Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2251010698
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Johansson, L.
Right arrow Articles by Ahlström, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johansson, L.
Right arrow Articles by Ahlström, H.
(Radiology 2002;225:97-103.)
© RSNA, 2002


Experimental Studies

Acute Cardiac Transplant Rejection: Detection and Grading with MR Imaging with a Blood Pool Contrast Agent—Experimental Study in the Rat1

Lars Johansson, MD, Cecilia Johnsson, PhD, Eva Penno, MD, Atle Björnerud, MSc and Håkan Ahlström, MD, PhD

1 From the Departments of Diagnostic Radiology (L.J., E.P., H.A.) and Transplantation Surgery (C.J.), Uppsala University Hospital, Magnetkameran Ing 24, 751 85 Uppsala, Sweden; and Nycomed Amersham Imaging, Oslo, Norway (L.J., A.B.). Received March 29, 2001; revision requested May 21; final revision received March 5, 2002; accepted March 22. Supported in part by a grant from Nycomed Amersham and by the Swedish Medical Research Council project K2001-04X-06676-19A. Address correspondence to L.J. (e-mail: lars.johansson@radiol.uu.se).

PURPOSE: To investigate the possibility of detecting cardiac transplant rejection and determining its degree of severity with magnetic resonance (MR) imaging with a blood pool contrast agent.

MATERIALS AND METHODS: Rat allogeneic (PVG to Wistar/Kyoto, n = 9) and syngeneic (Wistar/Kyoto to Wistar/Kyoto, n = 6) heterotopic heart transplantations were performed. On the 2nd and 6th postoperative days, an ultrasmall superparamagnetic iron oxide, or USPIO, contrast agent was injected intravenously at a dose of 2 mg of iron per kilogram of body weight. The injection was followed by three-dimensional T1-weighted MR imaging of the heart grafts with an imaging time of approximately 2 minutes for each image for 44 minutes. The signal intensity (SI) was measured in the myocardium over time, and the relative enhancement was calculated. After the 6th day, the rats were sacrificed, and the morphology of the transplanted hearts was assessed histologically. The CIs for the difference of the means on day 2 and day 6 were calculated by using a bootstrap technique, and the correlation between the relative SI change and the histologically determined degree of rejection were calculated with the Spearman rank order correlation coefficient.

RESULTS: On day 6, a statistically significant difference between the groups was found at 4 minutes after injection of the contrast agent and increased with increasing time after injection. The mean percentage change in SI at the last time point for the allogeneic group on day 2 was -8.7% (SD, 8.5) and for the syngeneic group was -6.6% (SD, 6.0). On day 6, the allogeneic group had a relative SI change of 17.7% (SD, 8.7), whereas the syngeneic group had a change of -7.4% (SD, 2.6). There was a significant difference between only the two groups on day 6 (P < .001). Furthermore, in the allogeneic group the histologically determined degree of rejection correlated positively with the relative SI enhancement (r = 0.89, P < .005).

CONCLUSION: Acutely rejecting heart transplants can be distinguished from nonrejecting ones in an animal model with MR imaging and a blood pool contrast agent. In addition, the relative SI enhancement reflects the histologically determined degree of rejection.

© RSNA, 2002

Index terms: Heart, MR, 51.121412, 51.12143, 51.12144, 51.12146 • Heart, transplantation, 51.459 • Iron • Magnetic resonance (MR), contrast enhancement, 51.121412, 51.12143







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2002 by the Radiological Society of North America.