|
|
||||||||
Radiology, Vol 192, 709-715, Copyright © 1994 by Radiological Society of North America
ARTICLES |
Y Anzai, KE Blackwell, SL Hirschowitz, JW Rogers, Y Sato, WT Yuh, VM Runge, MR Morris, SJ McLachlan and RB Lufkin
Department of Radiological Sciences, University of California, Los Angeles 90024-1721.
PURPOSE: To investigate the efficacy of magnetic resonance (MR) imaging with dextran-coated superparamagnetic iron oxide in the differentiation of metastatic and benign nodes in patients with head and neck cancer. MATERIALS AND METHODS: MR imaging was performed before and after intravenous administration of iron oxide in 12 patients. Ninety-one pathologically proved nodes were visually analyzed, and 66 lymph nodes were quantitatively analyzed by measuring signal intensity in visually selected regions of interest. RESULTS: Forty of 42 histologically proved metastatic nodes and 41 of 49 benign nodes were detected, yielding 95% sensitivity and 84% specificity. The signal intensity ratio of benign nodes was substantially lower than that of metastatic nodes, indicating better differentiation of metastatic and benign nodes. Furthermore, 13 of 14 normal-sized nodes were detected. CONCLUSION: MR imaging with iron oxide can enable specific differentiation of metastatic and benign nodes in patients with head and neck cancer. This agent may potentially enhance the detection of metastatic lymph nodes and deserves further investigation.
This article has been cited by other articles:
![]() |
D. J. A. Margolis, J. M. Hoffman, R. J. Herfkens, R. B. Jeffrey, A. Quon, and S. S. Gambhir Molecular Imaging Techniques in Body Imaging Radiology, November 1, 2007; 245(2): 333 - 356. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Saksena, M. Harisinghani, P. Hahn, J. Kim, A. Saokar, B. King, and R. Weissleder Comparison of lymphotropic nanoparticle-enhanced MRI sequences in patients with various primary cancers. Am. J. Roentgenol., December 1, 2006; 187(6): W582 - W588. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Choi, M. H. Han, W. K. Moon, K. R. Son, J.-K. Won, J.-H. Kim, B. J. Kwon, D. G. Na, H.-J. Weinmann, and K.-H. Chang Cervical Lymph Node Metastases: MR Imaging of Gadofluorine M and Monocrystalline Iron Oxide Nanoparticle-47 in a Rabbit Model of Head and Neck Cancer Radiology, December 1, 2006; 241(3): 753 - 762. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Memarsadeghi, C. C. Riedl, A. Kaneider, A. Galid, M. Rudas, W. Matzek, and T. H. Helbich Axillary Lymph Node Metastases in Patients with Breast Carcinomas: Assessment with Nonenhanced versus USPIO-enhanced MR Imaging. Radiology, November 1, 2006; 241(2): 367 - 377. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. M. L. L. G. Deserno, M. G. Harisinghani, M. Taupitz, G. J. Jager, J. A. Witjes, P. F. Mulders, C. A. Hulsbergen van de Kaa, D. Kaufmann, and J. O. Barentsz Urinary Bladder Cancer: Preoperative Nodal Staging with Ferumoxtran-10-enhanced MR Imaging Radiology, November 1, 2004; 233(2): 449 - 456. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Torabi, S. L. Aquino, and M. G. Harisinghani Current Concepts in Lymph Node Imaging J. Nucl. Med., September 1, 2004; 45(9): 1509 - 1518. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Misselwitz, J. Platzek, and H.-J. Weinmann Early MR Lymphography with Gadofluorine M in Rabbits Radiology, June 1, 2004; 231(3): 682 - 688. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Floris, E. L. A. Blezer, G. Schreibelt, E. Dopp, S. M. A. van der Pol, I. L. Schadee-Eestermans, K. Nicolay, C. D. Dijkstra, and H. E. de Vries Blood-brain barrier permeability and monocyte infiltration in experimental allergic encephalomyelitis: A quantitative MRI study Brain, March 1, 2004; 127(3): 616 - 627. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Anzai, C. W. Piccoli, E. K. Outwater, W. Stanford, D. A. Bluemke, P. Nurenberg, S. Saini, K. R. Maravilla, D. E. Feldman, U. P. Schmiedl, et al. Evaluation of Neck and Body Metastases to Nodes with Ferumoxtran 10-enhanced MR Imaging: Phase III Safety and Efficacy Study Radiology, September 1, 2003; 228(3): 777 - 788. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. G. Harisinghani, J. Barentsz, P. F. Hahn, W. M. Deserno, S. Tabatabaei, C. H. van de Kaa, J. de la Rosette, and R. Weissleder Noninvasive Detection of Clinically Occult Lymph-Node Metastases in Prostate Cancer N. Engl. J. Med., June 19, 2003; 348(25): 2491 - 2499. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. H. Kaim, T. Wischer, T. O'Reilly, G. Jundt, J. Frohlich, G. K. von Schulthess, and P. R. Allegrini MR Imaging with Ultrasmall Superparamagnetic Iron Oxide Particles in Experimental Soft-Tissue Infections in Rats Radiology, December 1, 2002; 225(3): 808 - 814. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. A. Michel, T. M. Keller, J. M. Frohlich, D. Fink, R. Caduff, B. Seifert, B. Marincek, and R. A. Kubik-Huch Preoperative Breast Cancer Staging: MR Imaging of the Axilla with Ultrasmall Superparamagnetic Iron Oxide Enhancement Radiology, November 1, 2002; 225(2): 527 - 536. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A Hudgins, Y. Anzai, M. R Morris, and M. A Lucas Ferumoxtran-10, A Superparamagnetic Iron Oxide as a Magnetic Resonance Enhancement Agent for Imaging Lymph Nodes: A Phase 2 Dose Study AJNR Am. J. Neuroradiol., April 1, 2002; 23(4): 649 - 656. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Schaefer-Prokop and M. Prokop New imaging techniques in the treatment guidelines for lung cancer Eur. Respir. J., February 1, 2002; 19(35_suppl): 71S - 83s. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Ruehm, T. Schroeder, and J. F. Debatin Interstitial MR Lymphography with Gadoterate Meglumine: Initial Experience in Humans Radiology, September 1, 2001; 220(3): 816 - 821. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kanno, Y.-J. L. Wu, P. C. Lee, S. J. Dodd, M. Williams, B. P. Griffith, and C. Ho Macrophage Accumulation Associated With Rat Cardiac Allograft Rejection Detected by Magnetic Resonance Imaging With Ultrasmall Superparamagnetic Iron Oxide Particles Circulation, August 21, 2001; 104(8): 934 - 938. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Ruehm, C. Corot, and J. F. Debatin Interstitial MR Lymphography with a Conventional Extracellular Gadolinium-based Agent: Assessment in Rabbits Radiology, March 1, 2001; 218(3): 664 - 669. [Abstract] [Full Text] |
||||
![]() |
S. Kanno, P. C. Lee, S. J. Dodd, M. Williams, B. P. Griffith, and C. Ho A novel approach with magnetic resonance imaging used for the detection of lung allograft rejection J. Thorac. Cardiovasc. Surg., November 1, 2000; 120(5): 923 - 934. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Dousset, L. Ballarino, C. Delalande, M. Coussemacq, P. Canioni, K. G. Petry, and J.-M. Caillé Comparison of Ultrasmall Particles of Iron Oxide (USPIO)-Enhanced T2-Weighted, Conventional T2-Weighted, and Gadolinium-Enhanced T1-Weighted MR Images in Rats with Experimental Autoimmune Encephalomyelitis AJNR Am. J. Neuroradiol., February 1, 1999; 20(2): 223 - 227. [Abstract] [Full Text] |
||||
![]() |
M. G. Mack, J. O. Balzer, R. Straub, K. Eichler, and T. J. Vogl Superparamagnetic Iron Oxide-enhanced MR Imaging of Head and Neck Lymph Nodes Radiology, January 1, 2002; 222(1): 239 - 244. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |