Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print May 1, 2003, 10.1148/radiol.2273020369
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2273020369v1
227/3/795    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hong, C.
Right arrow Articles by Pilgram, T. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hong, C.
Right arrow Articles by Pilgram, T. K.
(Radiology 2003;227:795-801.)
© RSNA, 2003


Cardiac Imaging

Coronary Artery Calcium: Accuracy and Reproducibility of Measurements with Multi–Detector Row CT—Assessment of Effects of Different Thresholds and Quantification Methods1

Cheng Hong, MD, PhD, Kyongtae T. Bae, MD, PhD and Thomas K. Pilgram, PhD

1 From the Mallinckrodt Institute of Radiology, Washington University School of Medicine, Campus Box 8131, 510 S Kingshighway Blvd, St Louis, MO 63110. Received April 7, 2002; revision requested June 17; final revision received October 3; accepted October 23. Address correspondence to K.T.B. (e-mail: baet@mir.wustl.edu).

PURPOSE: To evaluate the effects of different thresholds and quantification methods on the accuracy and reproducibility of coronary calcium measurements with multi–detector row computed tomography (CT).

MATERIALS AND METHODS: A cardiac CT phantom containing predetermined calcified cylinders was scanned. Calcium volume and mass were measured at various threshold values ranging from 80 to 230 HU. In 32 patients, two consecutive CT scans were obtained, and the coronary artery calcium score, volume, and mass were measured by one observer at 130- and 90-HU thresholds. Correlation analysis and analysis of variance were performed to evaluate the measurement errors in the phantom study and the interscan variability in the clinical study.

RESULTS: In the phantom, mass measurement error varied with threshold and calcium density (P < .01). Mass error was strongly correlated with volume error (r = 0.91, P < .01) but with a much smaller range. In the clinical study, interscan variability of mass measurements was significantly lower than that with other measurement methods for both patients and individual vessels. For the patients, the mean interscan variability of calcium score, volume, and mass at the 130-HU threshold was 20.4%, 13.9%, and 9.3%, respectively. For all methods, interscan variability was not significantly different between the 130- and 90-HU thresholds (P > .05).

CONCLUSION: The mass measurement is more accurate, less variable, and more reproducible in coronary calcium quantification than are measurements with other algorithms. Accurate quantification of calcium in each calcified plaque may require that the threshold be set individually, depending on the calcium density.

© RSNA, 2003

Index terms: Computed tomography (CT), experimental studies, 54.12119 • Coronary vessels, calcification, 54.12119 • Coronary vessels, CT, 54.12119 • Phantoms




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
S. M. Kim, M. J. Chung, K. S. Lee, Y. H. Choe, C. A. Yi, and B.-K. Choe
Coronary Calcium Screening Using Low-Dose Lung Cancer Screening: Effectiveness of MDCT with Retrospective Reconstruction
Am. J. Roentgenol., April 1, 2008; 190(4): 917 - 922.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Raman, B. Raman, S. Napel, and G. D. Rubin
Semiautomated Quantification of the Mass and Distribution of Vascular Calcification with Multidetector CT: Method and Evaluation
Radiology, April 1, 2008; 247(1): 241 - 250.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Rutten, I. Isgum, and M. Prokop
Coronary Calcification: Effect of Small Variation of Scan Starting Position on Agatston, Volume, and Mass Scores
Radiology, December 1, 2007; 246(1): 90 - 98.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. J. Budoff, S. Achenbach, R. S. Blumenthal, J. J. Carr, J. G. Goldin, P. Greenland, A. D. Guerci, J. A.C. Lima, D. J. Rader, G. D. Rubin, et al.
Assessment of Coronary Artery Disease by Cardiac Computed Tomography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology
Circulation, October 17, 2006; 114(16): 1761 - 1791.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. T. Boll, A. S. Bossert, A. J. Aschoff, M. H. Hoffmann, and R. C. Gilkeson
Synergy of MDCT and Cine MRI for the Evaluation of Cardiac Motility
Am. J. Roentgenol., June 1, 2006; 186(6_Supplement_2): S379 - S386.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. E. Clouse, J. Chen, H. M. Krumholz, M. E. Clouse, J. Chen, and H. M. Krumholz
Noninvasive Screening for Coronary Artery Disease With Computed Tomography Is Useful
Circulation, January 3, 2006; 113(1): 125 - 146.
[Full Text] [PDF]


Home page
CirculationHome page
F. Moselewski, C. J. O'Donnell, S. Achenbach, M. Ferencik, J. Massaro, A. Nguyen, R. C. Cury, S. Abbara, I.-K. Jang, T. J. Brady, et al.
Calcium Concentration of Individual Coronary Calcified Plaques as Measured by Multidetector Row Computed Tomography
Circulation, June 21, 2005; 111(24): 3236 - 3241.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. S. Halliburton, A. E. Stillman, M. Lieber, J. M. Kasper, S. A. Kuzmiak, and R. D. White
Potential Clinical Impact of Variability in the Measurement of Coronary Artery Calcification with Sequential MDCT
Am. J. Roentgenol., February 1, 2005; 184(2): 643 - 648.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. Koos, A. H. Mahnken, A. M. Sinha, J. E. Wildberger, R. Hoffmann, and H. P. Kuhl
Aortic Valve Calcification as a Marker for Aortic Stenosis Severity: Assessment on 16-MDCT
Am. J. Roentgenol., December 1, 2004; 183(6): 1813 - 1818.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Hong, T. K. Pilgram, F. Zhu, and K. T. Bae
Coronary Artery Calcification: Effect of Size of Field of View on Multi-Detector Row CT Measurements
Radiology, October 1, 2004; 233(1): 281 - 285.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. E. Hokanson, T. MacKenzie, G. Kinney, J. K. Snell-Bergeon, D. Dabelea, J. Ehrlich, R. H. Eckel, and M. Rewers
Evaluating Changes in Coronary Artery Calcium: An Analytic Method That Accounts for Interscan Variability
Am. J. Roentgenol., May 1, 2004; 182(5): 1327 - 1332.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. A. Rumberger and L. Kaufman
A Rosetta Stone for Coronary Calcium Risk Stratification: Agatston, Volume, and Mass Scores in 11,490 Individuals
Am. J. Roentgenol., September 1, 2003; 181(3): 743 - 748.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2003 by the Radiological Society of North America.