1 From the Departments of Radiology (H.Y., Y.M., P.M., A.H.D.) and Medicine (D.T.R.), University of Chicago, 5841 S Maryland Ave, MC2026, Chicago, IL 60637. Received February 22, 2001; revision requested March 21; revision received June 26; accepted July 27. Supported in part by a grant from the University of Chicago Cancer Research Center. Address correspondence to H.Y. (e-mail: yoshida@uchicago.edu).
PURPOSE: To develop a computer-aided diagnosis (CAD) scheme for automated detection of colonic polyps on the basis of volumetric features and to assess its accuracy on the basis of colonoscopy, the standard.
MATERIALS AND METHODS: Computed tomographic (CT) colonography was performed in patients with use of standard bowel cleansing, air insufflation, and helical scanning in supine and prone positions. The colon was extracted from volumetric data sets generated from transverse CT sections. Volumetric features characterizing polyps were computed at each point in the extracted colon. Polyps were detected by means of hysteresis thresholding and fuzzy clustering followed by a rule-based test on the basis of feature values. Locations of the detected polyps were compared with those detected at conventional colonoscopy.
RESULTS: Forty-one cases were analyzed: nine cases with polyps and 32 without polyps. Each case with polyps had one polyp of clinically important size (six were 59 mm; three, 10 mm). Thus, there were 82 volumetric data sets, 18 included polyps. Eighty-nine percent (16 of 18) of the polyps were detected. Each of the two false-negative findings was detected in the other position; thus, 100% of polyp cases were detected, with 2.5 false-positive findings per patient. The false-positive findings were similar to those due to common perceptual errors. Most of the false-positive findings were easily distinguishable from true polyps by experienced radiologists.
CONCLUSION: The CAD scheme has the potential to depict polyps with high sensitivity and an acceptable false-positive rate.
Index terms: Colon, CT, 75.12115, 75.12117, 75.12119 Colon neoplasms, 75.311 Computers, diagnostic aid Images, analysis, 75.12115, 75.12117, 75.12119
This article has been cited by other articles:
![]() |
S. H. Kim, J. M. Lee, C.-I. Shin, H. C. Kim, J.-G. Lee, J. H. Kim, J. Y. Choi, H. W. Eun, J. K. Han, J. Y. Lee, et al. Effects of Spatial Resolution and Tube Current on Computer-aided Detection of Polyps on CT Colonographic Images: Phantom Study Radiology, August 1, 2008; 248(2): 492 - 503. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A. Taylor, R. Greenhalgh, R. Ilangovan, E. Tam, V. A. Sahni, D. Burling, J. Zhang, P. Bassett, P. J. Pickhardt, and S. Halligan CT Colonography and Computer-aided Detection: Effect of False-Positive Results on Reader Specificity and Reading Efficiency in a Low-Prevalence Screening Population Radiology, April 1, 2008; 247(1): 133 - 140. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Sosna, T. Sella, O. Sy, P. T. Lavin, R. Eliahou, S. Fraifeld, and E. Libson Critical Analysis of the Performance of Double-Contrast Barium Enema for Detecting Colorectal Polyps >= 6 mm in the Era of CT Colonography Am. J. Roentgenol., February 1, 2008; 190(2): 374 - 385. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Robinson, S. Halligan, S. A. Taylor, S. Mallett, and D. G. Altman CT Colonography: A Systematic Review of Standard of Reporting for Studies of Computer-aided Detection Radiology, February 1, 2008; 246(2): 426 - 433. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A. Taylor, S. C. Charman, P. Lefere, E. G. McFarland, E. K. Paulson, J. Yee, R. Aslam, J. M. Barlow, A. Gupta, D. H. Kim, et al. CT Colonography: Investigation of the Optimum Reader Paradigm by Using Computer-aided Detection Software Radiology, December 19, 2007; (2007) 2461070190. [Abstract] [Full Text] |
||||
![]() |
M. E. Baker, L. Bogoni, N. A. Obuchowski, C. Dass, R. M. Kendzierski, E. M. Remer, D. M. Einstein, P. Cathier, A. Jerebko, S. Lakare, et al. Computer-aided Detection of Colorectal Polyps: Can It Improve Sensitivity of Less-Experienced Readers? Preliminary Findings Radiology, October 1, 2007; 245(1): 140 - 149. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. J. Parrish Volume CT: State-of-the-Art Reporting Am. J. Roentgenol., September 1, 2007; 189(3): 528 - 534. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Kim, J. M. Lee, J.-G. Lee, J. H. Kim, P. A. Lefere, J. K. Han, and B. I. Choi Computer-Aided Detection of Colonic Polyps at CT Colonography Using a Hessian Matrix-Based Algorithm: Preliminary Study Am. J. Roentgenol., July 1, 2007; 189(1): 41 - 51. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. D. O'Connor, R. M. Summers, J. Yao, P. J. Pickhardt, and J. R. Choi CT Colonography with Computer-aided Polyp Detection: Volume and Attenuation Thresholds to Reduce False-Positive Findings Owing to the Ileocecal Valve Radiology, November 1, 2006; 241(2): 426 - 432. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Shi, P. Schraedley-Desmond, S. Napel, E. W. Olcott, R. B. Jeffrey Jr, J. Yee, M. E. Zalis, D. Margolis, D. S. Paik, A. J. Sherbondy, et al. CT Colonography: Influence of 3D Viewing and Polyp Candidate Features on Interpretation with Computer-aided Detection. Radiology, June 1, 2006; 239(3): 768 - 776. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A. Taylor, S. Halligan, A. Slater, V. Goh, D. N. Burling, M. E. Roddie, L. Honeyfield, J. McQuillan, H. Amin, and J. Dehmeshki Polyp Detection with CT Colonography: Primary 3D Endoluminal Analysis versus Primary 2D Transverse Analysis with Computer-assisted Reader Software Radiology, June 1, 2006; 239(3): 759 - 767. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Iinuma, N. Moriyama, M. Satake, K. Miyakawa, U. Tateishi, N. Uchiyama, T. Akasu, T. Fujii, and T. Kobayashi Vascular Virtual Endoluminal Visualization of Invasive Colorectal Cancer on MDCT Colonography Am. J. Roentgenol., April 1, 2005; 184(4): 1194 - 1198. [Abstract] [Full Text] [PDF] |
||||
![]() |
K Doi Current status and future potential of computer-aided diagnosis in medical imaging Br. J. Radiol., January 1, 2005; 78(suppl_1): S3 - s19. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. M. Vos, R. E. van Gelder, I. W. O. Serlie, J. Florie, C. Y. Nio, A. S. Glas, F. H. Post, R. Truyen, F. A. Gerritsen, and J. Stoker Three-dimensional Display Modes for CT Colonography: Conventional 3D Virtual Colonoscopy versus Unfolded Cube Projection Radiology, September 1, 2003; 228(3): 878 - 885. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. D. Johnson Hard- versus Soft-Copy Interpretation Radiology, June 1, 2003; 227(3): 629 - 630. [Full Text] [PDF] |
||||
![]() |
A. M. Evancho, H. Yoshida, and A. Dachman Computer-aided Diagnosis: Blessing or Curse? * Drs Yoshida and Dachman respond: Radiology, November 1, 2002; 225(2): 606 - 607. [Full Text] [PDF] |
||||
![]() |
J. Yee CT Screening for Colorectal Cancer RadioGraphics, November 1, 2002; 22(6): 1525 - 1531. [Full Text] [PDF] |
||||
![]() |
H. Yoshida, J. Nappi, P. MacEneaney, D. T. Rubin, and A. H. Dachman Computer-aided Diagnosis Scheme for Detection of Polyps at CT Colonography RadioGraphics, July 1, 2002; 22(4): 963 - 979. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |