Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Foo, T. K.
Right arrow Articles by Mills, D. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Foo, T. K.
Right arrow Articles by Mills, D. G.

Radiology, Vol 191, 85-90, Copyright © 1994 by Radiological Society of North America


ARTICLES

Inversion in the steady state: contrast optimization and reduced imaging time with fast three-dimensional inversion-recovery-prepared GRE pulse sequences

TK Foo, AM Sawyer, WH Faulkner and DG Mills
Applied Science Laboratory, GE Medical Systems, Milwaukee, WI 53201.

PURPOSE: To evaluate the differences in contrast between 1-second delay and zero delay (for magnetization recovery) before the preparation radio-frequency pulse in three-dimensional, inversion-recovery (IR) fast gradient-echo (GRE) acquisitions. MATERIALS AND METHODS: Mathematical simulations and measurements of brain image contrast were performed with healthy volunteers and 10 patients. RESULTS: The zero- delay sequence generated T1-weighted contrast similar to that obtained with 1-second delay but was accompanied by a substantial reduction in imaging time. However, the zero delay prohibits full recovery of the longitudinal magnetization. Hence, the signal null characteristic of IR experiments is not easily observed, since it occurs (as a function of tissue T1) at very short inversion times (< 150 msec). CONCLUSION: T1- weighted contrast comparable with that of magnetization-prepared rapid GRE sequences with a 1-second delay and preparation time (TP) of 600- 700 msec can be achieved in less time by using a zero delay and a shorter TP (400-500 msec).


This article has been cited by other articles:


Home page
RadiologyHome page
T. K. F. Foo, V. B. Ho, M. Saranathan, L.-q. Cheng, H. Sakuma, D. L. Kraitchman, K. C. Wu, and D. A. Bluemke
Feasibility of Integrating High-Spatial-Resolution 3D Breath-hold Coronary MR Angiography with Myocardial Perfusion and Viability Examinations
Radiology, June 1, 2005; 235(3): 1025 - 1030.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. C. Partridge, J. E. Gibbs, Y. Lu, L. J. Esserman, D. Sudilovsky, and N. M. Hylton
Accuracy of MR Imaging for Revealing Residual Breast Cancer in Patients Who Have Undergone Neoadjuvant Chemotherapy
Am. J. Roentgenol., November 1, 2002; 179(5): 1193 - 1199.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Orel and M. D. Schnall
MR Imaging of the Breast for the Detection, Diagnosis, and Staging of Breast Cancer
Radiology, July 1, 2001; 220(1): 13 - 30.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.