Technical Developments |
1 Department of Internal Medicine II, University of Erlangen-Nürnberg, Östliche Stadtmauerstrasse 29, 91054 Erlangen, Germany (W.K., S.A., D.R., W.M., W.G.D.)
2 Siemens Medical Engineering, Erlangen, Germany (G.L.).
Gadolinium-enhanced, three-dimensional, breath-hold magnetic resonance (MR) coronary angiography was performed in two healthy volunteers and 11 patients suspected or known to have coronary artery disease. MR angiograms were compared with those obtained with retrospective respiratory gating. Of 52 main coronary arteries, 47 could be visualized with the breath-hold technique and 49 with the gating technique. Signal-to-noise and contrast-to-noise ratios were significantly higher with the breath-hold technique. Overall image quality was slightly lower with breath-hold imaging. With either technique, three of five significant coronary stenoses were correctly identified.
Index terms: Coronary vessels, MR, 54.12142, 54.12143 Magnetic resonance (MR), vascular studies, 54.121416, 54.12142
This article has been cited by other articles:
![]() |
C. Jahnke, I. Paetsch, S. Achenbach, B. Schnackenburg, R. Gebker, E. Fleck, and E. Nagel Coronary MR Imaging: Breath-hold Capability and Patterns, Coronary Artery Rest Periods, and {beta}-Blocker Use Radiology, April 1, 2006; 239(1): 71 - 78. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. U. Herborn, M. Schmidt, O. Bruder, E. Nagel, K. Shamsi, and J. Barkhausen MR Coronary Angiography with SH L 643 A: Initial Experience in Patients with Coronary Artery Disease Radiology, November 1, 2004; 233(2): 567 - 573. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Jahnke, I. Paetsch, B. Schnackenburg, A. Bornstedt, R. Gebker, E. Fleck, and E. Nagel Coronary MR Angiography with Steady-State Free Precession: Individually Adapted Breath-hold Technique versus Free-breathing Technique Radiology, September 1, 2004; 232(3): 669 - 676. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Budoff, S. Achenbach, and A. Duerinckx Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiography J. Am. Coll. Cardiol., December 3, 2003; 42(11): 1867 - 1878. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. U. Herborn, J. Barkhausen, I. Paetsch, P. Hunold, M. Mahler, K. Shamsi, and E. Nagel Coronary Arteries: Contrast-enhanced MR Imaging with SH L 643A--Experience in 12 Volunteers Radiology, October 1, 2003; 229(1): 217 - 223. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Dirksen, H. J. Lamb, P. Kunz, P. Robert, C. Corot, and A. de Roos Improved MR Coronary Angiography with Use of a New Rapid Clearance Blood Pool Contrast Agent in Pigs Radiology, June 1, 2003; 227(3): 802 - 808. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Bogaert, R. Kuzo, S. Dymarkowski, R. Beckers, J. Piessens, and F. E. Rademakers Coronary Artery Imaging with Real-time Navigator Three-dimensional Turbo-Field-Echo MR Coronary Angiography: Initial Experience Radiology, March 1, 2003; 226(3): 707 - 716. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Li, J. C. Carr, S. M. Shea, J. Zheng, V. S. Deshpande, P. A. Wielopolski, and J. P. Finn Coronary Arteries: Magnetization-prepared Contrast-enhanced Three-dimensional Volume-targeted Breath-hold MR Angiography Radiology, April 1, 2001; 219(1): 270 - 277. [Abstract] [Full Text] |
||||
![]() |
D. Li, J. Zheng, and H.-J. Weinmann Contrast-enhanced MR Imaging of Coronary Arteries: Comparison of Intra- and Extravascular Contrast Agents in Swine Radiology, March 1, 2001; 218(3): 670 - 678. [Abstract] [Full Text] |
||||
![]() |
Y. Wang, R. Watts, I. R. Mitchell, T. D. Nguyen, J. W. Bezanson, G. W. Bergman, and M. R. Prince Coronary MR Angiography: Selection of Acquisition Window of Minimal Cardiac Motion with Electrocardiography-triggered Navigator Cardiac Motion Prescanning--Initial Results Radiology, February 1, 2001; 218(2): 580 - 585. [Abstract] [Full Text] |
||||
![]() |
W. Moshage, S. Achenbach, and W. G. Daniel Novel approaches to the non-invasive diagnosis of coronary-artery disease Nephrol. Dial. Transplant., January 1, 2001; 16(1): 21 - 28. [Full Text] [PDF] |
||||
![]() |
J.-M. Serfaty, E. Atalar, J. Declerck, P. Karmakar, H. H. Quick, K. A. Shunk, A. W. Heldman, and X. Yang Real-time Projection MR Angiography: Feasibility Study Radiology, October 1, 2000; 217(1): 290 - 295. [Abstract] [Full Text] |
||||
![]() |
M. Regenfus, D. Ropers, S. Achenbach, W. Kessler, G. Laub, W. G. Daniel, and W. Moshage Noninvasive detection of coronary artery stenosis using contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography J. Am. Coll. Cardiol., July 1, 2000; 36(1): 44 - 50. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Wang, P. A. Winchester, L. Yu, R. Watts, G. Ding, H. M. Lee, and G. W. Bergman Breath-Hold Three-dimensional Contrast-enhanced Coronary MR Angiography: Motion-matched k-Space Sampling for Reducing Cardiac Motion Effects Radiology, May 1, 2000; 215(2): 600 - 607. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |