Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2321020397
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Spelic, D. C.
Right arrow Articles by Suleiman, O. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Spelic, D. C.
Right arrow Articles by Suleiman, O. H.
(Radiology 2004;232:115-125.)


Special Report

Nationwide Evaluation of X-ray Trends Survey of Abdomen and Lumbosacral Spine Radiography1

David C. Spelic, PhD, Richard V. Kaczmarek, MS and Orhan H. Suleiman, PhD

1 From the Center for Devices and Radiological Health, Division of Mammography Quality and Radiation Programs, U.S. Food and Drug Administration, 1350 Piccard Dr, HFZ-240, Rockville, MD 20850. Received April 3, 2002; revision requested June 12; final revision received January 22, 2004; accepted March 3. Address correspondence to D.C.S. (e-mail: david.spelic@fda.hhs.gov).

Results of the 1995 Nationwide Evaluation of X-ray Trends (NEXT) survey of facilities that perform diagnostic radiographic examinations of the abdomen and lumbosacral spine were compared with those of previous NEXT surveys conducted in 1987 and 1989. A clinically validated radiographic phantom was used in the 1995 survey to capture data about radiation exposure and image quality. Additional data were obtained regarding clinical techniques, facility workloads, x-ray beam quality, film processing quality, and darkroom fog. Mean skin-entrance air kerma for the abdomen examination dropped from 3.2 mGy (in 1987) to 2.8 mGy at hospitals and from 3.4 mGy (in 1989) to 3.0 mGy at nonhospital facilities. Mean skin-entrance air kerma also decreased for the lumbosacral spine examination from 3.7 mGy (in 1987) to 3.3 mGy at hospitals and from 3.8 mGy (in 1989) to 3.2 mGy at nonhospital facilities. The quality of film processing improved, although 58 (18.3%) of 317 surveyed facilities did not meet the Mammography Quality Standards Act standard for film processing quality, compared with 185 (5.9%) of 3,120 mammography facilities inspected in 1995. Finally, 181 (58.0%) of 312 surveyed facilities had darkroom fog levels greater than the Mammography Quality Standards Act standard, compared with 1,426 (16.6%) of 8,605 mammography facilities inspected in 1995.

Index terms: Abdomen, radiography, 70.11 • Dosimetry • Radiations, exposure to patients and personnel • Radiations, measurement • Screens and films • Special Reports • Spine, radiography, 33.11




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
W. E. Muhogora, N. A. Ahmed, A. Almosabihi, J. S. Alsuwaidi, A. Beganovic, O. Ciraj-Bjelac, F. K. Kabuya, A. Krisanachinda, M. Milakovic, G. Mukwada, et al.
Patient Doses in Radiographic Examinations in 12 Countries in Asia, Africa, and Eastern Europe: Initial Results from IAEA Projects
Am. J. Roentgenol., June 1, 2008; 190(6): 1453 - 1461.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2004 by the Radiological Society of North America.