinical utility of cine MR imaging.
This article has been cited by other articles:
![]() |
A. Ichinose, H. Otani, M. Oikawa, K. Takase, H. Saito, H. Shimokawa, and S. Takahashi MRI of Cardiac Sarcoidosis: Basal and Subepicardial Localization of Myocardial Lesions and Their Effect on Left Ventricular Function Am. J. Roentgenol., September 1, 2008; 191(3): 862 - 869. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Brodoefel, U. Kramer, A. Reimann, C. Burgstahler, S. Schroeder, A. Kopp, and M. Heuschmid Dual-Source CT with Improved Temporal Resolution in Assessment of Left Ventricular Function: A Pilot Study Am. J. Roentgenol., November 1, 2007; 189(5): 1064 - 1070. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. M. Schaefer, C. S.A. Lipke, D. Standke, H. P. Kuhl, B. Nowak, H.-J. Kaiser, K.-C. Koch, and U. Buell Quantification of Left Ventricular Volumes and Ejection Fraction from Gated 99mTc-MIBI SPECT: MRI Validation and Comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT J. Nucl. Med., August 1, 2005; 46(8): 1256 - 1263. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Lembcke, A. C. Borges, S. Dushe, P. M. Dohmen, T. H. Wiese, P. Rogalla, K.-G. A. Hermann, B. Hamm, and C. N. H. Enzweiler Assessment of Mitral Valve Regurgitation at Electron-Beam CT: Comparison with Doppler Echocardiography Radiology, July 1, 2005; 236(1): 47 - 55. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. X. Qin, T. Shiota, H. Tsujino, G. Saracino, R. D. White, N. L. Greenberg, J. Kwan, Z. B. Popovic, D. A. Agler, W. J. Stewart, et al. Mitral annular motion as a surrogate for left ventricular ejection fraction: real-time three-dimensional echocardiography and magnetic resonance imaging studies Eur J Echocardiogr, December 1, 2004; 5(6): 407 - 415. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. M. Schaefer, C. S.A. Lipke, B. Nowak, H.-J. Kaiser, P. Reinartz, A. Buecker, G. A. Krombach, U. Buell, and H. P. Kuhl Validation of QGS and 4D-MSPECT for Quantification of Left Ventricular Volumes and Ejection Fraction from Gated 18F-FDG PET: Comparison with Cardiac MRI J. Nucl. Med., January 1, 2004; 45(1): 74 - 79. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Wiesmann, A. Frydrychowicz, J. Rautenberg, R. Illinger, E. Rommel, A. Haase, and S. Neubauer Analysis of right ventricular function in healthy mice and a murine model of heart failure by in vivo MRI Am J Physiol Heart Circ Physiol, September 1, 2002; 283(3): H1065 - H1071. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Wiesmann, J. Ruff, S. Engelhardt, L. Hein, C. Dienesch, A. Leupold, R. Illinger, A. Frydrychowicz, K.-H. Hiller, E. Rommel, et al. Dobutamine-Stress Magnetic Resonance Microimaging in Mice : Acute Changes of Cardiac Geometry and Function in Normal and Failing Murine Hearts Circ. Res., March 30, 2001; 88(6): 563 - 569. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. P. Chacko, F. Aresta, S. M. Chacko, and R. G. Weiss MRI/MRS assessment of in vivo murine cardiac metabolism, morphology, and function at physiological heart rates Am J Physiol Heart Circ Physiol, November 1, 2000; 279(5): H2218 - H2224. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. X. Qin, M. Jones, T. Shiota, N. L. Greenberg, H. Tsujino, M. S. Firstenberg, P. C. Gupta, A. D. Zetts, Y. Xu, J. P. Sun, et al. Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: in vitro and in vivo studies J. Am. Coll. Cardiol., September 1, 2000; 36(3): 900 - 907. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. L. Chuang, M. G. Hibberd, C. J. Salton, R. A. Beaudin, M. F. Riley, R. A. Parker, P. S. Douglas, and W. J. Manning Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction: Assessment by two- and three-dimensional echocardiography and magnetic resonance imaging J. Am. Coll. Cardiol., February 1, 2000; 35(2): 477 - 484. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Cottin, C. Touzery, F. Guy, A. Lalande, O. Ressencourt, S. Roy, P. M. Walker, P. Louis, F. Brunotte, and J. E. Wolf MR Imaging of the Heart in Patients after Myocardial Infarction: Effect of Increasing Intersection Gap on Measurements of Left Ventricular Volume, Ejection Fraction, and Wall Thickness Radiology, November 1, 1999; 213(2): 513 - 520. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |