Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2291020859
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Winer-Muram, H. T.
Right arrow Articles by McGarry, R. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Winer-Muram, H. T.
Right arrow Articles by McGarry, R. C.
(Radiology 2003;229:184-194.)
© RSNA, 2003


Thoracic Imaging

Effect of Varying CT Section Width on Volumetric Measurement of Lung Tumors and Application of Compensatory Equations1

Helen T. Winer-Muram, MD, S. Gregory Jennings, MD, Cristopher A. Meyer, MD, Yun Liang, PhD, Alex M. Aisen, MD, Robert D. Tarver, MD and Ronald C. McGarry, MD

1 From the Departments of Radiology (H.T.W.M., S.G.J., C.A.M., Y.L., A.M.A., R.D.T.) and Radiation Oncology (R.C.M.), Indiana University School of Medicine, Indianapolis. Received July 11, 2002; revision requested August 29; final revision received February 11, 2003; accepted March 3. Address correspondence to H.T.W.M., 11224 Clarkston Rd, Zionsville, IN 46077 (e-mail: hwinermu@iupui.edu).

PURPOSE: To determine how volume measurements of simulated and clinical lung tumors at standard computed tomographic (CT) lung window and level settings vary with section width and to derive and apply compensatory equations.

MATERIALS AND METHODS: Spherical simulated tumors of varying diameters were imaged with varying CT section widths, the images were displayed on a workstation, the cross-sectional area of the tumor on each section was measured by using elliptical and perimeter methods, and the areas were integrated to compute tumor volume. The actual and measured tumor volumes for differing section widths and tumor diameters were compared, and compensatory equations were derived. The equations were applied to contemporaneous chest CT images obtained in patients with stage I lung cancer, and the difference between thick- and thin-section–derived volumes before and after application of the equations was determined.

RESULTS: All simulated tumor volumes were overestimated 11%–278%; overestimation varied directly with section width and inversely with tumor diameter. With both measurement methods, mean thin-section volumes of clinical tumors in 55 patients were significantly smaller (P < .01) than mean thick-section volumes: Mean elliptical measurements were 15,025 mm3 (thin) and 18,037 mm3 (thick), with a 20.0% difference; mean perimeter measurements were 16,164 mm3 (thin) and 20,718 mm3 (thick), with a 22.2% difference. The thin-section–to–thick-section volume difference was larger for the smallest tumors. Thin-section volumes were smaller than thick-section volumes in 53 patients with the elliptical method and in 51 patients with the perimeter method. Applying the equations decreased the difference between thick- and thin-section volumes in 37 (67%) of the 55 patients with the elliptical method and in 41 (74%) patients with the perimeter method. The mean thin-section–to–thick-section volume difference became nonsignificant with the perimeter method but remained significant with the elliptical method.

CONCLUSION: Measured lung tumor volumes vary significantly with varying CT section width; overestimation varies directly with section width and inversely with tumor size. Compensatory equations that are somewhat effective in reducing these effects can be derived.

© RSNA, 2003

Index terms: Computed tomography (CT), experimental studies, 60.12111, 60.12115 • Lung neoplasms, 60.32 • Lung neoplasms, CT, 60.12111, 60.12115 • Thorax, CT, 60.12111, 60.12115




This article has been cited by other articles:


Home page
RadiologyHome page
J. Zhang, S. K. Kang, L. Wang, A. Touijer, and H. Hricak
Distribution of Renal Tumor Growth Rates Determined by Using Serial Volumetric CT Measurements
Radiology, January 1, 2009; 250(1): 137 - 144.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. G. Ravenel, W. M. Leue, P. J. Nietert, J. V. Miller, K. K. Taylor, and G. A. Silvestri
Pulmonary Nodule Volume: Effects of Reconstruction Parameters on Automated Measurements--A Phantom Study
Radiology, May 1, 2008; 247(2): 400 - 408.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
C. Suzuki, H. Jacobsson, T. Hatschek, M. R. Torkzad, K. Boden, Y. Eriksson-Alm, E. Berg, H. Fujii, A. Kubo, and L. Blomqvist
Radiologic Measurements of Tumor Response to Treatment: Practical Approaches and Limitations
RadioGraphics, March 1, 2008; 28(2): 329 - 344.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. K. Gould, J. Fletcher, M. D. Iannettoni, W. R. Lynch, D. E. Midthun, D. P. Naidich, and D. E. Ost
Evaluation of Patients With Pulmonary Nodules: When Is It Lung Cancer?: ACCP Evidence-Based Clinical Practice Guidelines (2nd Edition)
Chest, September 1, 2007; 132(3_suppl): 108S - 130S.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Petrou, L. E. Quint, B. Nan, and L. H. Baker
Pulmonary Nodule Volumetric Measurement Variability as a Function of CT Slice Thickness and Nodule Morphology
Am. J. Roentgenol., February 1, 2007; 188(2): 306 - 312.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Jennings, H. T. Winer-Muram, M. Tann, J. Ying, and I. Dowdeswell
Distribution of Stage I Lung Cancer Growth Rates Determined with Serial Volumetric CT Measurements
Radiology, November 1, 2006; 241(2): 554 - 563.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. T. Winer-Muram
The solitary pulmonary nodule.
Radiology, April 1, 2006; 239(1): 34 - 49.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. R. Goodman, M. Gulsun, L. Washington, P. G. Nagy, and K. L. Piacsek
Inherent Variability of CT Lung Nodule Measurements In Vivo Using Semiautomated Volumetric Measurements.
Am. J. Roentgenol., April 1, 2006; 186(4): 989 - 994.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
U. Tateishi, H. Uno, K. Yonemori, M. Satake, M. Takeuchi, and Y. Arai
Prediction of Lung Adenocarcinoma Without Vessel Invasion: A CT Scan Volumetric Analysis
Chest, November 1, 2005; 128(5): 3276 - 3283.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. M. Goo, T. Tongdee, R. Tongdee, K. Yeo, C. F. Hildebolt, and K. T. Bae
Volumetric Measurement of Synthetic Lung Nodules with Multi-Detector Row CT: Effect of Various Image Reconstruction Parameters and Segmentation Thresholds on Measurement Accuracy
Radiology, June 1, 2005; 235(3): 850 - 856.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. Zhao, L. H. Schwartz, C. S. Moskowitz, L. Wang, M. S. Ginsberg, C. A. Cooper, L. Jiang, and J. P. Kalaigian
Pulmonary Metastases: Effect of CT Section Thickness on Measurement--Initial Experience
Radiology, March 1, 2005; 234(3): 934 - 939.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Jennings, H. T. Winer-Muram, R. D. Tarver, and M. O. Farber
Lung Tumor Growth: Assessment with CT--Comparison of Diameter and Cross-sectional Area with Volume Measurements
Radiology, June 1, 2004; 231(3): 866 - 871.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2003 by the Radiological Society of North America.