Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kegelmeyer, W. P.
Right arrow Articles by Nipper, M. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kegelmeyer, W. P., Jr
Right arrow Articles by Nipper, M. L.

Radiology, Vol 191, 331-337, Copyright © 1994 by Radiological Society of North America


ARTICLES

Computer-aided mammographic screening for spiculated lesions

WP Kegelmeyer Jr, JM Pruneda, PD Bourland, A Hillis, MW Riggs and ML Nipper
Sandia National Laboratories, Livermore, Calif.

PURPOSE: To study the use of a computer vision method as a second reader for the detection of spiculated lesions on screening mammograms. MATERIALS AND METHODS: An algorithmic computer process for the detection of spiculated lesions on digitized screen-film mammograms was applied to 85 four-view clinical cases: 36 cases with cancer proved by means of biopsy and 49 cases with negative findings at examination and follow-up. The computer detections were printed as film with added outlines that indicated the suspected cancers. Four radiologists screened the 85 cases twice, once without and once with the computer reports as ancillary films. RESULTS: The algorithm alone achieved 100% sensitivity, with a specificity of 82%. The computer reports increased the average radiologist sensitivity by 9.7% (P = .005), moving from 80.6% to 90.3%, with no decrease in average specificity. CONCLUSION: The study demonstrated that computer analysis of mammograms can provide a substantial and statistically significant increase in radiologist screening efficacy.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
T. E. Cupples, J. E. Cunningham, and J. C. Reynolds
Impact of Computer-Aided Detection in a Regional Screening Mammography Program
Am. J. Roentgenol., October 1, 2005; 185(4): 944 - 950.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
K Doi
Current status and future potential of computer-aided diagnosis in medical imaging
Br. J. Radiol., January 1, 2005; 78(suppl_1): S3 - s19.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. V. Destounis, P. DiNitto, W. Logan-Young, E. Bonaccio, M. L. Zuley, and K. M. Willison
Can Computer-aided Detection with Double Reading of Screening Mammograms Help Decrease the False-Negative Rate? Initial Experience
Radiology, August 1, 2004; 232(2): 578 - 584.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. A. Baker, E. L. Rosen, J. Y. Lo, E. I. Gimenez, R. Walsh, and M. S. Soo
Computer-Aided Detection (CAD) in Screening Mammography: Sensitivity of Commercial CAD Systems for Detecting Architectural Distortion
Am. J. Roentgenol., October 1, 2003; 181(4): 1083 - 1088.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. G. A. Gilhuijs, E. E. Deurloo, S. H. Muller, J. L. Peterse, and L. J. Schultze Kool
Breast MR Imaging in Women at Increased Lifetime Risk of Breast Cancer: Clinical System for Computerized Assessment of Breast Lesions—Initial Results
Radiology, December 1, 2002; 225(3): 907 - 916.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. W. Freer and M. J. Ulissey
Screening Mammography with Computer-aided Detection: Prospective Study of 12,860 Patients in a Community Breast Center
Radiology, September 1, 2001; 220(3): 781 - 786.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Jiang, R. M. Nishikawa, R. A. Schmidt, A. Y. Toledano, and K. Doi
Potential of Computer-aided Diagnosis to Reduce Variability in Radiologists' Interpretations of Mammograms Depicting Microcalcifications
Radiology, September 1, 2001; 220(3): 787 - 794.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. L. Birdwell, D. M. Ikeda, K. F. O’Shaughnessy, and E. A. Sickles
Mammographic Characteristics of 115 Missed Cancers Later Detected with Screening Mammography and the Potential Utility of Computer-aided Detection
Radiology, April 1, 2001; 219(1): 192 - 202.
[Abstract] [Full Text]


Home page
RadiologyHome page
C. J. Vyborny, T. Doi, K. F. O'Shaughnessy, H. M. Romsdahl, A. C. Schneider, and A. A. Stein
Breast Cancer: Importance of Spiculation in Computer-aided Detection
Radiology, June 1, 2000; 215(3): 703 - 707.
[Abstract] [Full Text]


Home page
RadiologyHome page
H.-P. Chan, B. Sahiner, M. A. Helvie, N. Petrick, M. A. Roubidoux, T. E. Wilson, D. D. Adler, C. Paramagul, J. S. Newman, and S. Sanjay-Gopal
Improvement of Radiologists' Characterization of Mammographic Masses by Using Computer-aided Diagnosis: An ROC Study
Radiology, September 1, 1999; 212(3): 817 - 827.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.