Medical Physics |
1 From the Department of Diagnostic and Interventional Radiology, University Hospital Essen, Hufelandstrasse 55, 45122 Essen, Germany. From the 2001 RSNA scientific assembly. Received August 13, 2001; revision requested September 26; final revision received April 8, 2002; accepted May 23. Address correspondence to J.B. (e-mail: joerg.barkhausen@uni-essen.de).
PURPOSE: To measure the effective radiation doses delivered at electron-beam computed tomography (CT) and multidetector row spiral CT of coronary arteries and to compare these doses with those delivered at catheter coronary angiography.
MATERIALS AND METHODS: An anthropomorphic phantom equipped with 66 thermoluminescent dosimeters was imaged at cardiac CT. Four protocols for unenhanced coronary artery calcium scoring were simulated: one with electron-beam CT and three with multidetector row CT. Four similar protocols for coronary CT angiography were simulated. All multidetector row spiral CT protocols were performed with retrospective electrocardiographic triggering. Biplane catheter coronary angiography also was simulated. Radiation doses to organs were measured, and effective doses were calculated according to guidelines published in International Commission on Radiological Protection Publication 60.
RESULTS: Coronary artery calcium scoring with electron-beam CT yielded effective radiation doses of 1.0 and 1.3 mSv for male and female patients, respectively. The radiation doses at calcium scoring with multidetector row CT were 1.55.2 mSv for male patients and 1.86.2 mSv for female patients. Electron-beam CT coronary angiography yielded effective doses of 1.5 and 2.0 mSv for male and female patients, respectively. The highest effective doses were delivered at multidetector row CT angiography: 6.710.9 mSv for male patients and 8.113.0 mSv for female patients. Catheter coronary angiography yielded effective doses of 2.1 and 2.5 mSv for male and female patients, respectively.
CONCLUSION: Higher radiation doses are delivered at multidetector row cardiac CT compared with the doses delivered at electron-beam CT and catheter coronary angiography.
© RSNA, 2002
Index terms: Computed tomography (CT), electron beam, 54.12111, 54.12112, 54.12115, 54.12116 Computed tomography (CT), multidetector row, 54.12111, 54.12112, 54.12115, 54.12116 Computed tomography (CT), radiation exposure, 54.12111, 54.12112, 54.12115, 54.12116 Coronary vessels, CT, 54.12111, 54.12112, 54.12115, 54.12116 Dosimetry
This article has been cited by other articles:
![]() |
A. Schmermund, B. Nowak, and T. Voigtlander Non-invasive CT coronary angiography: can high diagnostic image quality be achieved with less radiation exposure? Eur. Heart J., December 2, 2008; 29(24): 2955 - 2956. [Full Text] [PDF] |
||||
![]() |
N. Hirai, J. Horiguchi, C. Fujioka, M. Kiguchi, H. Yamamoto, N. Matsuura, T. Kitagawa, H. Teragawa, N. Kohno, and K. Ito Prospective versus Retrospective ECG-gated 64-Detector Coronary CT Angiography: Assessment of Image Quality, Stenosis, and Radiation Dose Radiology, August 1, 2008; 248(2): 424 - 430. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. Bluemke, S. Achenbach, M. Budoff, T. C. Gerber, B. Gersh, L. D. Hillis, W. G. Hundley, W. J. Manning, B. F. Printz, M. Stuber, et al. Noninvasive Coronary Artery Imaging: Magnetic Resonance Angiography and Multidetector Computed Tomography Angiography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention, and the Councils on Clinical Cardiology and Cardiovascular Disease in the Young Circulation, July 29, 2008; 118(5): 586 - 606. [Full Text] [PDF] |
||||
![]() |
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog Radiology, July 1, 2008; 248(1): 254 - 263. [Abstract] [Full Text] [PDF] |
||||
![]() |
M S KRISHNAM, A TOMASIAN, M. Iv, S G RUEHM, R SALEH, C PANKNIN, and J G GOLDIN Left ventricular ejection fraction using 64-slice CT coronary angiography and new evaluation software: initial experience Br. J. Radiol., June 1, 2008; 81(966): 450 - 455. [Abstract] [Full Text] [PDF] |
||||
![]() |
E J HALL and D J BRENNER Cancer risks from diagnostic radiology Br. J. Radiol., May 1, 2008; 81(965): 362 - 378. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Eichhorn, C. Jourdan, S. L. Hill, S. V. Raman, J. P. Cheatham, and F. R. Long CT of Pediatric Vascular Stents Used to Treat Congenital Heart Disease Am. J. Roentgenol., May 1, 2008; 190(5): 1241 - 1246. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. M. Kim, M. J. Chung, K. S. Lee, Y. H. Choe, C. A. Yi, and B.-K. Choe Coronary Calcium Screening Using Low-Dose Lung Cancer Screening: Effectiveness of MDCT with Retrospective Reconstruction Am. J. Roentgenol., April 1, 2008; 190(4): 917 - 922. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Gottlieb and J. A.C. Lima Screening High-Risk Patients With Computed Tomography Angiography Circulation, March 11, 2008; 117(10): 1318 - 1332. [Full Text] [PDF] |
||||
![]() |
C. M. Kramer All High-Risk Patients Should Not Be Screened With Computed Tomographic Angiography Circulation, March 11, 2008; 117(10): 1333 - 1339. [Full Text] [PDF] |
||||
![]() |
B. K. Courtney, N. R. Munce, K. J. Anderson, A. S. Thind, G. Leung, P. E. Radau, F. S. Foster, I. A. Vitkin, R. S. Schwartz, A. J. Dick, et al. Innovations in imaging for chronic total occlusions: a glimpse into the future of angiography's blind-spot Eur. Heart J., March 1, 2008; 29(5): 583 - 593. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P. Earls, E. L. Berman, B. A. Urban, C. A. Curry, J. L. Lane, R. S. Jennings, C. C. McCulloch, J. Hsieh, and J. H. Londt Prospectively Gated Transverse Coronary CT Angiography versus Retrospectively Gated Helical Technique: Improved Image Quality and Reduced Radiation Dose Radiology, March 1, 2008; 246(3): 742 - 753. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Schroeder, S. Achenbach, F. Bengel, C. Burgstahler, F. Cademartiri, P. de Feyter, R. George, P. Kaufmann, A. F. Kopp, J. Knuuti, et al. Cardiac computed tomography: indications, applications, limitations, and training requirements: Report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology Eur. Heart J., February 2, 2008; 29(4): 531 - 556. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Marcassa, J. J. Bax, F. Bengel, B. Hesse, C. L. Petersen, E. Reyes, R. Underwood, and on behalf of the European Council of Nuclear Cardi Clinical value, cost-effectiveness, and safety of myocardial perfusion scintigraphy: a position statement Eur. Heart J., February 2, 2008; 29(4): 557 - 563. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Horiguchi, M. Kiguchi, C. Fujioka, Y. Shen, R. Arie, K. Sunasaka, and K. Ito Radiation Dose, Image Quality, Stenosis Measurement, and CT Densitometry Using ECG-Triggered Coronary 64-MDCT Angiography: A Phantom Study Am. J. Roentgenol., February 1, 2008; 190(2): 315 - 320. [Abstract] [Full Text] [PDF] |
||||
![]() |
G Pundziute, J D Schuijf, J W Jukema, J M van Werkhoven, E Boersma, A de Roos, E E van der Wall, and J J Bax Gender influence on the diagnostic accuracy of 64-slice multislice computed tomography coronary angiography for detection of obstructive coronary artery disease Heart, January 1, 2008; 94(1): 48 - 52. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Rutten, I. Isgum, and M. Prokop Coronary Calcification: Effect of Small Variation of Scan Starting Position on Agatston, Volume, and Mass Scores Radiology, December 1, 2007; 246(1): 90 - 98. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Hamon, R. Morello, J. W. Riddell, and M. Hamon Coronary Arteries: Diagnostic Performance of 16- versus 64-Section Spiral CT Compared with Invasive Coronary Angiography Meta-Analysis Radiology, December 1, 2007; 245(3): 720 - 731. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Burrill, Z. Dabbagh, F. Gollub, and M. Hamady Multidetector computed tomographic angiography of the cardiovascular system Postgrad. Med. J., November 1, 2007; 83(985): 698 - 704. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. D. Cody and M. Mahesh AAPM/RSNA Physics Tutorials AAPM/RSNA Physics Tutorial for Residents: Technologic Advances in Multidetector CT with a Focus on Cardiac Imaging RadioGraphics, November 1, 2007; 27(6): 1829 - 1837. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. T. Wilson, P. Gopalakrishnan, and T. Tak Noninvasive Cardiac Imaging with Computed Tomography Clin. Med. Res., October 1, 2007; 5(3): 165 - 171. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Einstein, K. W. Moser, R. C. Thompson, M. D. Cerqueira, and M. J. Henzlova Radiation Dose to Patients From Cardiac Diagnostic Imaging Circulation, September 11, 2007; 116(11): 1290 - 1305. [Full Text] [PDF] |
||||
![]() |
M. Mahesh and D. D. Cody AAPM/RSNA Physics Tutorial for Residents: Physics of Cardiac Imaging with Multiple-Row Detector CT RadioGraphics, September 1, 2007; 27(5): 1495 - 1509. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Hur, S. W. Hong, S. Y. Kim, Y. H. Kim, Y. J. Hwang, W. R. Lee, and S. J. Cha Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography Am. J. Roentgenol., July 1, 2007; 189(1): 188 - 196. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Schlosser, P. Hunold, T. Voigtlander, A. Schmermund, and J. Barkhausen Coronary Artery Calcium Scoring: Influence of Reconstruction Interval and Reconstruction Increment Using 64-MDCT Am. J. Roentgenol., April 1, 2007; 188(4): 1063 - 1068. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. Jones, T. Athanasiou, N. Dunne, J. Kirby, O. Aziz, A. Haq, C. Rao, V. Constantinides, S. Purkayastha, and A. Darzi Multi-Detector Computed Tomography in Coronary Artery Bypass Graft Assessment: A Meta-Analysis Ann. Thorac. Surg., January 1, 2007; 83(1): 341 - 348. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Schoder and M. Gonen Screening for Cancer with PET and PET/CT: Potential and Limitations J. Nucl. Med., January 1, 2007; 48(1_suppl): 4S - 18S. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Dogan, L. J. M. Kroft, M. V. Huisman, R. J. van der Geest, and A. de Roos Right Ventricular Function in Patients with Acute Pulmonary Embolism: Analysis with Electrocardiography-synchronized Multi-Detector Row CT Radiology, December 1, 2006; 242(1): 78 - 84. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Achenbach Computed Tomography Coronary Angiography J. Am. Coll. Cardiol., November 21, 2006; 48(10): 1919 - 1928. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Hamon, G. G.L. Biondi-Zoccai, P. Malagutti, P. Agostoni, R. Morello, M. Valgimigli, and M. Hamon Diagnostic Performance of Multislice Spiral Computed Tomography of Coronary Arteries as Compared With Conventional Invasive Coronary Angiography: A Meta-Analysis J. Am. Coll. Cardiol., November 7, 2006; 48(9): 1896 - 1910. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Budoff, S. Achenbach, R. S. Blumenthal, J. J. Carr, J. G. Goldin, P. Greenland, A. D. Guerci, J. A.C. Lima, D. J. Rader, G. D. Rubin, et al. Assessment of Coronary Artery Disease by Cardiac Computed Tomography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology Circulation, October 17, 2006; 114(16): 1761 - 1791. [Full Text] [PDF] |
||||
![]() |
T. K Mittal, M. Barbir, and M. Rubens Role of computed tomography in risk assessment for coronary heart disease. Postgrad. Med. J., October 1, 2006; 82(972): 664 - 671. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. Jones, T. Athanasiou, N. Dunne, J. Kirby, S. Attaran, A. Chow, S. Purkayastha, and A. Darzi Multi-slice computed tomography in coronary artery disease. Eur. J. Cardiothorac. Surg., September 1, 2006; 30(3): 443 - 450. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Coche, S. Vynckier, and M. Octave-Prignot Pulmonary Embolism: Radiation Dose with Multi-Detector Row CT and Digital Angiography for Diagnosis Radiology, September 1, 2006; 240(3): 690 - 697. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Horiguchi, H. Yamamoto, N. Hirai, Y. Akiyama, C. Fujioka, K. Marukawa, H. Fukuda, and K. Ito Variability of repeated coronary artery calcium measurements on low-dose ECG-gated 16-MDCT. Am. J. Roentgenol., July 1, 2006; 187(1): W1 - W6. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Nikolaou, A. Knez, C. Rist, B. J. Wintersperger, A. Leber, T. Johnson, M. F. Reiser, and C. R. Becker Accuracy of 64-MDCT in the diagnosis of ischemic heart disease. Am. J. Roentgenol., July 1, 2006; 187(1): 111 - 117. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. M. Feuchtner, W. Dichtl, T. Schachner, S. Muller, A. Mallouhi, G. J. Friedrich, and D. z. Nedden Diagnostic performance of MDCT for detecting aortic valve regurgitation. Am. J. Roentgenol., June 1, 2006; 186(6): 1676 - 1681. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. D. Raptopoulos, P. B. Boiselle, N. Michailidis, J. Handwerker, A. Sabir, J. A. Edlow, I. Pedrosa, and J. B. Kruskal MDCT Angiography of Acute Chest Pain: Evaluation of ECG-Gated and Nongated Techniques Am. J. Roentgenol., June 1, 2006; 186(6_Supplement_2): S346 - S356. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. R. Coles, M. A. Smail, I. S. Negus, P. Wilde, M. Oberhoff, K. R. Karsch, and A. Baumbach Comparison of Radiation Doses From Multislice Computed Tomography Coronary Angiography and Conventional Diagnostic Angiography J. Am. Coll. Cardiol., May 2, 2006; 47(9): 1840 - 1845. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. M. Feuchtner, W. Dichtl, G. J. Friedrich, M. Frick, H. Alber, T. Schachner, J. Bonatti, A. Mallouhi, T. Frede, O. Pachinger, et al. Multislice Computed Tomography for Detection of Patients With Aortic Valve Stenosis and Quantification of Severity J. Am. Coll. Cardiol., April 4, 2006; 47(7): 1410 - 1417. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. V. Anand, E. Lim, A. Lahiri, and J. J. Bax The role of non-invasive imaging in the risk stratification of asymptomatic diabetic subjects Eur. Heart J., April 2, 2006; 27(8): 905 - 912. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Pache, U. Saueressig, A. Frydrychowicz, D. Foell, N. Ghanem, E. Kotter, A. Geibel-Zehender, C. Bode, M. Langer, and T. Bley Initial experience with 64-slice cardiac CT: non-invasive visualization of coronary artery bypass grafts Eur. Heart J., April 2, 2006; 27(8): 976 - 980. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. V. Anand, E. Lim, D. Hopkins, R. Corder, L. J. Shaw, P. Sharp, D. Lipkin, and A. Lahiri Risk stratification in uncomplicated type 2 diabetes: prospective evaluation of the combined use of coronary artery calcium imaging and selective myocardial perfusion scintigraphy Eur. Heart J., March 2, 2006; 27(6): 713 - 721. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. F. Bruzzi, M. Remy-Jardin, D. Delhaye, A. Teisseire, C. Khalil, and J. Remy When, Why, and How to Examine the Heart During Thoracic CT: Part 1, Basic Principles Am. J. Roentgenol., February 1, 2006; 186(2): 324 - 332. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. E. Clouse, J. Chen, H. M. Krumholz, M. E. Clouse, J. Chen, and H. M. Krumholz Noninvasive Screening for Coronary Artery Disease With Computed Tomography Is Useful Circulation, January 3, 2006; 113(1): 125 - 146. [Full Text] [PDF] |
||||
![]() |
J. J. W. Sandstede, J. Stoffels, F. Wendel, C. Ritter, M. Beer, and D. Hahn Different Reconstruction Intervals for Exclusion of Coronary Artery Calcifications by Retrospectively Gated MDCT Am. J. Roentgenol., January 1, 2006; 186(1): 193 - 197. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Schwaiger, S. Ziegler, and S. G. Nekolla PET/CT: Challenge for Nuclear Cardiology J. Nucl. Med., October 1, 2005; 46(10): 1664 - 1678. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Achenbach, D. Ropers, F.-K. Pohle, D. Raaz, J. von Erffa, A. Yilmaz, G. Muschiol, and W. G. Daniel Detection of coronary artery stenoses using multi-detector CT with 16x0.75 collimation and 375 ms rotation Eur. Heart J., October 1, 2005; 26(19): 1978 - 1986. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Schmermund and R. Erbel Non-invasive computed tomographic coronary angiography: the end of the beginning Eur. Heart J., August 1, 2005; 26(15): 1451 - 1453. [Full Text] [PDF] |
||||
![]() |
M. J. Budoff, M. C. Cohen, M. J. Garcia, J. McB. Hodgson, W. G. Hundley, J. A.C. Lima, W. J. Manning, G. M. Pohost, P. M. Raggi, G. P. Rodgers, et al. ACCF/AHA Clinical Competence Statement on Cardiac Imaging With Computed Tomography and Magnetic Resonance: A Report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competence and Training J. Am. Coll. Cardiol., July 19, 2005; 46(2): 383 - 402. [Full Text] [PDF] |
||||
![]() |
J. Datta, C. S. White, R. C. Gilkeson, C. A. Meyer, S. Kansal, M. L. Jani, R. C. Arildsen, and K. Read Anomalous Coronary Arteries in Adults: Depiction at Multi-Detector Row CT Angiography Radiology, June 1, 2005; 235(3): 812 - 818. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Heuschmid, A. Kuettner, S. Schroeder, T. Trabold, A. Feyer, M. D. Seemann, R. Kuzo, C. D. Claussen, and A. F. Kopp ECG-Gated 16-MDCT of the Coronary Arteries: Assessment of Image Quality and Accuracy in Detecting Stenoses Am. J. Roentgenol., May 1, 2005; 184(5): 1413 - 1419. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. R Mollet, F. Cademartiri, and P. J de Feyter Non-invasive multislice CT coronary imaging Heart, March 1, 2005; 91(3): 401 - 407. [Full Text] [PDF] |
||||
![]() |
T. Schlosser, K. Pagonidis, C. U. Herborn, P. Hunold, K.-U. Waltering, T. C. Lauenstein, and J. Barkhausen Assessment of Left Ventricular Parameters Using 16-MDCT and New Software for Endocardial and Epicardial Border Delineation Am. J. Roentgenol., March 1, 2005; 184(3): 765 - 773. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. R. Mollet, F. Cademartiri, G. P. Krestin, E. P. McFadden, C. A. Arampatzis, P. W. Serruys, and P. J. de Feyter Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography J. Am. Coll. Cardiol., January 4, 2005; 45(1): 128 - 132. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. D. Schuijf, J. J. Bax, J. W. Jukema, H. J. Lamb, H. W. Vliegen, L. P. Salm, A. de Roos, and E. E. van der Wall Noninvasive Angiography and Assessment of Left Ventricular Function Using Multislice Computed Tomography in Patients With Type 2 Diabetes Diabetes Care, December 1, 2004; 27(12): 2905 - 2910. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Martuscelli, A. Romagnoli, A. D'Eliseo, M. Tomassini, C. Razzini, M. Sperandio, G. Simonetti, F. Romeo, and J.L. Mehta Evaluation of Venous and Arterial Conduit Patency by 16-Slice Spiral Computed Tomography Circulation, November 16, 2004; 110(20): 3234 - 3238. [Abstract] [Full Text] [PDF] |
||||
|
|