Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brink, J. A.
Right arrow Articles by Vannier, M. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brink, J. A.
Right arrow Articles by Vannier, M. W.

Radiology, Vol 194, 157-163, Copyright © 1995 by Radiological Society of North America


ARTICLES

Technical optimization of spiral CT for depiction of renal artery stenosis: in vitro analysis

JA Brink, JT Lim, G Wang, JP Heiken, LA Deyoe and MW Vannier
Department of Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO 63110.

PURPOSE: To determine empirically the effect of scan parameters and postprocessing techniques on depiction accuracy of renal artery stenosis with spiral computed tomographic angiography. MATERIALS AND METHODS: Critical (85%) and noncritical (45%) stenoses in the coronal plane were modeled in vitro and scanned with 12 combinations of collimation (1, 2, or 3 mm), table increment (pitch = 1-2),2 and reconstruction interval (0.5 or 1.0 mm). Five test images were generated for each spiral scanning technique: multiplanar reformation (MPR), maximum-intensity projections (MIPs: coronal MIP [MIPcor], coronal MIP targeted to phantom vessel and surrounding fat [target MIPcor]), transaxial imaging, and transaxial MIP. RESULTS: With 3-mm collimation, critical stenosis was overestimated to the point of occlusion on MIPcor images and underestimated on MPR and target MIPcor images. A 0.5-mm reconstruction interval was marginally beneficial for 1- and 2-mm collimation, but noise was prohibitive with 1-mm collimation. CONCLUSION: Critical renal artery stenosis is best depicted with 2-mm collimation, 2-4-mm table increment, and 1-mm reconstruction interval.