Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maas, M.
Right arrow Articles by Akkerman, E. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maas, M.
Right arrow Articles by Akkerman, E. M.
(Radiology. 1999;210:189-193.)
© RSNA, 1999


Musculoskeletal Imaging

Uniform Fat Suppression in Hands and Feet through the Use of Two-Point Dixon Chemical Shift MR Imaging

Mario Maas, MD1, Piet F. Dijkstra, MD, PhD1 and Erik M. Akkerman, PhD1

1 Department of Diagnostic Radiology, Academic Medical Center, Meibergdreef 9/G1-231, 1105 AZ Amsterdam, the Netherlands.

PURPOSE: To assess the potential of two-point Dixon chemical shift magnetic resonance imaging to achieve uniform fat suppression in the distal parts of the extremities.

MATERIALS AND METHODS: Two-point Dixon chemical shift imaging was performed in 31 consecutive patients clinically suspected to have bone marrow disease. In some patients, Dixon studies were performed before and after the intravenous administration of gadopentetate dimeglumine, and in some patients follow-up examinations were performed, for a total of 64 studies. Areas of interest were the hand, wrist, foot, ankle, and lower leg. There was a special interest in the neuropathic foot and osteomyelitis. The uniformity of fat suppression in the entire field of view, the frequency of displacement artifacts, and the applicability of the technique in routine patient treatment were evaluated.

RESULTS: In 64 (100%) Dixon studies, uniform fat suppression was achieved. In 59 (92%) studies, there were no displacement artifacts. In five (8%) studies, displacement artifacts occurred; however, in only one (2%) study did they severely hamper the reading. Thus, in 63 (98%) studies, adequate diagnostic quality was obtained.

CONCLUSION: Two-point Dixon chemical shift imaging is a good technique for achieving uniform fat suppression in the distal parts of the extremities. Because the frequency of displacement artifacts is low, the technique is applicable in a routine clinical setting.

Index terms: Bone marrow, MR, 40.121414, 40.121415 • Bones, infection, 40.20 • Bones, neuropathic disorder, 40.821 • Diabetes mellitus, complications, 40.20 • Foot, MR, 46.21 • Hand, MR, 43.21 • Magnetic resonance (MR), chemical shift, 43.121414, 46.121414 • Magnetic resonance (MR), fat suppression, 43.121415, 46.121415




This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
R. A. W. Verhagen, M. Maas, M. G. W. Dijkgraaf, J. L. Tol, R. Krips, and C. N. van Dijk
Prospective study on diagnostic strategies in osteochondral lesions of the talus: IS MRI SUPERIOR TO HELICAL CT?
J Bone Joint Surg Br, January 1, 2005; 87-B(1): 41 - 46.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
S. A. Bus, M. Maas, P. R. Cavanagh, R. P. J. Michels, and M. Levi
Plantar Fat-Pad Displacement in Neuropathic Diabetic Patients With Toe Deformity: A magnetic resonance imaging study
Diabetes Care, October 1, 2004; 27(10): 2376 - 2381.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Maas, C. E. M. Hollak, E. M. Akkerman, J. M. F. G. Aerts, J. Stoker, and G. J. Den Heeten
Quantification of Skeletal Involvement in Adults with Type I Gaucher's Disease: Fat Fraction Measured by Dixon Quantitative Chemical Shift Imaging as a Valid Parameter
Am. J. Roentgenol., October 1, 2002; 179(4): 961 - 965.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. J. Rybicki, T. Chung, J. Reid, D. Jaramillo, R. V. Mulkern, and J. Ma
Fast Three-Point Dixon MR Imaging Using Low-Resolution Images for Phase Correction: A Comparison with Chemical Shift Selective Fat Suppression for Pediatric Musculoskeletal Imaging
Am. J. Roentgenol., November 1, 2001; 177(5): 1019 - 1023.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1999 by the Radiological Society of North America.