Breast Imaging |
1 From the Department of Diagnostic Radiology, Yale University School of Medicine, 333 Cedar St, New Haven, CT 06520. From the 1997 RSNA scientific assembly. Received August 11, 1998; revision requested September 25; revision received November 10; accepted January 11, 1999. Address reprint requests to C.H.L.
PURPOSE: To determine how often lesions diagnosed as benign with stereotactic core-needle biopsy (SCNB) change at follow-up mammography and to determine the optimal follow-up strategy and the delayed false-negative rate.
MATERIALS AND METHODS: From July 1992 through December 1995, 355 of 540 cases (66%) in which SCNB yielded benign results were managed with follow-up mammography. Mammographic follow-up was available for 298 of these cases (84%). Follow-up mammography reports were reviewed. When a change was reported, pre- and postbiopsy mammograms, pathology reports, and results of subsequent mammographic follow-up were reviewed.
RESULTS: Mammographic change occurred in 21 of 298 cases (7%) at intervals of 655 months (mean, 20 months). Change occurred after initial mammographic stability in 10 of 21 cases. Repeat biopsy was performed in 18 of 21 cases. Malignancy was diagnosed in two cases: one mass that changed at 6 months and one case of microcalcifications that changed at 24 months. This represented a delayed false-negative rate of 2% (two of 105 malignancies among 540 biopsies).
CONCLUSION: A small percentage of cases diagnosed as benign with SCNB will change on follow-up mammograms, which may necessitate repeat biopsy. These results suggest that 6-month follow-up for cases that yield nonspecific benign results at SCNB and yearly screening mammography for cases with specific benign results is a reasonable management strategy.
Index terms: Breast, biopsy, 00.1267 Breast neoplasms, diagnosis, 00.1267 Breast radiography, utilization
This article has been cited by other articles:
![]() |
O. Graf, T. H. Helbich, G. Hopf, C. Graf, and E. A. Sickles Probably Benign Breast Masses at US: Is Follow-up an Acceptable Alternative to Biopsy? Radiology, July 1, 2007; 244(1): 87 - 93. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. Youk, E.-K. Kim, M. J. Kim, J. Y. Lee, and K. K. Oh Missed Breast Cancers at US-guided Core Needle Biopsy: How to Reduce Them RadioGraphics, January 1, 2007; 27(1): 79 - 94. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Jackman and J. Rodriguez-Soto Breast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy--frequency, causes, and outcome. Radiology, April 1, 2006; 239(1): 61 - 70. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. C. Riedl, G. Pfarl, M. Memarsadeghi, T. Wagner, F. Fitzal, M. Rudas, and T. H. Helbich Lesion Miss Rates and False-Negative Rates for 1115 Consecutive Cases of Stereotactically Guided Needle-localized Open Breast Biopsy with Long-term Follow-up Radiology, December 1, 2005; 237(3): 847 - 853. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. You, E.-K. Kim, J. Y. Kwak, M. J. Kim, K. K. Oh, B.-W. Park, and W. I. Yang Focal Fibrosis of the Breast Diagnosed by a Sonographically Guided Core Biopsy of Nonpalpable Lesions: Imaging Findings and Clinical Relevance J. Ultrasound Med., October 1, 2005; 24(10): 1377 - 1384. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Koskela, M. Sudah, M. H. Berg, V. J. Karja, P. K. Mustonen, V. Kataja, and R. S. Vanninen Add-on Device for Stereotactic Core-Needle Breast Biopsy: How Many Biopsy Specimens Are Needed for a Reliable Diagnosis? Radiology, September 1, 2005; 236(3): 801 - 809. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy Radiology, September 1, 2004; 232(3): 897 - 903. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. S. Burnside, D. L. Rubin, R. D. Shachter, R. E. Sohlich, and E. A. Sickles A Probabilistic Expert System That Provides Automated Mammographic-Histologic Correlation: Initial Experience Am. J. Roentgenol., February 1, 2004; 182(2): 481 - 488. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. B. Gordon, F. A. Gagnon, and L. Lanzkowsky Solid Breast Masses Diagnosed as Fibroadenoma at Fine-Needle Aspiration Biopsy: Acceptable Rates of Growth at Long-term Follow-up Radiology, October 1, 2003; 229(1): 233 - 238. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J. Kirshenbaum, T. Voruganti, C. Overbeeke, M. D. Kirshenbaum, P. Patel, G. Kaplan, V. Maker, C. August, and R. P. Cavallino Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions Using a Conventional Mammography Unit with an Add-On Device Am. J. Roentgenol., August 1, 2003; 181(2): 527 - 531. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Jackman and F. A. Marzoni Jr. Stereotactic Histologic Biopsy with Patients Prone: Technical Feasibility in 98% of Mammographically Detected Lesions Am. J. Roentgenol., March 1, 2003; 180(3): 785 - 794. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman and H. S. Cody III Percutaneous Biopsy and Sentinel Lymphadenectomy: Minimally Invasive Diagnosis and Treatment of Nonpalpable Breast Cancer Am. J. Roentgenol., October 1, 2001; 177(4): 887 - 891. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. R. Margolin, J. W. T. Leung, R. P. Jacobs, and S. R. Denny Percutaneous Imaging-Guided Core Breast Biopsy: 5 Years' Experience in a Community Hospital Am. J. Roentgenol., September 1, 2001; 177(3): 559 - 564. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Sklair-Levy, T. H. Samuels, C. Catzavelos, P. Hamilton, and R. Shumak Stromal Fibrosis of the Breast Am. J. Roentgenol., September 1, 2001; 177(3): 573 - 577. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Brenner, L. W. Bassett, L. L. Fajardo, D. D. Dershaw, W. P. Evans III, R. Hunt, C. Lee, I. Tocino, P. Fisher, M. McCombs, et al. Stereotactic Core-Needle Breast Biopsy: A Multi-institutional Prospective Trial Radiology, March 1, 2001; 218(3): 866 - 872. [Abstract] [Full Text] |
||||
![]() |
L. Liberman, L. A. Ernberg, A. Heerdt, M. F. Zakowski, E. A. Morris, L. R. LaTrenta, A. F. Abramson, and D. D. Dershaw Palpable Breast Masses: Is There a Role for Percutaneous Imaging-Guided Core Biopsy? Am. J. Roentgenol., September 1, 2000; 175(3): 779 - 787. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Guenin, C. H. Lee, L. E. Philpotts, L. J. Horvath, and I. Tocino The Low False-Negative Rate for Stereotactic Breast Biopsy Dr Lee and colleagues respond: Radiology, August 1, 2000; 216(2): 609 - 610. [Full Text] |
||||
![]() |
L. Liberman and M. P. Sama Cost-Effectiveness of Stereotactic 11-Gauge Directional Vacuum-Assisted Breast Biopsy Am. J. Roentgenol., July 1, 2000; 175(1): 53 - 58. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199. [Full Text] [PDF] |
||||
![]() |
Follow-up After Benign Stereotactic Breast Biopsy Journal Watch (General), July 20, 1999; 1999(720): 5 - 5. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |