Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print August 14, 2006, 10.1148/radiol.2411050292
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2411050292v1
241/1/125    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wessling, J.
Right arrow Articles by Heindel, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wessling, J.
Right arrow Articles by Heindel, W.
(Radiology 2006;241:125-131.)
© RSNA, 2006


Experimental Studies

Detection of Colorectal Polyps: Comparison of Multi–Detector Row CT and MR Colonography in a Colon Phantom1

Johannes Wessling, MD, Roman Fischbach, MD, Alexandra Borchert, MD, Harald Kugel, PhD, Thomas Allkemper, MD, Nani Osada, PhD and Walter Heindel, MD

1 From the Departments of Clinical Radiology (J.W., R.F., A.B., H.K., T.A., W.H.) and Medical Informatics and Biomathematics (N.O.), University of Muenster, Albert-Schweitzer-Str 33, 48149 Muenster, Germany. Received February 20, 2005; revision requested April 19; revision received August 3; accepted September 1; final version accepted January 3, 2006. Address correspondence to J.W. (e-mail: weslingj{at}uni-muenster.de).

Purpose: To compare multi–detector row (four- and 16-section) computed tomography (CT), including a low-dose protocol, with high-field-strength (1.5- and 3.0-T) magnetic resonance (MR) imaging for reader detection of colorectal polyps in a colon phantom.

Materials and Methods: A colon phantom with simulated haustral folds and 10 polyps of varying size (2.0–8.0 mm) was imaged at four- and 16-section CT (section thicknesses of 1.25 and 0.75 mm, reconstruction increments of 0.8 and 0.7 mm, and 100 and 10 mAs, respectively, and 120 kV for both) and at 1.5- and 3.0-T MR imaging (three-dimensional gradient-recalled echo sequence, section thickness of 1.4 mm). Three-dimensional endoluminal images were assessed by 10 reviewers for each modality regarding polyp detection. Comparisons of sensitivities were performed by using logistic regression.

Results: Overall, polyps were detected with a sensitivity of 87% (95% confidence interval [CI]: 80%, 94%) at four-section CT, 92% (95% CI: 87%, 97%) at 16-section CT, 56% (95% CI: 46%, 66%) at 1.5-T MR imaging, and 55% (95% CI: 45%, 65%) at 3.0-T MR imaging. The detection of polyps at least 4 mm in diameter was not influenced by the modality or radiation dose (sensitivity of 100%). CT performed in low-dose mode depicted all polyps with a diameter of at least 3 mm. Polyps smaller than 3 mm in diameter were detected with a sensitivity of 7.5% (1.5-T MR imaging), 22.5% (3.0-T MR imaging), and 20% (low-dose CT); detection rates were significantly greater (P < .001) with normal-dose CT (four section, 67.5%; 16 section, 82.5%). Increased spatial resolution (with CT) and higher field strength (with MR imaging) had no significant effect on polyp detection.

Conclusion: With both multi–detector row CT and MR imaging, readers detected polyps above the clinically relevant threshold diameter of 6 mm, with similar sensitivities.

© RSNA, 2006




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
A. H. de Vries, H. W. Venema, J. Florie, C. Y. Nio, and J. Stoker
Influence of Tagged Fecal Material on Detectability of Colorectal Polyps at CT: Phantom Study
Am. J. Roentgenol., October 1, 2008; 191(4): W181 - W189.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
I. Yamada, S. Okabe, M. Enomoto, K. Sugihara, N. Yoshino, A. Tetsumura, J. Kumagai, and H. Shibuya
Colorectal Carcinoma: In Vitro Evaluation with High-Spatial-Resolution 3D Constructive Interference in Steady-State MR Imaging
Radiology, December 19, 2007; (2007) 2462070128.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2006 by the Radiological Society of North America.