Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Trerotola, S. O.
Right arrow Articles by Osterman, F. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Trerotola, S. O.
Right arrow Articles by Osterman, F. A., Jr

Radiology, Vol 191, 721-726, Copyright © 1994 by Radiological Society of North America


ARTICLES

Thrombosed dialysis access grafts: percutaneous mechanical declotting without urokinase

SO Trerotola, GB Lund, PJ Scheel Jr, SJ Savader, AC Venbrux and FA Osterman Jr
Department of Radiology, University Hospital, Indiana University Medical Center, Indianapolis 46202-5253.

PURPOSE: To evaluate percutaneous declotting of dialysis access grafts with available catheters without urokinase. MATERIALS AND METHODS: Thirty-four clotted grafts were treated in 24 patients. Clot was macerated and pushed into the central circulation with balloon catheters. RESULTS: Successful mechanical declotting was performed in all but two patients (94%). The procedure was abandoned after successful declotting in four patients with poor venous outflow, resulting in a 24-hour success rate of 82%. Mean total procedure time was 116 minutes. Eight grafts clotted within 1 week. Using successful dialysis beyond 1 week as the measure of clinical success, the authors report a 59% clinical success rate with mean primary patency of 126 days (range, 16-322 days). Two complications, both emboli to the brachial artery, were successfully treated with urokinase. No symptomatic pulmonary emboli occurred. CONCLUSION: Mechanical thrombolysis of clotted grafts with currently available catheters yields results similar to those reported with mechanical devices and urokinase. The procedure is relatively inexpensive, safe, and well tolerated.


This article has been cited by other articles:


Home page
CJASNHome page
M. Allon
Current Management of Vascular Access
Clin. J. Am. Soc. Nephrol., July 1, 2007; 2(4): 786 - 800.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. M. Peirce, B. Funaki, T. G. Van Ha, and J. M. Lorenz
Percutaneous Declotting of Virgin Femoral Hemodialysis Grafts
Am. J. Roentgenol., December 1, 2005; 185(6): 1615 - 1619.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
L. Turmel-Rodrigues
Stenosis and thrombosis in haemodialysis fistulae and grafts: the radiologist's point of view
Nephrol. Dial. Transplant., February 1, 2004; 19(2): 306 - 308.
[Full Text] [PDF]


Home page
RadiologyHome page
H.-L. Liang, H.-B. Pan, H.-M. Chung, L.-P. Ger, H.-C. Fang, T.-H. Wu, M.-T. Wu, P.-H. Lai, C. K-H Chen, and C.-F. Yang
Restoration of Thrombosed Brescia-Cimino Dialysis Fistulas by Using Percutaneous Transluminal Angioplasty
Radiology, March 21, 2002; (2002) 2232010821.
[Abstract] [Full Text]


Home page
Nephrol Dial TransplantHome page
H. F. M. Smits, J. H. M. Smits, A. F. J. Wust, E. Buskens, and P. J. Blankestijn
Percutaneous thrombolysis of thrombosed haemodialysis access grafts: comparison of three mechanical devices
Nephrol. Dial. Transplant., March 1, 2002; 17(3): 467 - 473.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. P. Murray, T. B. Kinney, K. Valji, A. C. Roberts, S. C. Rose, and S. B. Oglevie
Early Rethrombosis of Clotted Hemodialysis Grafts: Graft Salvage Achieved with an Aggressive Approach
Am. J. Roentgenol., August 1, 2000; 175(2): 529 - 532.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. P. Smith
Pulmonary Embolism: What's Wrong with This Diagnosis?
Am. J. Roentgenol., June 1, 2000; 174(6): 1489 - 1497.
[Full Text]


Home page
RadiologyHome page
C. T. Sofocleous, S. G. Cooper, I. Schur, R. I. Patel, A. Iqbal, and S. Walker
Retrospective Comparison of the Amplatz Thrombectomy Device with Modified Pulse-Spray Pharmacomechanical Thrombolysis in the Treatment of Thrombosed Hemodialysis Access Grafts
Radiology, November 1, 1999; 213(2): 561 - 567.
[Abstract] [Full Text]


Home page
CLIN APPL THROMB HEMOSTHome page
J. J. Sands and C. L. Miranda
State-of-the-Art Review : Treatment of Hemodialysis Access Failure: A Role for Thrombolysis
Clinical and Applied Thrombosis/Hemostasis, July 1, 1996; 2(3): 164 - 168.
[Abstract] [PDF]


Home page
RadiologyHome page
H.-L. Liang, H.-B. Pan, H.-M. Chung, L.-P. Ger, H.-C. Fang, T.-H. Wu, M.-T. Wu, P.-H. Lai, C. K-H Chen, and C.-F. Yang
Restoration of Thrombosed Brescia-Cimino Dialysis Fistulas by Using Percutaneous Transluminal Angioplasty
Radiology, May 1, 2002; 223(2): 339 - 344.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.