Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print February 21, 2008, 10.1148/radiol.2471070420
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2471070420v1
247/1/88    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Elmståhl, B.
Right arrow Articles by Almén, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Elmståhl, B.
Right arrow Articles by Almén, T.
(Radiology 2008;247:88-97.)
© RSNA, 2008


Experimental Studies

Iodixanol 320 Results in Better Renal Tolerance and Radiodensity than Do Gadolinium-based Contrast Media: Arteriography in Ischemic Porcine Kidneys1

Barbara Elmståhl, MD, PhD, Ulf Nyman, MD, PhD, Peter Leander, MD, PhD, Klaes Golman, PhD, Chun-Ming Chai, MD, PhD, Derek Grant, PhD, Richard Doughty, PhD, Rikard Pehrson, PhD, Jonas Björk, PhD, and Torsten Almén, MD, PhD

1 From the Departments of Diagnostic Radiology (B.E., P.L., T.A.) and Experimental Research (C.M.C.), and Competence Center for Clinical Research (J.B.), Malmö University Hospital, Lund University, SE-205 02 Malmö, Sweden; Department of Radiology, Lasarettet Trelleborg, Trelleborg, Sweden (U.N.); GE Healthcare Biosciences, Medeon, Malmö, Sweden (K.G., R.P.); and Department of Safety Preclinical Sciences, Biology, GE Healthcare Biosciences, Oslo, Norway (D.G., R.D.). Received March 6, 2007; revision requested May 14; revision received June 25; accepted July 19; final version accepted September 24. Address correspondence to B.E. (e-mail: barbara.elmstahl{at}med.lu.se).

Purpose: To prospectively compare nephrotoxicity and radiodensity of plasma hyperosmotic gadolinium chelates (attenuation-osmotic ratio of 1:1) with those of plasma iso-osmotic iodine-based contrast media (attenuation-osmotic ratio of 3:1 or 6:1) after renal arteriography in ischemic porcine kidneys.

Materials and Methods: The local animal care committee approved this study. The following contrast media were used: (a) iodixanol (150 mg of iodine per milliliter and 320 mg I/mL, 0.29 osm/kg H2O), (b) iopromide (150 mg I/mL, 0.34 osm/kg), (c) 0.5 mol/L gadodiamide (0.78 osm/kg), and (d) 1.0 mol/L gadobutrol (1.6 osm/kg). After left-sided nephrectomy, contrast media (3 mL per kilogram of body weight) were injected (20 mL/min) in a noncrossover design into the right renal artery of pigs during a 10-minute ischemic period. There were eight pigs in each group and one group for each contrast medium. We compared histomorphology, radiographic contrast medium excretion, subjective radiodensity of nephrograms (70 kVp) at the end of injection, and contrast medium plasma half-life elimination times 1–3 hours after injection. Longer elimination times resulted in lower glomerular filtration rates.

Results: Gadobutrol caused extensive tubular necrosis and moderate glomerular necrosis; gadodiamide and iopromide, minimal to mild tubular necrosis; and iodixanol, no necrosis. Gadobutrol was the only contrast medium to show no sign of excretion, and its plasma half-life elimination time (median, 1103 minutes; P < .001) was significantly longer than that of other contrast agents. Gadodiamide had a significantly longer plasma half-life elimination time (median, 209 minutes; P = .01) than did iodine-based contrast media (median, 136–142 minutes). The 320 mg I/mL dose of iodixanol had the highest radiodensity, whereas gadodiamide had the lowest radiodensity. The radiodensity of the 320 mg I/mL dose of iodixanol was greater than that of the 150 mg I/mL dose of iodixanol, which was equal to the radiodensities of the 150 mg I/mL dose of iopromide and 1.0 mol/L gadobutrol, which in turn were greater than that of 0.5 mol/L gadodiamide.

Conclusion: Plasma iso-osmotic iodine-based contrast media used at commercially available concentrations have superior attenuation and nephrotoxic profiles compared with equal volumes of hyperosmotic nonionic 0.5–1.0 mol/L gadolinium-based contrast media when performing renal arteriographic procedures.