Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tigges, S.
Right arrow Articles by Roberson, J. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tigges, S.
Right arrow Articles by Roberson, J. R.

Radiology, Vol 189, 485-488, Copyright © 1993 by Radiological Society of North America


ARTICLES

Hip aspiration: a cost-effective and accurate method of evaluating the potentially infected hip prosthesis

S Tigges, RG Stiles, RJ Meli and JR Roberson
Department of Radiology, Emory University School of Medicine, Atlanta, GA 30322.

PURPOSE: The accuracy of fluoroscopy-guided hip aspiration in the diagnosis of infection in hip prostheses was evaluated. MATERIALS AND METHODS: Results from 147 preoperative aspiration cultures were compared with results of operative cultures. The relative costs of aspiration and nuclear medicine studies were also compared. RESULTS: With the operative culture results as the standard, sensitivity of hip aspiration was 92.8% and specificity was 91.7%. The negative and positive predictive values were 99.2% and 54.2%, respectively. Aspiration arthrography costs approximately 20% as much as complementary technetium sulfur colloid-indium-111 granulocyte scans, the most accurate nuclear medicine study used to evaluate potentially infected hip prostheses. CONCLUSION: Hip aspiration is an accurate and cost-effective method of evaluating the potentially infected hip prosthesis.


This article has been cited by other articles:


Home page
RadiologyHome page
C. Cyteval, V. Hamm, M. P. Sarrabere, F. M. Lopez, P. Maury, and P. Taourel
Painful Infection at the Site of Hip Prosthesis: CT Imaging
Radiology, August 1, 2002; 224(2): 477 - 483.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. J. SPANGEHL, B. A. MASRI, J. X. O'CONNELL, and C. P. DUNCAN
Prospective Analysis of Preoperative and Intraoperative Investigations for the Diagnosis of Infection at the Sites of Two Hundred and Two Revision Total Hip Arthroplasties
J. Bone Joint Surg. Am., May 1, 1999; 81(5): 672 - 83.
[Abstract] [Full Text]


Home page
JBJSHome page
M. J. SPANGEHL, A. S. E. YOUNGER, B. A. MASRI, and C. P. DUNCAN
Instructional Course Lectures, The American Academy of Orthopaedic Surgeons - Diagnosis of Infection following Total Hip Arthroplasty*{{dagger}}
J. Bone Joint Surg. Am., October 1, 1997; 79(10): 1578 - 88.
[Full Text]


Home page
JBJSHome page
P. F. LACHIEWICZ, G. D. ROGERS, and H. C. THOMASON
Aspiration of the Hip Joint before Revision Total Hip Arthroplasty. Clinical and Laboratory Factors Influencing Attainment of a Positive Culture
J. Bone Joint Surg. Am., May 1, 1996; 78(5): 749 - 54.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1993 by the Radiological Society of North America.