Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published online before print May 5, 2008, 10.1148/radiol.2481071156

(Radiology 2008;248:124.)

A more recent version of this article appeared on July 1, 2008
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow All Versions of this Article:
2481071156v1
248/1/124    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Sugita, R.
Right arrow Articles by Takahashi, S.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sugita, R.
Right arrow Articles by Takahashi, S.
© RSNA, 2008

Gastrointestinal Imaging

Cystic Artery and Cystic Duct Assessment with 64–Detector Row CT before Laparoscopic Cholecystectomy1

Reiji Sugita, MD, Tetsuro Yamazaki, MD, Naotaka Fujita, MD, Tsuyoshi Naitoh, MD, Masao Kobari, MD, and Shoki Takahashi, MD

1 From the Departments of Radiology (R.S.), Gastroenterology (N.F.), and Surgery (T.N., M.K.), Sendai City Medical Center, 5-22-1 Tsurugaya, Miyangino-ku, Sendai, Miyagi 983-0824, Japan; Department of Radiology, Nippon Telephone and Telegraph East Tohoku Hospital, Sendai, Miyagi, Japan (T.Y.); and Department of Diagnostic Radiology, Tohoku University, Graduate School of Medicine, Sendai, Miyagi, Japan (S.T.). Received July 3, 2007; revision requested August 30; revision received November 2; accepted January 14, 2008; final version accepted January 31. Address correspondence to R.S. (e-mail: rsugita{at}openhp.or.jp).

Purpose: To retrospectively assess 64–detector row computed tomography (CT) in the preoperative depiction of the cystic duct and cystic arteries in and around the Calot triangle.

Materials and Methods: Institutional review board approval was obtained, with waiver of informed consent. A total of 245 consecutive patients (133 men, 112 women), including 48 patients who subsequently underwent cholecystectomy, were examined. Two independent observers evaluated the CT data set on the basis of axial sections, coronal and sagittal multiplanar reformations, and three-dimensional volume rendering. The relationship between the cystic arteries and the Calot triangle—which is bordered by the undersurface of the liver, common hepatic duct, and cystic duct—was also evaluated, and each patient was classified on the basis of the origin of the cystic arteries and the course to the Calot triangle. Statistical analysis was performed, and percentages and confidence intervals were calculated.

Results: The cystic arteries were delineated in 234 of the 245 patients. Both the Calot triangle and the cystic arteries were delineated in 223 patients. One cystic artery was seen in the Calot triangle in 173 patients, and two cystic arteries were seen in the Calot triangle in 12. One artery in the Calot triangle with accessory arteries from different origins outside the Calot triangle was seen in 18 patients, and no cystic artery was identified in 20. Cystic arteries were seen in 42 (92%; 95% confidence interval: 87%, 98%) of the 48 patients who subsequently underwent cholecystectomy. The relationship between the cystic arteries and the Calot triangle was in agreement with the surgical records for all patients.

Conclusion: The configuration of the cystic duct and cystic arteries can be depicted preoperatively with 64–detector row CT in patients scheduled to undergo cholecystectomy.