Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2461070200
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pisano, E. D.
Right arrow Articles by Gatsonis, C. A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Pisano, E. D.
Right arrow Articles by Gatsonis, C. A.
(Radiology 2008;246:376-383.)
© RSNA, 2008


Breast Imaging

Diagnostic Accuracy of Digital versus Film Mammography: Exploratory Analysis of Selected Population Subgroups in DMIST1

Etta D. Pisano, MD, R. Edward Hendrick, PhD, Martin J. Yaffe, PhD, Janet K. Baum, MD, Suddhasatta Acharyya, PhD, Jean B. Cormack, PhD, Lucy A. Hanna, MS, Emily F. Conant, MD, Laurie L. Fajardo, MD, Lawrence W. Bassett, MD, Carl J. D'Orsi, MD, Roberta A. Jong, MD, Murray Rebner, MD, Anna N. A. Tosteson, ScD, and Constantine A. Gatsonis, PhD For the DMIST Investigators Group

1 From the Departments of Radiology and Biomedical Engineering, the UNC-Lineberger Comprehensive Cancer Center, and the Biomedical Research Imaging Center of the University of North Carolina School of Medicine, 101 Manning Dr, Room 515, Old Infirmary Building, Chapel Hill, NC 27599-7510 (E.D.P.); Center for Statistical Sciences, Brown University, Providence, RI (S.A., J.B.C., L.A.H., C.A.G.); Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill (R.E.H.); Departments of Medical Imaging (M.J.Y., R.A.J.) and Medical Biophysics (M.J.Y.), University of Toronto, Toronto, Ontario, Canada; Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass (J.K.B.); Department of Radiology, University of California-Los Angeles, Los Angeles, Calif (L.W.B.); Department of Radiology, University of Pennsylvania, Philadelphia, Pa (E.F.C.); Department of Radiology, University of Iowa, Iowa City, Iowa (L.L.F.); Department of Radiology, William Beaumont Hospital, Royal Oak, Mich (M.R.); Department of Radiology, Emory University, Atlanta, Ga (C.J.D.); and Center for the Evaluative Clinical Sciences, Norris Cotton Cancer Center, Dartmouth Medical School, Lebanon, NH (A.N.A.T.). The remaining members of the DMIST Investigators Group are listed in the Appendix. Received January 30, 2007; revision requested April 11; revision received May 23; final version accepted July 2. Address correspondence to E.D.P. (e-mail: etta_pisano{at}med.unc.edu).

Purpose: To retrospectively compare the accuracy of digital versus film mammography in population subgroups of the Digital Mammographic Imaging Screening Trial (DMIST) defined by combinations of age, menopausal status, and breast density, by using either biopsy results or follow-up information as the reference standard.

Materials and Methods: DMIST included women who underwent both digital and film screening mammography. Institutional review board approval at all participating sites and informed consent from all participating women in compliance with HIPAA was obtained for DMIST and this retrospective analysis. Areas under the receiver operating characteristic curve (AUCs) for each modality were compared within each subgroup evaluated (age < 50 vs 50–64 vs ≥ 65 years, dense vs nondense breasts at mammography, and pre- or perimenopausal vs postmenopausal status for the two younger age cohorts [10 new subgroups in toto]) while controlling for multiple comparisons (P < .002 indicated a significant difference). All DMIST cancers were evaluated with respect to mammographic detection method (digital vs film vs both vs neither), mammographic lesion type (mass, calcifications, or other), digital machine type, mammographic and pathologic size and diagnosis, existence of prior mammographic study at time of interpretation, months since prior mammographic study, and compressed breast thickness.

Results: Thirty-three centers enrolled 49 528 women. Breast cancer status was determined for 42 760 women, the group included in this study. Pre- or perimenopausal women younger than 50 years who had dense breasts at film mammography comprised the only subgroup for which digital mammography was significantly better than film (AUCs, 0.79 vs 0.54; P = .0015). Breast Imaging Reporting and Data System–based sensitivity in this subgroup was 0.59 for digital and 0.27 for film mammography. AUCs were not significantly different in any of the other subgroups. For women aged 65 years or older with fatty breasts, the AUC showed a nonsignificant tendency toward film being better than digital mammography (AUCs, 0.88 vs 0.70; P = .0025).

Conclusion: Digital mammography performed significantly better than film for pre- and perimenopausal women younger than 50 years with dense breasts, but film tended nonsignificantly to perform better for women aged 65 years or older with fatty breasts.

© RSNA, 2008




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
C. B. Hruska, S. W. Phillips, D. H. Whaley, D. J. Rhodes, and M. K. O'Connor
Molecular Breast Imaging: Use of a Dual-Head Dedicated Gamma Camera to Detect Small Breast Tumors
Am. J. Roentgenol., December 1, 2008; 191(6): 1805 - 1815.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. L. Hixson Sr, R. E. Hendrick, E. D. Pisano, M. J. Yaffe, and C. A. Gatsonis
A Limitation of ACRIN DMIST
Radiology, August 1, 2008; 248(2): 702 - 703.
[Full Text] [PDF]


Home page
RadiologyHome page
D. B. Kopans, E. D. Pisano, S. Acharyya, R. E. Hendrick, M. J. Yaffe, E. F. Conant, L. L. Fajardo, L. W. Bassett, J. K. Baum, and C. A. Gatsonis
DMIST Results: Technologic or Observer Variability?
Radiology, August 1, 2008; 248(2): 703 - 704.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2008 by the Radiological Society of North America.