Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2352040515
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nelson, J. C.
Right arrow Articles by Detrano, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nelson, J. C.
Right arrow Articles by Detrano, R.
(Radiology 2005;235:403-414.)
© RSNA, 2005


Cardiac Imaging

Measuring Coronary Calcium on CT Images Adjusted for Attenuation Differences1

Jennifer Clark Nelson, PhD, Richard A. Kronmal, PhD, J. Jeffrey Carr, MD, MS, Michael F. McNitt-Gray, PhD, Nathan D. Wong, PhD, Catherine M. Loria, PhD, Jonathan G. Goldin, MD, PhD, O. Dale Williams, MPH, PhD and Robert Detrano, MD, PhD

1 From the Ctr for Health Studies, Group Health Cooperative, Metropolitan Park East, Suite 1600, 1730 Minor Ave, Seattle, WA 98101 (J.C.N.); Dept of Biostatistics, Univ of Washington, Seattle, Wash (J.C.N., R.A.K.); Dept of Radiology, Wake Forest Univ School of Medicine, Winston-Salem, NC (J.J.C.); Dept of Radiology, David Geffen School of Medicine at UCLA, Los Angeles, Calif (M.F.M.G., J.G.G.); Heart Disease Prevention Program, Div of Cardiology, College of Medicine, Univ of California, Irvine, Calif (N.D.W.); Div of Epidemiology and Clinical Applications, National Heart, Lung, and Blood Institute, Bethesda, Md (C.M.L.); Dept of Medicine, Div of Preventive Medicine, Univ of Alabama at Birmingham, Birmingham, Ala (O.D.W.); and Harbor-UCLA Research and Education Inst, Div of Cardiology, Los Angeles, Calif (R.D.). Received Mar 18, 2004; revision requested May 27; revision received Jun 25; accepted Jul 27. Supported by NHLBI contracts N01-HC-95159 through N01-HC-95165, N01-HC-95169, N01-HC-95095, N01-HC-48047 through N01-HC-48050, and N01-HC-05187. Address correspondence to J.C.N. (e-mail: nelson.jl@ghc.org).

PURPOSE: To quantify scanner and participant variability in attenuation values for computed tomographic (CT) images assessed for coronary calcium and define a method for standardizing attenuation values and calibrating calcium measurements.

MATERIALS AND METHODS: Institutional review board approval and participant informed consent were obtained at all study sites. An image attenuation adjustment method involving the use of available calibration phantom data to define standard attenuation values was developed. The method was applied to images from two population-based multicenter studies: the Coronary Artery Risk Development in Young Adults study (3041 participants) and the Multi-Ethnic Study of Atherosclerosis (6814 participants). To quantify the variability in attenuation, analysis of variance techniques were used to compare the CT numbers of standardized torso phantom regions across study sites, and multivariate linear regression models of participant-specific calibration phantom attenuation values that included participant age, race, sex, body mass index (BMI), smoking status, and site as covariates were developed. To assess the effect of the calibration method on calcium measurements, Pearson correlation coefficients between unadjusted and attenuation-adjusted calcium measurements were computed. Multivariate models were used to examine the effect of sex, race, BMI, smoking status, unadjusted score, and site on Agatston score adjustments.

RESULTS: Mean attenuation values (CT numbers) of a standard calibration phantom scanned beneath participants varied significantly according to scanner and participant BMI (P < .001 for both). Values were lowest for Siemens multi–detector row CT scanners (110.0 HU), followed by GE-Imatron electron-beam (116.0 HU) and GE LightSpeed multi–detector row scanners (121.5 HU). Values were also lower for morbidly obese (BMI, ≥40.0 kg/m2) participants (108.9 HU), followed by obese (BMI, 30.0–39.9 kg/m2) (114.8 HU), overweight (BMI, 25.0–29.9 kg/m2) (118.5 HU), and normal-weight or underweight (BMI, <25.0 kg/m2) (120.1 HU) participants. Agatston score calibration adjustments ranged from –650 to 1071 (mean, –8 ± 50 [standard deviation]) and increased with Agatston score (P < .001). The direction and magnitude of adjustment varied significantly according to scanner and BMI (P < .001 for both) and were consistent with phantom attenuation results in that calibration resulted in score decreases for images with higher phantom attenuation values.

CONCLUSION: Image attenuation values vary by scanner and participant body size, producing calcium score differences that are not due to true calcium burden disparities. Use of calibration phantoms to adjust attenuation values and calibrate calcium measurements in research studies and clinical practice may improve the comparability of such measurements between persons scanned with different scanners and within persons over time.

© RSNA, 2005




This article has been cited by other articles:


Home page
RadiologyHome page
E. R. Brown, R. A. Kronmal, D. A. Bluemke, A. D. Guerci, J. J. Carr, J. Goldin, and R. Detrano
Coronary Calcium Coverage Score: Determination, Correlates, and Predictive Accuracy in the Multi-Ethnic Study of Atherosclerosis
Radiology, June 1, 2008; 247(3): 669 - 675.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
R. Detrano, A. D. Guerci, J. J. Carr, D. E. Bild, G. Burke, A. R. Folsom, K. Liu, S. Shea, M. Szklo, D. A. Bluemke, et al.
Coronary Calcium as a Predictor of Coronary Events in Four Racial or Ethnic Groups
N. Engl. J. Med., March 27, 2008; 358(13): 1336 - 1345.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Chung, R. L. McClelland, R. Katz, J. J. Carr, and M. J. Budoff
Repeatability Limits for Measurement of Coronary Artery Calcified Plaque with Cardiac CT in the Multi-Ethnic Study of Atherosclerosis
Am. J. Roentgenol., February 1, 2008; 190(2): W87 - W92.
[Abstract] [Full Text] [PDF]


Home page
Am J EpidemiolHome page
T. Y. Wong, N. Cheung, F. M. A. Islam, R. Klein, M. H. Criqui, M. F. Cotch, J. J. Carr, B. E. K. Klein, and A. R. Sharrett
Relation of Retinopathy to Coronary Artery Calcification: The Multi-Ethnic Study of Atherosclerosis
Am. J. Epidemiol., January 1, 2008; 167(1): 51 - 58.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. A. Kronmal, R. L. McClelland, R. Detrano, S. Shea, J. A. Lima, M. Cushman, D. E. Bild, and G. L. Burke
Risk Factors for the Progression of Coronary Artery Calcification in Asymptomatic Subjects: Results From the Multi-Ethnic Study of Atherosclerosis (MESA)
Circulation, May 29, 2007; 115(21): 2722 - 2730.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. A. Birnbaum, N. Hindman, J. Lee, and J. S. Babb
Multi-Detector Row CT Attenuation Measurements: Assessment of Intra- and Interscanner Variability with an Anthropomorphic Body CT Phantom
Radiology, January 1, 2007; 242(1): 109 - 119.
[Abstract] [Full Text] [PDF]


Home page
Am J EpidemiolHome page
J. C. Nelson, X.-C. Jiang, I. Tabas, A. Tall, and S. Shea
Plasma Sphingomyelin and Subclinical Atherosclerosis: Findings from the Multi-Ethnic Study of Atherosclerosis
Am. J. Epidemiol., May 15, 2006; 163(10): 903 - 912.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. L. McClelland, H. Chung, R. Detrano, W. Post, and R. A. Kronmal
Distribution of Coronary Artery Calcium by Race, Gender, and Age: Results from the Multi-Ethnic Study of Atherosclerosis (MESA)
Circulation, January 3, 2006; 113(1): 30 - 37.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. C. Detrano, M. Anderson, J. Nelson, N. D. Wong, J. J. Carr, M. McNitt-Gray, and D. E. Bild
Coronary Calcium Measurements: Effect of CT Scanner Type and Calcium Measure on Rescan Reproducibility--MESA Study
Radiology, August 1, 2005; 236(2): 477 - 484.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2005 by the Radiological Society of North America.