Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Swan, J. S.
Right arrow Articles by Wojtowycz, M. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Swan, J. S.
Right arrow Articles by Wojtowycz, M. M.

Radiology, Vol 190, 363-369, Copyright © 1994 by Radiological Society of North America


ARTICLES

MR angiography of the pelvis with variable velocity encoding and a phased-array coil

JS Swan, TM Grist, DM Weber, IA Sproat and MM Wojtowycz
Department of Radiology, University of Wisconsin Clinical Science Center, Madison 53792.

PURPOSE: To evaluate the feasibility of an automated variable velocity- encoding sequence and improve the signal-to-noise ratio (S/N) on magnetic resonance angiograms with use of phase contrast and a pelvic phased-array coil. MATERIALS AND METHODS: Three cardiac-gated, two- dimensional (2D), phase-contrast (PC) sequences were evaluated in 10 healthy subjects. A 2D gated PC sequence with variable velocity encoding (velocity-optimized phase contrast [VOPC]) was compared with gated 2D PC sequences performed with high or low constant velocity encoding. S/Ns in VOPC images obtained with a pelvic phased-array coil were compared with those in VOPC images obtained with a body coil. RESULTS: Two blinded readers preferred VOPC for simultaneous display of large and small blood vessels in one acquisition compared with constant low (P = .0105) and high (P = .0067) velocity encoding and for overall image interpretation. VOPC images obtained with the pelvic coil had a 68%-100% better S/N compared with those obtained with the body coil. CONCLUSION: Use of a phased-array coil and variable velocity encoding improves depiction of segmental vascular anatomic structures of the pelvis.


This article has been cited by other articles:


Home page
RadiologyHome page
D. P. Lum, K. M. Johnson, R. K. Paul, A. S. Turk, D. W. Consigny, J. R. Grinde, C. A. Mistretta, and T. M. Grist
Transstenotic Pressure Gradients: Measurement in Swine Retrospectively ECG-gated 3D Phase-Contrast MR Angiography versus Endovascular Pressure-sensing Guidewires
Radiology, December 1, 2007; 245(3): 751 - 760.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Ringgaard, S. A. Oyre, and E. M. Pedersen
Arterial MR Imaging Phase-Contrast Flow Measurement: Improvements with Varying Velocity Sensitivity during Cardiac Cycle
Radiology, July 1, 2004; 232(1): 289 - 294.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. M. Rofsky and M. A. Adelman
MR Angiography in the Evaluation of Atherosclerotic Peripheral Vascular Disease
Radiology, February 1, 2000; 214(2): 325 - 338.
[Abstract] [Full Text]


Home page
RadioGraphicsHome page
Y. Watanabe, M. Dohke, A. Okumura, Y. Amoh, T. Ishimori, K. Oda, T. Hayashi, A. Hiyama, and Y. Dodo
Dynamic Subtraction Contrast-enhanced MR Angiography: Technique, Clinical Applications, and Pitfalls
RadioGraphics, January 1, 2000; 20(1): 135 - 152.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.