Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Trerotola, S. O.
Right arrow Articles by Forney, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Trerotola, S. O.
Right arrow Articles by Forney, M.

Radiology, Vol 200, 169-176, Copyright © 1996 by Radiological Society of North America


ARTICLES

Pulmonary emboli from pulse-spray and mechanical thrombolysis: evaluation with an animal dialysis-graft model

SO Trerotola, MS Johnson, DS Schauwecker, DD Davidson, RS Filo, XH Zhou, GJ Eckert, RG Dreesen, KA Carlson and M Forney
Department of Radiology, University Hospital 0279, Indiana University Medical Center, Indianapolis 46202-5253, USA.

PURPOSE: To compare pulmonary emboli resulting from pulse-spray pharmacomechanical thrombolysis (PSPMT) and mechanical thrombolysis performed to declot dialysis-access grafts. MATERIALS AND METHODS: Polytetrafluoroethylene arteriovenous shunts were created in eight dogs and were deliberately clotted at monthly intervals. Animals were randomly assigned to treatment with pulse-spray urokinase thrombolysis or a low-speed rotational percutaneous thrombolytic device. Perfusion imaging, pulmonary-artery pressure measurements, and pulmonary arteriography were performed before and after each procedure. RESULTS: A total of 22 procedures were performed (11 PSPMT and 11 mechanical thrombolysis). Declotting was successful in all procedures, with 100% 30-day patency. Segmental defects were seen on perfusion images after 10 (91%) of 11 PSPMT procedures and two (18%) of 11 mechanical thrombolysis procedures (P < .002). Transient increases in pulmonary- artery pressure occurred in the PSPMT group. Complete resolution of emboli and return to baseline pressures were seen in all cases, even after multiple (up to four) procedures in the same animal. There was no histologic evidence of pulmonary infarction in either group. CONCLUSION: The percutaneous thrombolytic device is effective for declotting dialysis grafts in dogs and results in statistically significantly fewer pulmonary emboli compared with PSPMT.


This article has been cited by other articles:


Home page
RadiologyHome page
B. L. Dolmatch, F. Casteneda, T. O. McNamara, G. Zemel, M. Lieber, and A. H. Cragg
Synthetic Dialysis Shunts: Thrombolysis with the Cragg Thrombolytic Brush Catheter
Radiology, October 1, 1999; 213(1): 180 - 184.