Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moshage, W. E.
Right arrow Articles by Kirchgeorg, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moshage, W. E.
Right arrow Articles by Kirchgeorg, M.

Radiology, Vol 196, 707-714, Copyright © 1995 by Radiological Society of North America


ARTICLES

Coronary artery stenoses: three-dimensional imaging with electrocardiographically triggered, contrast agent-enhanced, electron- beam CT

WE Moshage, S Achenbach, B Seese, K Bachmann and M Kirchgeorg
Department of Cardiology, University of Erlangen-Nurnberg, Germany.

PURPOSE: To compare electron-beam computed tomography (CT) and coronary angiography for depiction of coronary artery stenoses. MATERIALS AND METHODS: In 27 patients (age range, 50-70 years), electrocardiographically triggered axial electron-beam CT scans of the heart were obtained during breath hold and intravenous administration of contrast agent. Coronary arteries were reconstructed three- dimensionally. Electron-beam CT and angiographic results were compared. RESULTS: Significant enhancement within the vessel lumen (P < .001) permitted selective reconstruction of the inner coronary artery lumen. Nine of 11 high-grade stenoses and all five occlusions in the proximal left anterior descending artery and three of five high-grade right coronary artery stenoses were clearly identified. Recognition of stenosis of the left circumflex artery was not reliable. Success after percutaneous transfemoral coronary angioplasty was documented in five of five patients by visualizing the increase in vessel diameter at repeat investigation. CONCLUSION: Contrast-enhanced electron-beam CT yields promising results concerning the visualization of coronary artery stenoses.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.