Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hilfiker, P. R.
Right arrow Articles by Debatin, J. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hilfiker, P. R.
Right arrow Articles by Debatin, J. F.

Radiology, Vol 209, 769-774, Copyright © 1998 by Radiological Society of North America


ARTICLES

Intestinal and peritoneal bleeding: detection with an intravascular contrast agent and fast three-dimensional MR imaging--preliminary experience from an experimental study

PR Hilfiker, GG Zimmermann-Paul, M Schmidt, HP Klotz, GM Kacl and JF Debatin
Institute of Diagnostic Radiology, University Hospital Zurich, Switzerland.

PURPOSE: To assess the ability to detect and localize intestinal and peritoneal bleeding with an intravascular contrast agent and fast three- dimensional (3D) magnetic resonance (MR) imaging. MATERIALS AND METHODS: An intravascular contrast agent (NC100150 Injection) was administered into small-bowel specimens at five flow rates; the specimens were imaged with a 3D gradient-echo (GRE) sequence at 1- minute intervals. Radionuclide studies with technetium-99m pertechnetate were performed in the same manner. Subsequently, the MR imaging technique was assessed in vivo. Two intraluminal intestinal and one hepatic bleeding sites were created in an anesthetized pig. Three- dimensional GRE imaging data sets were acquired after intravenous injection of the contrast agent. Imaging findings were confirmed with macroscopic inspection. RESULTS: Contrast material injected at 0.5-2.0 mL/min was detected with both radionuclide and MR imaging after 1 minute. An accumulated volume of 0.2 mL was necessary to demonstrate the bleeding site. In vivo, all bleeding sites were readily detected on MR images. Contrast material accumulated in the intestines and peritoneal space. CONCLUSION: In conjunction with an intravascular contrast agent, 3D MR imaging allows detection and localization of gastrointestinal bleeding. The extent of the bleeding can be determined with repeat data acquisitions.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
H. Ersoy, P. Jacobs, C. K. Kent, and M. R. Prince
Blood Pool MR Angiography of Aortic Stent-Graft Endoleak
Am. J. Roentgenol., May 1, 2004; 182(5): 1181 - 1186.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Weishaupt, S. G. Ruhm, C. A. Binkert, M. Schmidt, M. A. Patak, F. Steybe, S. McGill, and J. F. Debatin
Equilibrium-Phase MR Angiography of the Aortoiliac and Renal Arteries Using a Blood Pool Contrast Agent
Am. J. Roentgenol., July 1, 2000; 175(1): 189 - 195.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1998 by the Radiological Society of North America.