Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print April 3, 2003, 10.1148/radiol.2272020476
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2272020476v1
227/2/549    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by March, D. E.
Right arrow Articles by Makari-Judson, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by March, D. E.
Right arrow Articles by Makari-Judson, G.
(Radiology 2003;227:549-555.)
© RSNA, 2003


Breast Imaging

Breast Masses: Removal of All US Evidence during Biopsy by Using a Handheld Vacuum-assisted Device—Initial Experience1

David E. March, MD, Bret F. Coughlin, MD, Ruth B. Barham, MPH, Robert A. Goulart, MD, Stephen V. Klein, MD, Martin E. Bur, MD, James L. Frank, MD and Grace Makari-Judson, MD

1 From the Department of Radiology (D.E.M., B.F.C., S.V.K.), Baystate Comprehensive Breast Center/Regional Cancer Program (R.B.B.), Department of Pathology (R.A.G., M.E.B.), Department of Surgery (J.L.F.), and Division of Hematology and Oncology (G.M.J.), Baystate Medical Center, 759 Chestnut St, Springfield, MA 01199. From the 2001 RSNA scientific assembly. Received April 25, 2002; revision requested June 21; revision received August 16; accepted September 30. Supported by an RSNA Seed Grant and by the Rays of Hope charitable fund. Address correspondence to D.E.M.


    ABSTRACT
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
PURPOSE: To assess the effects of removal of all ultrasonographic (US) evidence of breast lesions by using a vacuum-assisted biopsy (VAB) device.

MATERIALS AND METHODS: Thirty-four women with breast masses underwent US-guided biopsy with an 11-gauge VAB device, with which removal of all evidence of the lesion was attempted. Histologic findings were compared with results of surgery and follow-up imaging. Patient tolerance and perceptions of the procedure and the ability of the procedure to eliminate a palpable finding were evaluated with questionnaires and findings at follow-up physical examination.

RESULTS: The biopsy protocol was completed in all cases. Twenty-six benign lesions (76%) and eight malignancies (24%) were diagnosed. After VAB, 10 patients (29%) underwent surgery on the basis of histologic findings of invasive carcinoma (n = 7), ductal carcinoma in situ (n = 1), lobular neoplasia (n = 1), or atypical ductal hyperplasia (n = 1). VAB resulted in complete excision of four of 10 lesions: two of eight malignancies and two of two benign lesions. Among 21 patients with benign lesions who underwent 6-month follow-up imaging, eight (38%) had a definite residual mass. At 6-month follow-up examination, VAB was seen to have eliminated the palpable abnormality in seven (88%) of eight patients with initially palpable benign masses. Thirty-two patients (94%) described no or mild pain during biopsy, and 33 patients (97%) rated care as excellent.

CONCLUSION: After removal of all US evidence of breast masses with a VAB device, there was a substantial probability that residual lesion that was not visualized during the procedure would later be found at surgery or follow-up imaging. A palpable mass (<=1.2 cm in mean diameter) was eliminated in 88% of cases, and patient tolerance and perceptions of the procedure were favorable.

© RSNA, 2003

Index terms: Breast, biopsy, 00.1261, 00.1262 • Breast neoplasms, localization, 00.12985 • Breast neoplasms, therapy, 00.1262 • Breast neoplasms, US, 00.1298, 00.12985 • Ultrasound (US), guidance, 00.12985


    INTRODUCTION
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
Breast biopsy with an automated device and stereotactic guidance was described by Parker et al in 1990 (1), and large-core biopsy with ultrasonographic (US) guidance was reported in 1993 (2). Directional vacuum-assisted biopsy (VAB) technology, introduced in 1996, allows for faster acquisition of larger tissue volumes than is possible with an automated device (3). The use of US-guided VAB for diagnosis, and, in some cases, removal of all US evidence of lesions has been reported (46). We have had experience in using an 11-gauge handheld VAB device in the biopsy of undiagnosed breast masses, and we have attempted to use this device to remove all US evidence of lesions while obtaining material for histologic diagnosis. Information on the use of the VAB device in this manner is important for evaluating potential applications of the device and for educating patients about expectations and outcomes of the procedure.


    MATERIALS AND METHODS
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
Patients
This study was conducted during a 15-month period (August 2000 through October 2001). To be included in the study, women had to have been referred to one of two outpatient facilities (Baystate Comprehensive Breast Center, Radiology and Imaging outpatient imaging facility) for US-guided biopsy of single-breast lesions that were well visualized at US and located at least 0.5 cm from the skin surface and pectoralis margin and at least 2.0 cm from the nipple. The sample notch on the VAB probe measures 1.9 cm in length, and only patients with masses measuring less than or equal to 1.2 cm in mean diameter at US were included to allow the entire diameter of the lesion—including its margin and adjacent tissue—to be included in the biopsy specimens.

During this prospective study, 348 patients were referred for possible US-guided biopsy, and 346 were screened by our research associate (R.B.B.) for possible enrollment. The research associate, who consulted with a participating radiologist (D.E.M., B.F.C., or S.V.K.) when necessary, reviewed US images obtained in potential participants and performed measurements (length, width, height) of the lesion and of its distance from the skin surface and chest wall to determine patient eligibility for the study.

Two patients were not screened because they were scheduled for and underwent biopsy before the research associate could review the cases and contact the patients about possible participation. Fifty-seven screened patients (16%) met the study requirements and were offered inclusion; 38 (67%) of the eligible patients chose to participate. Four patients who agreed to participate were excluded because their lesions represented complex cysts that were aspirated; this resulted in a final study population of 34 women.

Descriptions of the shape and margin characteristics of masses on the basis of their combined mammographic and sonographic features were recorded before biopsy by one of three radiologist authors (D.E.M., B.F.C., or S.V.K.), who used mammography terminology previously described by the American College of Radiology (7). The mean age of participating patients was 50 years (range, 27–84 years). The institutional review board of Baystate Medical Center reviewed and approved this study, and participating patients read and signed a separate informed consent form.

Biopsy Procedure and Review of Histologic Findings
The biopsy protocol used in this study involves removal of a substantially larger tissue volume than is our usual practice. Biopsy procedures were performed by one of the three participating radiologists (D.E.M., B.F.C., or S.V.K.) with an 11-gauge biopsy device (Ethicon Endo-Surgery, Cincinnati, Ohio; U.S. Food and Drug Administration approval for use in diagnosis, 1999). This handheld vacuum-assisted device is used for freehand biopsy with US guidance. With the device, one can apply suction through the biopsy probe to draw tissue into a sample notch, separate a sample with a rotating cutter, and transport the specimen to a collection chamber for removal. Directional sampling is achieved by manually rotating the probe at the biopsy site. Identical US units (Ultramark 9 HDI; Philips Medical Systems, Bothell, Wash) equipped with 5–10-MHz transducers were used to guide the procedures.

US was used to localize the mass and to enable measurement of the distance from the skin surface to the anterior margin of the lesion and the distance from the deep margin of the lesion to the anterior pectoralis margin. Anesthetization of the skin and deeper tissues leading to and around the lesion was achieved with administration of a mean of 8 mL of buffered 1% lidocaine and a mean of 9 mL of 1% lidocaine and epinephrine in a 1:100,000 mixture, respectively. With US guidance, the probe was positioned deep to the lesion through a small skin incision. A distance of at least 0.2 cm was documented at US between the open sampling notch and the deep margin of the lesion to allow for inclusion of the deep margin during biopsy. Samples were obtained between the 8-o’clock and 4-o’clock locations, rotating through the 12-o’clock position. Sampling of tissue deep to the probe (from the 5-o’clock to the 7-o’clock positions), the process of which would have been obscured by acoustic shadowing from the probe and required that the sampling notch be directed toward the chest wall, was thereby avoided. An attempt was made to remove all evidence of the target lesion with continuous US guidance.

After biopsy, US was performed in multiple planes, with and without application of suction to collapse the biopsy cavity, so that we could assess for the presence of residual mass. Any visible remaining lesion was removed at that time. A clear-probe mode on the VAB unit permits the application of pulsed suction through the biopsy probe for the removal of residual tissue fragments. This technique was used, and any removed tissue was placed in formalin with the lesion samples. With the same biopsy probe, a second series of core samples was then obtained from the margins of the biopsy cavity. These samples were removed to enable determination of whether margin sampling is an accurate means of predicting the presence or absence of residual target lesion. To accomplish this, the biopsy probe was rotated within the cavity; the directional capability of the device enabled sampling of tissue from different portions of the cavity wall. Samples were obtained from between the 8-o’clock and 4-o’clock locations, rotating through the 12-o’clock position. The cavity was again suctioned by using the clear-probe mode, and any retrieved fragments were included with the margin samples. The procedure time (from injection of local anesthetic to removal of the biopsy probe) and number of biopsy passes were recorded by an assisting technologist.

After biopsy, a metallic tissue marker (MicroMark Clip; Ethicon Endo-Surgery) was deployed through the biopsy probe, the probe was removed, and hemostasis was achieved by means of manual compression. The incision was closed with adhesive strips, and a sterile pressure dressing was applied. Patients then underwent unilateral mammography, which is routine in our practice after clip placement. Specimen radiography of biopsy samples was performed when the target lesion contained calcifications. Patients were instructed to apply an ice pack for the remainder of the day, to avoid strenuous activities, and to take acetaminophen if they experienced discomfort.

Histologic slides of tissue taken from the lesion and from the margins were interpreted by one of two experienced breast pathologists (R.A.G., M.E.B.). These pathologists also reviewed histologic material from all patients who underwent subsequent surgical procedures and recorded the size and distribution of any residual target lesion and measured its distance from the edge of the VAB cavity.

Data Analysis
The VAB procedure was considered diagnostically accurate when (a) a specific histologic diagnosis was established that was concordant with the imaging findings, (b) there was no substantial change in diagnosis (ie, no benign or atypical histologic findings at VAB but malignancy diagnosed at excision, and no in situ carcinoma diagnosed at VAB but invasive carcinoma revealed at excision) of lesions that were subsequently excised, and (c) there was no evidence of misdiagnosis at the time of follow-up imaging.

Masses were considered initially palpable if they could be felt by the referring provider, patient, or radiologist before biopsy and were considered impalpable at 6-month follow-up if neither the patient nor the radiologist could palpate the mass. Lesions were considered completely excised at VAB only in patients who underwent subsequent surgical removal of tissue from the biopsy site with no evidence of residual target lesion in the surgical specimen; lesions were considered not completely excised if residual lesion was present in the surgical specimen or at follow-up imaging. The accuracy of margin sampling as a predictor of the presence or absence of residual lesion was evaluated on the basis of comparison with histologic material obtained during subsequent surgery in 10 patients.

Patient Tolerance, Perceptions, Cosmetic Outcome, and Follow-up Imaging
Assessment of patient tolerance and perceptions of the procedure was based on patients’ ability to tolerate completion of the study protocol and on their responses to self-administered questionnaires, which were distributed by the research associate while the radiologist was not present. The first questionnaire was completed after the procedure on the day of biopsy. Patients were asked to rate pain experienced during biopsy (as none, mild, moderate, or severe) and the quality of care received (as excellent, good, fair, or poor). During a follow-up appointment 2–5 days after biopsy, all patients completed a second questionnaire and responded to questions about whether they had taken medication for pain or experienced any bleeding (none, mild, moderate, or severe) and whether the procedure had interfered with their usual daily life (not at all, a little, somewhat, or a lot). One of the three radiologist authors examined the patient. Any palpable abnormality at the biopsy site was measured, and any ecchymosis or change in the breast contour was noted.

Patients who did not undergo surgery and who returned for follow-up approximately 6 months after biopsy were administered a third questionnaire to determine their level of satisfaction (very satisfied, satisfied, or not at all satisfied) regarding how the biopsy site appeared and felt, whether they would recommend the procedure to someone in a similar situation, and whether they could feel any abnormality at the biopsy site. Patients underwent physical examination of the biopsy site performed by one of two radiologist authors (D.E.M., S.V.K.) (17 of 21 patients) or by one of two different radiologists (four of 21 patients; two patients each). The examining radiologist inspected the biopsy site for visible scar, which was measured, and for any skin retraction or other contour abnormality. Physical examination of the area was performed to assess for palpable abnormalities.

Patients who returned at 6 months also underwent imaging to evaluate the area of biopsy. All patients underwent unilateral mammography except one—a 28-year-old woman who had undergone VAB of a palpable mass that was mammographically occult—and all patients underwent US examination of the biopsy region. These studies were interpreted by the same radiologist who performed the physical examinations. The radiologist scanned the area of biopsy in each case and compared the mammographic and real-time US findings with the appearance and location of the mass on mammograms and US images obtained before biopsy.


    RESULTS
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
All patients (n = 34) completed the study protocol, with removal of all US evidence of the lesion. The mean lesion diameter was 0.7 cm (range, 0.4–1.2 cm), the mean distance from the skin surface to the lesion was 0.9 cm (range, 0.5–1.7 cm), the mean distance from the deep margin of the lesion to the chest wall was 0.9 cm (range, 0.5–2.2 cm), and the mean biopsy time was 30 minutes (range, 16–54 minutes). Twenty-six benign lesions (76%) and eight malignancies (24%) were diagnosed. A mean of 29 samples were obtained from each lesion (range, 10–70), and a mean of five samples were obtained from the margins (four samples in one patient, five samples in 30, and six samples in three). Specimen radiography was performed in three cases in which the lesion contained calcifications, and inclusion of calcifications in the biopsy specimens was confirmed in each case. After VAB, 10 patients (29%) underwent surgery on the basis of histologic findings of invasive carcinoma (n = 7), ductal carcinoma in situ (DCIS) (n = 1), pseudoangiomatous stromal hyperplasia with lobular neoplasia (n = 1), or fibroadenoma with atypical ductal hyperplasia (n = 1). One patient with a diagnosis of fibroadenoma and a single focus of atypical ductal hyperplasia in the adjacent tissue declined surgical excision and underwent 6-month follow-up imaging.

Diagnostic Accuracy
For each lesion, a specific histologic diagnosis concordant with the imaging findings was established. Twenty-four patients had benign lesions (Table 1); 21 of these patients underwent 6-month follow-up imaging. Surgery was performed in 10 patients for eight malignancies and two atypical lesions that were diagnosed at VAB (Table 2). Among those patients who underwent subsequent surgical excision, there were no substantial changes in the histologic diagnosis established at VAB (Table 2). One patient with fibroadenoma and atypical ductal hyperplasia at VAB had no malignancy or atypical ductal hyperplasia at excision. One patient with pseudoangiomatous stromal hyperplasia and lobular neoplasia at VAB had no DCIS or invasive carcinoma at excision. One patient with DCIS at VAB had no invasive carcinoma at excision. One patient with invasive carcinoma only at VAB had a focus of DCIS at excision, in addition to invasive carcinoma. The patient with invasive carcinoma with ductal and lobular features and DCIS at VAB had only residual invasive tumor at mastectomy. Six-month follow-up imaging was performed in 21 patients with benign lesions and revealed no findings that indicated potential misdiagnosis and no indications for further intervention.


View this table:
[in this window]
[in a new window]

 
TABLE 1. Histologic Findings at VAB in 24 Patients Who Did Not Subsequently Undergo Surgery

 

View this table:
[in this window]
[in a new window]

 
TABLE 2. Comparison of Imaging Features with Histologic Findings at VAB and Findings at Subsequent Surgery in 10 Patients

 
Excisional Capability and Accuracy of Margin Sampling in Predicting Complete Excision
The VAB procedure enabled complete removal of four of 10 lesions in women who subsequently underwent surgery (Table 2), including two of eight malignancies and two of two benign lesions. The sizes, shapes, and margin characteristics of the lesions are described in Table 2. Residual carcinoma in six incompletely removed malignancies extended a mean of 1.2 cm from the edge of the biopsy cavity (range, 0.1–4.0 cm). In five of these patients, the remaining tumor was found in small foci or a rim of tissue, and extended 0.1–1.2 cm (mean, 0.6 cm) from the cavity edge. The malignancies excised at VAB measured 0.5 and 0.7 cm in mean diameter at US and represented infiltrating carcinoma with ductal and lobular features (histologic grade I) and infiltrating ductal carcinoma (histologic grade III) with focal DCIS, respectively.

Among 21 patients with benign lesions who returned for 6-month follow-up, eight (38%) had lesions that were not fully excised at VAB and definite residual mass at US (Fig 1), eight (38%) had no evidence of residual lesion at follow-up imaging, and five (24%) had equivocal findings at follow-up imaging (ie, it was uncertain if residual target lesion—versus postbiopsy changes or a different lesion—was present). For the 10 patients who underwent surgery after the VAB procedure, the histologic presence or absence of target lesion in the VAB margin samples correctly predicted the presence or absence of residual target lesion at surgery in four of eight malignancies and two of two benign lesions (Fig 2).



View larger version (192K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1a. Images in a 44-year-old woman with a left breast mass that was discovered at screening mammography. (a) US image obtained before VAB in the radial plane shows a lobulated solid lesion (arrows) of 0.9 cm in mean diameter. All US evidence of the lesion was removed during VAB; the histologic diagnosis was fibroadenoma. (b) Follow-up US image obtained in the radial plane 6 months after biopsy shows a crescentic residual mass (arrows) measuring 0.4 cm in mean diameter that was obscured during the VAB procedure.

 


View larger version (188K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1b. Images in a 44-year-old woman with a left breast mass that was discovered at screening mammography. (a) US image obtained before VAB in the radial plane shows a lobulated solid lesion (arrows) of 0.9 cm in mean diameter. All US evidence of the lesion was removed during VAB; the histologic diagnosis was fibroadenoma. (b) Follow-up US image obtained in the radial plane 6 months after biopsy shows a crescentic residual mass (arrows) measuring 0.4 cm in mean diameter that was obscured during the VAB procedure.

 


View larger version (199K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2a. Images in a 42-year-old woman with a mass with calcifications that was discovered at screening mammography. (a) US image obtained before VAB in the radial plane shows a markedly hypoechoic mass (arrow) of 0.6 cm in mean diameter with angular margins. (b) US image obtained immediately after VAB with the device still inserted shows the biopsy probe (arrows) and no residual mass. (c) Radiograph of the specimens taken from the mass shows calcifications (arrows). The histologic diagnosis was DCIS (intermediate and high grades, solid and cribriform types). (d) Radiograph of five biopsy samples taken from the cavity margins does not reveal calcifications, and no carcinoma was found at histologic examination of these specimens. The excised surgical specimen contained residual DCIS extending up to 0.5 cm from the edge of the VAB cavity.

 


View larger version (176K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2b. Images in a 42-year-old woman with a mass with calcifications that was discovered at screening mammography. (a) US image obtained before VAB in the radial plane shows a markedly hypoechoic mass (arrow) of 0.6 cm in mean diameter with angular margins. (b) US image obtained immediately after VAB with the device still inserted shows the biopsy probe (arrows) and no residual mass. (c) Radiograph of the specimens taken from the mass shows calcifications (arrows). The histologic diagnosis was DCIS (intermediate and high grades, solid and cribriform types). (d) Radiograph of five biopsy samples taken from the cavity margins does not reveal calcifications, and no carcinoma was found at histologic examination of these specimens. The excised surgical specimen contained residual DCIS extending up to 0.5 cm from the edge of the VAB cavity.

 


View larger version (82K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2c. Images in a 42-year-old woman with a mass with calcifications that was discovered at screening mammography. (a) US image obtained before VAB in the radial plane shows a markedly hypoechoic mass (arrow) of 0.6 cm in mean diameter with angular margins. (b) US image obtained immediately after VAB with the device still inserted shows the biopsy probe (arrows) and no residual mass. (c) Radiograph of the specimens taken from the mass shows calcifications (arrows). The histologic diagnosis was DCIS (intermediate and high grades, solid and cribriform types). (d) Radiograph of five biopsy samples taken from the cavity margins does not reveal calcifications, and no carcinoma was found at histologic examination of these specimens. The excised surgical specimen contained residual DCIS extending up to 0.5 cm from the edge of the VAB cavity.

 


View larger version (91K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2d. Images in a 42-year-old woman with a mass with calcifications that was discovered at screening mammography. (a) US image obtained before VAB in the radial plane shows a markedly hypoechoic mass (arrow) of 0.6 cm in mean diameter with angular margins. (b) US image obtained immediately after VAB with the device still inserted shows the biopsy probe (arrows) and no residual mass. (c) Radiograph of the specimens taken from the mass shows calcifications (arrows). The histologic diagnosis was DCIS (intermediate and high grades, solid and cribriform types). (d) Radiograph of five biopsy samples taken from the cavity margins does not reveal calcifications, and no carcinoma was found at histologic examination of these specimens. The excised surgical specimen contained residual DCIS extending up to 0.5 cm from the edge of the VAB cavity.

 
Patient Tolerance and Perceptions
No procedures were terminated before completion of the study protocol due to patient discomfort or complication. On a questionnaire completed immediately after the procedure, pain during biopsy was described as not present (n = 19), mild (n = 13), or moderate (n = 2). No patients described severe pain. Thirty-three patients (97%) rated care as excellent, one (3%) rated it as good, and none rated it as fair or poor.

All 34 patients returned 2–5 days after their procedure to undergo follow-up physical examination and to complete a second questionnaire. Twenty patients (59%) took acetaminophen for discomfort and 14 (41%) took no analgesics. No patients reported bleeding. When asked how much the procedure interfered with their usual daily activities, 16 patients (47%) indicated "not at all;" 14 (41%), "a little;" four (12%), "somewhat;" and none, "a lot." At examination, 24 patients (71%) had ecchymosis, nine (26%) had no visible abnormality aside from the skin incision, and one (3%) had slight skin convexity without ecchymosis at the biopsy site. Twenty-five patients (74%) had no palpable findings in the biopsy region, and nine (26%) had focal palpable hematomas or edematous tissue measuring 2.8 cm in median (mean, 4.0 cm) diameter. These values include outlying data from a patient who developed a large hematoma (discussed below).

Twenty-four patients with benign lesions did not undergo surgery, and 21 (88%) of these 24 patients underwent follow-up imaging and physical examination and completed a third questionnaire approximately 6 months after VAB. Nineteen (90%) of these 21 patients were very satisfied with the appearance of the biopsy area, two (10%) were satisfied, and none was dissatisfied; 16 patients (76%) were very satisfied with how the biopsy area felt, five (24%) were satisfied, and none was dissatisfied. All 21 patients stated that they would recommend this biopsy technique to someone in a similar situation. At clinical examination, four patients (19%) had no visible scarring, and 17 (81%) had minimal scarring (scar length range, 2–9 mm). No patients had skin retraction, concavity, convexity, or other change in breast contour. Among the 13 patients whose lesions were initially impalpable and who underwent 6-month follow-up examination, none described a new palpable finding at the biopsy site. In one of these patients, the examining radiologist noted palpable scar tissue in the region of biopsy. Mammography (n = 20) and US (n = 21) showed no evidence of chronic fluid collection or other complications in any of the 21 patients who underwent follow-up imaging and physical examination.

Ability to Eliminate a Palpable Finding
The lesion was initially palpable in 10 (29%) of 34 patients, including two patients with malignant and eight with benign pathologic findings. All eight patients with benign lesions returned at approximately 6 months, and there was no residual palpable mass felt by the patient or radiologist in seven (88%) of these patients (Fig 3). One patient, who had no residual palpable mass, did describe a change in the texture of the breast at the biopsy site.



View larger version (159K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3a. (a) Mediolateral oblique mammogram obtained before VAB in a 43-year-old woman with a palpable left breast mass (arrow) of 1.2 cm in mean diameter. (b) US image obtained during VAB demonstrates the remaining visible portion of the mass (arrows); this portion was subsequently removed with the biopsy probe (arrowheads). (c) Mediolateral oblique mammogram obtained after the procedure shows a biopsy cavity (arrows) with no residual mass. A metallic clip has been placed at the biopsy site. The histologic diagnosis was fibroadenoma. At 6-month follow-up (results not shown) there was no residual palpable mass; however, a small residual mass of 0.5 cm in mean diameter was visible at US.

 


View larger version (158K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3b. (a) Mediolateral oblique mammogram obtained before VAB in a 43-year-old woman with a palpable left breast mass (arrow) of 1.2 cm in mean diameter. (b) US image obtained during VAB demonstrates the remaining visible portion of the mass (arrows); this portion was subsequently removed with the biopsy probe (arrowheads). (c) Mediolateral oblique mammogram obtained after the procedure shows a biopsy cavity (arrows) with no residual mass. A metallic clip has been placed at the biopsy site. The histologic diagnosis was fibroadenoma. At 6-month follow-up (results not shown) there was no residual palpable mass; however, a small residual mass of 0.5 cm in mean diameter was visible at US.

 


View larger version (154K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3c. (a) Mediolateral oblique mammogram obtained before VAB in a 43-year-old woman with a palpable left breast mass (arrow) of 1.2 cm in mean diameter. (b) US image obtained during VAB demonstrates the remaining visible portion of the mass (arrows); this portion was subsequently removed with the biopsy probe (arrowheads). (c) Mediolateral oblique mammogram obtained after the procedure shows a biopsy cavity (arrows) with no residual mass. A metallic clip has been placed at the biopsy site. The histologic diagnosis was fibroadenoma. At 6-month follow-up (results not shown) there was no residual palpable mass; however, a small residual mass of 0.5 cm in mean diameter was visible at US.

 
Two patients experienced complications that affected care. The first patient, who had a diagnosis of fibroadenoma, developed an erythematous cutaneous abnormality measuring 1.5 cm in diameter at the incision site. She was referred to the wound care clinic, and a diagnosis of dermal necrosis without infection was rendered. With topical treatment, the wound healed completely 6 weeks after biopsy. Possible explanations for this complication include underlying illness (rheumatoid arthritis, hepatitis C), necrosis caused by epinephrine injection before biopsy, epidermal injury caused by premature removal of the adhesive strips, or a combination of these factors. The second complication, in a patient with a diagnosis of carcinoma, was a large (11-cm) hematoma that developed while the patient was undergoing postprocedure mammography to assess clip placement. The patient had experienced no unusual bleeding or hematoma formation during or immediately after biopsy and had no known coagulopathy. The hematoma regressed spontaneously; however, surgical treatment of the patient’s malignancy was delayed until 6 weeks after VAB.


    DISCUSSION
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
The increasing use of mammographic screening has led to the detection of smaller, earlier-stage malignancies (8), and there has been acceptance of less invasive diagnostic and treatment options (811). Concurrently, since the introduction of breast core biopsy, vacuum-assisted and large-bore cannula devices capable of removing larger tissue volumes have been developed (3). These trends have led to reports describing elimination of all imaging evidence of breast lesions during percutaneous biopsy (4,5) and to speculation that the capability for percutaneous excision of some lesions may have been attained (12,13).

However, the removal of all imaging evidence of a lesion by using available percutaneous biopsy methods with US or stereotactic guidance has not been shown to consistently indicate complete histologic excision. Parker et al (4) reported removal of all imaging evidence of 88% of lesions during 11-gauge US-guided biopsy, with one (5.5%) of 18 infiltrating carcinomas revealed at subsequent surgery to have been completely excised. Perez-Fuentes et al (5) removed all US evidence of 88.6% of lesions, including 10 (71%) of 14 cancers. In their study, subsequent surgical findings confirmed histologic excision of five (50%) of 10 cancers in which no residual abnormality was revealed at US after VAB. Liberman et al found that removal of all mammographic evidence of malignant lesions during stereotactic biopsy resulted in complete histologic excision of eight (35%) of 23 infiltrating carcinomas (14) and four (27%) of 15 infiltrating and in situ carcinomas (15). Use of a large-bore cannula for biopsy with stereotactic guidance has also been found to be unreliable as an excisional technique, with 23 (85.2%) of 27 malignancies in one study (16) having positive margins.

In our series, all US evidence of the target lesions, as visualized on the day of biopsy, was removed in all 34 study patients. However, incomplete excision (revealed at histologic examination of the final surgical specimen) was proved in six (60%) of 10 patients who underwent surgery, and a smaller residual mass was visualized in eight (38%) of 21 patients with benign lesions at 6-month follow-up imaging. It is therefore apparent that the complete excision of some masses was hindered by the loss of visualization of the remaining portion of the lesion during and immediately after VAB owing to the presence of local anesthetic, edema, blood, and/or air, which made the true extent of the lesion difficult to determine. Similar experiences during US-guided VAB have been described (6,17), and we believe that obscuration of the residual portion of lesions was a major obstacle to our ability to more consistently excise entire masses.

In five of the six patients in this study with malignancies that were incompletely excised at VAB, the remaining tumor extended 0.1–1.2 cm (mean, 0.6 cm) from the cavity edge. The thickness range of the residual tumors in our study is similar to thickness ranges of tumors that have been successfully necrosed in early studies of radio-frequency and laser ablation of breast cancers (18,19). The inability of mammography and US to reveal the true extent of a lesion was a limiting factor in at least one patient in our series; this patient had infiltrating lobular carcinoma, which was visualized as a 0.4-cm mass at mammography and US but was revealed at surgery to be multifocal, extending approximately 4.0 cm from the edge of the VAB cavity. Magnetic resonance (MR) imaging can help define the extent of breast carcinoma more accurately than can mammography and US in some patients (20,21), and its potential applications in breast cancer treatment have been described (22). If percutaneous treatment methods for breast cancer are to be developed, tumor ablation and MR imaging before and after treatment would be potential areas for future study.

Results of our technique of sampling the cavity margins after VAB accurately reflected completeness of excision in six of 10 patients. The inaccurate results may be due to noncontiguous sampling, presence of lesion proximal or distal to the sampling notch, protrusions of tumor into the tissues adjacent to the biopsy cavity, presence of discrete islands of tumor distant from the target lesion, or to a combination of these factors.

In our small series, we found that a palpable finding was removed in seven of eight patients and that VAB offers an option for percutaneous diagnosis with potential elimination of a palpable mass, which may be a desirable outcome for some women (23).

Two patients (6%) developed complications from VAB in this study. This rate is in the range of 1.1%–10% that has been reported by other investigators for 11-gauge US-guided VAB (46,24) and is higher than complication rates of less than 1% that have been reported for US-guided breast biopsy with a 14-gauge automated device (25,26) and complication rates of less than 2% that have been reported for stereotactic VAB (27,28). Reports of complications from breast biopsy performed with a large-bore cannula device have ranged from 0% to 20.8% (12,29,30).

In summary, US-guided VAB with removal of all evidence of breast lesions is technically feasible and diagnostically accurate but does not reliably result in the excision of benign or malignant masses. The procedure eliminates a small palpable finding in the large majority of cases. Although two complications occurred in this small series, overall patient tolerance and perceptions of the procedure were favorable.


    ACKNOWLEDGMENTS
 
We thank the technologists in the breast intervention programs at the Baystate Comprehensive Breast Center and the Radiology and Imaging outpatient imaging facility for their contributions to this study.


    FOOTNOTES
 
Abbreviations: DCIS = ductal carcinoma in situ, VAB = vacuum-assisted biopsy

Author contributions: Guarantors of integrity of entire study, D.E.M., R.B.B.; study concepts and design, D.E.M., B.F.C.; literature research, R.B.B., D.E.M.; clinical studies, D.E.M., B.F.C., S.V.K.; data acquisition, R.B.B., R.A.G., M.E.B.; data analysis/interpretation, D.E.M.; manuscript preparation, D.E.M., R.B.B.; manuscript definition of intellectual content, D.E.M.; manuscript editing and revision/review, all authors; manuscript final version approval, D.E.M.


    REFERENCES
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 

  1. Parker SH, Lovin JD, Jobe WE, et al. Stereotactic breast biopsy with a biopsy gun. Radiology 1990; 176:741-747.[Abstract/Free Full Text]
  2. Parker SH, Jobe WE, Dennis MA, et al. US-guided automated large-core breast biopsy. Radiology 1993; 187:507-511.[Abstract/Free Full Text]
  3. Burbank F, Parker SH, Fogarty TJ. Stereotactic breast biopsy: improved tissue harvesting with the Mammotome. Am Surg 1996; 63:738-744.
  4. Parker SH, Klaus AJ, McWey PJ, et al. Sonographically guided directional vacuum-assisted breast biopsy using a handheld device. AJR Am J Roentgenol 2001; 177:405-408.[Abstract/Free Full Text]
  5. Perez-Fuentes JA, Longobardi IR, Acosta VF, Marin CE, Liberman L. Sonographically guided directional vacuum-assisted breast biopsy: preliminary experience in Venezuela. AJR Am J Roentgenol 2001; 177:1459-1463.[Abstract/Free Full Text]
  6. Simon JR, Kalbhen CL, Cooper RA, Flisak ME. Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results. Radiology 2000; 215:694-697.[Abstract/Free Full Text]
  7. American College of Radiology. Breast imaging reporting and data system (BI-RADS) 3rd ed. Reston, Va: American College of Radiology, 1998.
  8. Cady B, Stone MD, Schuler JG, Thakur R, Wanner MA, Lavin PT. The new era in breast cancer. Arch Surg 1996; 131:301-308.[Abstract]
  9. Liberman L, Cody HS. Percutaneous biopsy and sentinel lymphadenectomy: minimally invasive diagnosis and treatment of nonpalpable breast cancer. AJR Am J Roentgenol 2001; 177:887-891.[Abstract/Free Full Text]
  10. NIH consensus conference. Treatment of early-stage breast cancer. JAMA 1991; 265:391-395.[CrossRef][Medline]
  11. March DE, Raslavicus A, Coughlin BF, Klein SV, Makari-Judson G. Use of breast core biopsy in the United States: results of a national survey. AJR Am J Roentgenol 1997; 169:697-701.[Abstract/Free Full Text]
  12. Bloomston M, D’Angelo P, Galliano D, Butler J, Dean R, Rosemurgy AS. One hundred consecutive advanced breast biopsy instrumentation procedures: complications, costs, and outcome. Ann Surg Oncol 1999; 6:195-199.[Abstract]
  13. D’Angelo PC, Galliano DE, Rosemurgy AS. Stereotactic excisional breast biopsies using the advanced breast biopsy instrumentation system. Am J Surg 1997; 174:297-302.[CrossRef][Medline]
  14. Liberman L, Zakowski MF, Avery S, et al. Complete percutaneous excision of infiltrating carcinoma at stereotactic biopsy: how can tumor size be assessed? AJR Am J Roentgenol 1999; 173:1315-1322.[Abstract/Free Full Text]
  15. Liberman L, Dershaw DD, Rosen PP, Morris EA, Abramson AF, Borgen PI. Percutaneous removal of malignant mammographic lesions at stereotactic vacuum-assisted biopsy. Radiology 1998; 206:711-715.[Abstract/Free Full Text]
  16. Smathers RL. Advanced breast biopsy instrumentation device: percentages of lesion and surrounding tissue removed. AJR Am J Roentgenol 2000; 175:801-803.[Abstract/Free Full Text]
  17. Fine RE, Israel PZ, Walker LC, et al. A prospective study of the removal rate of imaged breast lesions by an 11-gauge vacuum-assisted biopsy probe system. Am J Surg 2001; 182:335-340.[CrossRef][Medline]
  18. Jeffrey SS, Birdwell RL, Ikeda DM, et al. Radiofrequency ablation of breast cancer: first report of an emerging technology. Arch Surg 1999; 134:1064-1068.[Abstract/Free Full Text]
  19. Dowlatshahi K, Fan M, Gould VE, Bloom KJ, Ali A. Stereotactically guided laser therapy of occult breast tumors. Arch Surg 2000; 135:1345-1352.[Abstract/Free Full Text]
  20. Boetes C, Mus RDM, Holland R, et al. Breast tumors: comparative accuracy of MR imaging relative to mammography and US for demonstrating extent. Radiology 1995; 197:743-747.[Abstract/Free Full Text]
  21. Esserman L, Hylton N, Yassa L, Barclay J, Frankel S, Sickles E. Utility of magnetic resonance imaging in the management of breast cancer: evidence for improved preoperative staging. J Clin Oncol 1999; 17:110-119.[Abstract/Free Full Text]
  22. Harms SE. Integration of breast magnetic resonance imaging with breast cancer treatment. Top Magn Reson Imaging 1998; 9:79-91.[Medline]
  23. Kopans DB. Breast imaging and the standard of care for the symptomatic patient. Radiology 1993; 187:608-611.[Free Full Text]
  24. Duchesne N, Cote G, Dorion A, Roy M. Ultrasound-guided Mammotome breast biopsies (abstr). AJR Am J Roentgenol 2001; 176(suppl):7.
  25. Parker SH, Burbank F, Jackman RJ, et al. Percutaneous large-core breast biopsy: a multi-institutional study. Radiology 1994; 193:359-364.[Abstract/Free Full Text]
  26. Smith DN, Rosenfield Darling ML, Meyer JE, et al. The utility of ultrasonographically guided large-core needle biopsy: results from 500 consecutive breast biopsies. J Ultrasound Med 2001; 20:43-49.[Abstract]
  27. Burbank F. Stereotactic breast biopsy: comparison of 14- and 11-gauge Mammotome probe performance and complication rates. Am Surg 1997; 63:988-995.[Medline]
  28. Jackman RJ, Marzoni FA, Nowels KW. Percutaneous removal of benign mammographic lesions: comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques. AJR Am J Roentgenol 1998; 171:1325-1330.[Abstract/Free Full Text]
  29. Damascelli B, Frigerio LF, Patelli G, et al. Stereotactic breast biopsy: en bloc excision of microcalcifications with a large-bore cannula device. AJR Am J Roentgenol 1999; 173:895-900.[Abstract/Free Full Text]
  30. Rebner M, Chesbrough R, Gregory N. Initial experience with the advanced breast biopsy instrumentation device. AJR Am J Roentgenol 1999; 173:221-226.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
J.-M. Lee, J. B. Kaplan, M. P. Murray, and L. Liberman
Complete Excision of the MRI Target Lesion at MRI-Guided Vacuum-Assisted Biopsy of Breast Cancer
Am. J. Roentgenol., October 1, 2008; 191(4): 1198 - 1202.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
E. Y. Ko, Y.-A Bae, M.-J. Kim, K. S. Lee, Y. Lee, and L. S. Kim
Factors Affecting the Efficacy of Ultrasound-Guided Vacuum-Assisted Percutaneous Excision for Removal of Benign Breast Lesions
J. Ultrasound Med., January 1, 2008; 27(1): 65 - 73.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. J. Littrup, L. Freeman-Gibb, A. Andea, M. White, K. C. Amerikia, D. Bouwman, T. Harb, and W. Sakr
Cryotherapy for Breast Fibroadenomas
Radiology, January 1, 2005; 234(1): 63 - 72.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2272020476v1
227/2/549    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by March, D. E.
Right arrow Articles by Makari-Judson, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by March, D. E.
Right arrow Articles by Makari-Judson, G.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE