Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Little, A. F.
Right arrow Articles by Sammon, J. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Little, A. F.
Right arrow Articles by Sammon, J. K.

Radiology, Vol 193, 651-655, Copyright © 1994 by Radiological Society of North America


ARTICLES

Optimizing CT portography: a prospective comparison of injection into the splenic versus superior mesenteric artery

AF Little, RL Baron, MS Peterson, SR Confer, GD Dodd 3rd, TP Chambers, MP Federle, JH Oliver, PD Orons and JK Sammon
Department of Radiology, University of Pittsburgh Medical Center, PA 15213-2582.

PURPOSE: To evaluate whether computed tomographic arterial portography (CTAP) is best performed with injections in the superior mesenteric artery (SMA) or the splenic artery. MATERIALS AND METHODS: Seventy-one studies were performed with injection into the SMA (n = 37) or splenic artery (n = 34) of 150 mL of contrast material at 1.5 mL/sec and 20- second delay for both groups. Images were reviewed for location and type of nontumoral perfusion abnormalities. The degree of liver parenchymal enhancement with each technique was compared. RESULTS: Fewer nontumoral perfusion defects were seen with splenic artery (65%) versus SMA (78%) injection. Visual differences in contrast enhancement with greater attenuation in dependent portions of the liver were seen with greater frequency with SMA (41%) than with splenic artery (24%) injection. Contrast enhancement that obscured detail in the right lobe was seen only with SMA injections (16%). Greater parenchymal enhancement (up to 18 HU) at all time intervals was seen with splenic artery injection. CONCLUSION: Because of greater parenchymal enhancement and fewer nontumoral perfusion abnormalities, splenic artery catheterization is the preferred technique for CTAP.


This article has been cited by other articles:


Home page
JCOHome page
T. Akhurst, T. J. Kates, M. Mazumdar, H. Yeung, E. R. Riedel, B. M. Burt, L. Blumgart, W. Jarnagin, S. M. Larson, and Y. Fong
Recent Chemotherapy Reduces the Sensitivity of [18F]Fluorodeoxyglucose Positron Emission Tomography in the Detection of Colorectal Metastases
J. Clin. Oncol., December 1, 2005; 23(34): 8713 - 8716.
[Abstract] [Full Text] [PDF]


Home page
DiabetesHome page
S. D. Mittelman, G. W. Van Citters, E. L. Kirkman, and R. N. Bergman
Extreme Insulin Resistance of the Central Adipose Depot In Vivo
Diabetes, March 1, 2002; 51(3): 755 - 761.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Kondo, M. Kanematsu, H. Hoshi, T. Murakami, T. Kim, M. Hori, M. Matsuo, and H. Nakamura
Preoperative Detection of Malignant Hepatic Tumors: Comparison of Combined Methods of MR Imaging with Combined Methods of CT
Am. J. Roentgenol., April 1, 2000; 174(4): 947 - 954.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.