|
|
||||||||
Radiology, Vol 190, 223-225, Copyright © 1994 by Radiological Society of North America
ARTICLES |
L Liberman, WP Evans 3rd, DD Dershaw, LE Hann, BM Deutch, AF Abramson and PP Rosen
Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY 10021.
PURPOSE: To describe the technique of specimen radiography in stereotaxically guided core biopsies and evaluate its role in detection and diagnosis of microcalcifications in breast tissue. MATERIALS AND METHODS: Specimens from 361 stereotaxic breast core biopsies of 72 nonpalpable lesions with mammographic evidence of microcalcifications were obtained from 65 patients. Specimens were placed in saline on microscope slides and radiographed. RESULTS: Microcalcifications were detected radiographically in 146 of 361 (40%) cores. If calcifications were present on specimen radiographs, histologic detection of these calcifications was made in 114 of 146 (78%) specimens, and diagnosis was made in 118 of 146 (81%). If calcifications were not present on specimen radiographs, histologic detection was obtained in 27 of 215 (13%) specimens and specific diagnosis in 81 of 215 (38%). CONCLUSION: Specimen radiography should be routinely performed in stereotaxic core biopsies of breast microcalcifications to ensure appropriate tissue has been obtained and to direct pathologic diagnosis of the tissue specimens.
This article has been cited by other articles:
![]() |
J.-M. Lee, J. B. Kaplan, M. P. Murray, L. Bartella, E. A. Morris, S. Joo, D. D. Dershaw, and L. Liberman Imaging Histologic Discordance at MRI-Guided 9-Gauge Vacuum-Assisted Breast Biopsy Am. J. Roentgenol., October 1, 2007; 189(4): 852 - 859. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Jackman and J. Rodriguez-Soto Breast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy--frequency, causes, and outcome. Radiology, April 1, 2006; 239(1): 61 - 70. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. R. Margolin, L. Kaufman, R. P. Jacobs, S. R. Denny, and J. D. Schrumpf Stereotactic Core Breast Biopsy of Malignant Calcifications: Diagnostic Yield of Cores with and Cores without Calcifications on Specimen Radiographs Radiology, October 1, 2004; 233(1): 251 - 254. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy Radiology, September 1, 2004; 232(3): 897 - 903. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Shousha Issues in the Interpretation of Breast Core Biopsies International Journal of Surgical Pathology, July 1, 2003; 11(3): 167 - 176. [Abstract] [PDF] |
||||
![]() |
P. D. Friedman, L. M. Sanders, C. Menendez, L. Kalisher, and G. Petrillo Retrieval of Lost Microcalcifications During Stereotactic Vacuum-Assisted Core Biopsy Am. J. Roentgenol., January 1, 2003; 180(1): 275 - 280. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Pfarl, T. H. Helbich, C. C. Riedl, T. Wagner, M. Gnant, M. Rudas, and L. Liberman Stereotactic 11-Gauge Vacuum-Assisted Breast Biopsy: A Validation Study Am. J. Roentgenol., December 1, 2002; 179(6): 1503 - 1507. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, J. B. Kaplan, E. A. Morris, A. F. Abramson, J. H. Menell, and D. D. Dershaw To Excise or To Sample the Mammographic Target: What Is the Goal of Stereotactic II-Gauge Vacuum-Assisted Breast Biopsy? Am. J. Roentgenol., September 1, 2002; 179(3): 679 - 683. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Wunderbaldinger, G. Wolf, K. Turetschek, and T. H. Helbich Comparison of Sitting Versus Prone Position for Stereotactic Large-Core Breast Biopsy in Surgically Proven Lesions Am. J. Roentgenol., May 1, 2002; 178(5): 1221 - 1225. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Becker, D. Taves, L. McCurdy, G. Muscedere, S. Karlik, and S. Ward Stereotactic Core Biopsy of Breast Microcalcifications: Comparison of Film Versus Digital Mammography, Both Using an Add-On Unit Am. J. Roentgenol., December 1, 2001; 177(6): 1451 - 1457. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, C. A. Gougoutas, M. F. Zakowski, L. R. LaTrenta, A. F. Abramson, E. A. Morris, and D. D. Dershaw Calcifications Highly Suggestive of Malignancy: Comparison of Breast Biopsy Methods Am. J. Roentgenol., July 1, 2001; 177(1): 165 - 172. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, C. L. Benton, D. D. Dershaw, A. F. Abramson, L. R. LaTrenta, and E. A. Morris Learning Curve for Stereotactic Breast Biopsy: How Many Cases Are Enough? Am. J. Roentgenol., March 1, 2001; 176(3): 721 - 727. [Abstract] [Full Text] [PDF] |
||||
![]() |
N J Coombs, J R L Laddie, G T Royle, C M Rubin, and M S Briley Improving the sensitivity of stereotactic core biopsy to diagnose ductal carcinoma in situ of the breast: a mathematical model Br. J. Radiol., February 1, 2001; 74(878): 123 - 126. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199. [Full Text] [PDF] |
||||
![]() |
H. E. Reynolds Core Needle Biopsy of Challenging Benign Breast Conditions: A Comprehensive Literature Review Am. J. Roentgenol., May 1, 2000; 174(5): 1245 - 1250. [Full Text] [PDF] |
||||
![]() |
J. M. Johnson, R. R. Dalton, S. M. Wester, J. Landercasper, and P. J. Lambert Histological Correlation of Microcalcifications in Breast Biopsy Specimens Arch Surg, July 1, 1999; 134(7): 712 - 716. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |