Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Neri, E.
Right arrow Articles by Bartolozzi, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Neri, E.
Right arrow Articles by Bartolozzi, C.
(Radiology. 1999;212:276-279.)
© RSNA, 1999


Technical Developments

Virtual CT Intravascular Endoscopy of the Aorta: Pierced Surface and Floating Shape Thresholding Artifacts1

Emanuele Neri, MD, Davide Caramella, MD, Fabio Falaschi, MD, Paola Sbragia, MD, Claudio Vignali, MD, Edoardo Laiolo, MD, Adriano Viviani, MD and Carlo Bartolozzi, MD

1 From the Department of Oncology, Diagnostic and Interventional Radiology, University of Pisa, Via Roma 67, I-56100 Pisa, Italy. Received December 15, 1997; revision requested March 2, 1998; final revision received November 6; accepted January 19, 1999. Address reprint requests to E.N. (e-mail: neri@do.med.unipi.it).

Two types of artifacts may appear in virtual computed tomographic endoscopic views of the aorta rendered at different threshold levels: pierced surface and floating shape artifacts. A positive correlation was found between mean attenuation of the aorta and the threshold levels at which these artifacts appeared. The correlation was statistically significant (0.71 <= r <= 0.86) for floating shape. An artifact-free threshold range can be predicted on the basis of aortic enhancement.

Index terms: Aorta, CT, 56.12115, 56.12116, 56.12117 • Aortography, virtual, 56.12117 • Computed tomography (CT), image display and recording, 56.12116, 56.12117 • Computed tomography (CT), three-dimensional, 56.12117




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
F. Hornero, V. Cervera, J. Estornell, I. Rodriguez, J. A. Buendia, J. M. Esteban, and J. A. Montero
Virtual Vascular Endoscopy for Acute Aortic Dissection
Ann. Thorac. Surg., August 1, 2005; 80(2): 708 - 710.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N Rilinger, H Seifarth, R Sokiranski, S Kramer, F Liewald, J Goerich, A Tomzcak, and C E E Nierhoff
Virtual intra-arterial angioscopy (VIA) of the carotid artery based on helical CT data
Br. J. Radiol., November 1, 2003; 76(911): 792 - 797.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. F. Glockner
Navigating the Aorta: MR Virtual Vascular Endoscopy
RadioGraphics, March 1, 2003; 23(2): e11 - e11.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
E. Neri, P. Boraschi, D. Caramella, L. Battolla, R. Gigoni, N. Armillotta, G. Braccini, and C. Bartolozzi
MR Virtual Endoscopy of the Upper Urinary Tract
Am. J. Roentgenol., December 1, 2000; 175(6): 1697 - 1702.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1999 by the Radiological Society of North America.