Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print February 28, 2003, 10.1148/radiol.2271011962
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2271011962v1
227/1/192    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Karssemeijer, N.
Right arrow Articles by Holland, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Karssemeijer, N.
Right arrow Articles by Holland, R.
(Radiology 2003;227:192-200.)
© RSNA, 2003


Breast Imaging

Computer-aided Detection versus Independent Double Reading of Masses on Mammograms1

Nico Karssemeijer, PhD, Johannes D. M. Otten, MS, Andre L. M. Verbeek, MD, PhD, Johanna H. Groenewoud, MD, PhD, Harry J. de Koning, MD, PhD, Jan H. C. L. Hendriks, MD, PhD and Roland Holland, MD, PhD

1 From the Departments of Radiology (N.K.) and Epidemiology and Biostatistics (J.D.M.O., A.L.M.V.) and the National Expert and Training Center for Breast Cancer Screening (J.H.C.L.H., R.H.), University Medical Center Nijmegen, Geert Grooteplein 18, 6525 GA Nijmegen, the Netherlands; and the Department of Public Health, National Evaluation Team for Breast Cancer Screening (J.H.G., H.J.d.K.). From the 2001 RSNA scientific assembly. Received November 30, 2001; revision requested January 10, 2002; final revision received August 5; accepted August 22. Supported by the National Evaluation Team for Breast Cancer Screening. Address correspondence to N.K. (e-mail: n.karssemeijer@rad.umcn.nl).

PURPOSE: To evaluate the use of a computer-aided detection (CAD) system (designed for mammographic mass detection) to help improve mass interpretation and to compare CAD results with independent double-reading results.

MATERIALS AND METHODS: Screening mammograms from 500 cases were collected; 125 of these cases were screening-detected cancers, and 125 were interval cancers. Previously obtained screening mammograms (ie, prior mammograms) were available in all cases. All mammograms were analyzed by a CAD system, which detected mass regions and assigned a level of (cancer) suspicion to each mass. Ten experienced screening radiologists read the prior mammograms. For independent interpretation with CAD, the suspicion rating assigned to each finding by the radiologist was weighted with the CAD output at the area of the finding. CAD markers on areas that were not reported by the radiologist were not used. Independent double reading was implemented by using a rule to combine the levels of suspicion assigned to findings by two radiologists. Results were evaluated by using localized-response receiver operating characteristic analysis.

RESULTS: In a total of 141 cases, there was a visible abnormality at the location of the cancer on the prior mammogram, and 115 of these were classified as mass cases. For prior mammograms that depicted masses, the mean sensitivity of the radiologists, as averaged among the false-positive rates lower than 10%, was 39.4%; this increased by 7.0% with CAD and by 10.5% with double reading. Differences among single, double, and CAD readings were statistically significant (P < .001).

CONCLUSION: Although independent double reading yields the best detection performance, the presence and probability of CAD mass markers can improve mammogram interpretation.

© RSNA, 2003

Index terms: Breast neoplasms, diagnosis, 00.31, 00.32 • Cancer screening, 00.11 • Computers, diagnostic aid




This article has been cited by other articles:


Home page
NEJMHome page
F. J. Gilbert, S. M. Astley, M. G.C. Gillan, O. F. Agbaje, M. G. Wallis, J. James, C. R.M. Boggis, S. W. Duffy, and the CADET II Group
Single Reading with Computer-Aided Detection for Screening Mammography
N. Engl. J. Med., October 16, 2008; 359(16): 1675 - 1684.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Georgian-Smith, R. H. Moore, E. Halpern, E. D. Yeh, E. A. Rafferty, H. A. D'Alessandro, M. Staffa, D. A. Hall, K. A. McCarthy, and D. B. Kopans
Blinded Comparison of Computer-Aided Detection with Human Second Reading in Screening Mammography
Am. J. Roentgenol., November 1, 2007; 189(5): 1135 - 1141.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. A. J. Roelofs, N. Karssemeijer, N. Wedekind, C. Beck, S. van Woudenberg, P. R. Snoeren, J. H. C. L. Hendriks, M. Rosselli del Turco, N. Bjurstam, H. Junkermann, et al.
Importance of Comparison of Current and Prior Mammograms in Breast Cancer Screening
Radiology, January 1, 2007; 242(1): 70 - 77.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. M. Ko, M. J. Nicholas, J. B. Mendel, and P. J. Slanetz
Prospective assessment of computer-aided detection in interpretation of screening mammography.
Am. J. Roentgenol., December 1, 2006; 187(6): 1483 - 1491.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. R. Pai, N. E. Gregory, A. E. Swinford, and M. Rebner
Ductal Carcinoma in Situ: Computer-aided Detection in Screening Mammography
Radiology, December 1, 2006; 241(3): 689 - 694.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N Karssemeijer, J D M Otten, H Rijken, and R Holland
Computer aided detection of masses in mammograms as decision support
Br. J. Radiol., December 1, 2006; 79(Special_Issue_2): S123 - S126.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Das, G. Muhlenbruch, A. H. Mahnken, T. G. Flohr, L. Gundel, S. Stanzel, T. Kraus, R. W. Gunther, and J. E. Wildberger
Small Pulmonary Nodules: Effect of Two Computer-aided Detection Systems on Radiologist Performance.
Radiology, November 1, 2006; 241(2): 564 - 571.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. J. Gilbert, S. M. Astley, M. A. McGee, M. G. C. Gillan, C. R. M. Boggis, P. M. Griffiths, and S. W. Duffy
Single Reading with Computer-aided Detection and Double Reading of Screening Mammograms in the United Kingdom National Breast Screening Program
Radiology, October 1, 2006; 241(1): 47 - 53.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Drukker, M. L. Giger, and C. E. Metz
Robustness of Computerized Lesion Detection and Classification Scheme across Different Breast US Platforms
Radiology, December 1, 2005; 237(3): 834 - 840.
[Abstract] [Full Text] [PDF]


Home page
JNCI J Natl Cancer InstHome page
J. D. M. Otten, N. Karssemeijer, J. H. C. L. Hendriks, J. H. Groenewoud, J. Fracheboud, A. L. M. Verbeek, H. J. de Koning, and R. Holland
Effect of Recall Rate on Earlier Screen Detection of Breast Cancers Based on the Dutch Performance Indicators
J Natl Cancer Inst, May 18, 2005; 97(10): 748 - 754.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
K Doi
Current status and future potential of computer-aided diagnosis in medical imaging
Br. J. Radiol., January 1, 2005; 78(suppl_1): S3 - s19.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
J Roehrig
The manufacturer's perspective
Br. J. Radiol., January 1, 2005; 78(suppl_1): S41 - S45.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S M Astley
Computer-based detection and prompting of mammographic abnormalities
Br. J. Radiol., December 1, 2004; 77(suppl_2): S194 - S200.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2003 by the Radiological Society of North America.